Whole-brain functional and diffusion tensor MRI in human participants with metallic orthodontic braces

Xinyuan Miao, Yuankui Wu, Dapeng Liu, Hangyi Jiang, David Woods, Moshe T. Stern, Nicholas I.S. Blair, Raag D. Airan, Chetan Bettegowda, Keri S. Rosch, Qin Qin, Peter C.M. van Zijl, Jay J. Pillai, Jun Hua

Research output: Contribution to journalArticlepeer-review

3 Scopus citations

Abstract

Background: MRI performed with echo-planar imaging (EPI) sequences is sensitive to susceptibility artifacts in the presence of metallic objects, which presents a substantial barrier for performing functional MRI and diffusion tensor imaging (DTI) in patients with metallic orthodontic material and other head implants. Purpose: To evaluate the ability to reduce susceptibility artifacts in healthy human participants wearing metallic orthodontic braces for two alternative approaches: T2-prepared functional MRI and diffusion-prepared DTI with three-dimensional fast gradient-echo readout. Materials and Methods: In this prospective study conducted from February to September 2018, T2-prepared functional MRI and diffusion-prepared DTI were performed in healthy human participants. Removable dental braces with bonding trays were used so that MRI could be performed with braces and without braces in the same participants. Results were evaluated in regions with strong (EPI dropout regions for functional MRI and the inferior fronto-occipital fasciculus for DTI) and minimal (motor cortex for functional MRI and the posterior limb of internal capsule for DTI) susceptibility artifacts. Signal-to-noise ratio (SNR), contrast-to-noise ratio for functional MRI, apparent diffusion coefficient and fractional anisotropy for DTI, and degree of distortion (quantified with the Jaccard index, which measures the similarity of geometric shapes) were compared in regions with strong or minimal susceptibility effects between the current standard EPI sequences and the proposed alternatives by using paired t test. Results: Six participants were evaluated (mean age 6 standard deviation, 40 years 6 6; three women). In brain regions with strong susceptibility effects from the metallic braces, T2-prepared functional MRI showed significantly higher SNR (37.8 6 2.4 vs 15.5 6 5.3; P , .001) and contrast-to-noise ratio (0.83 6 0.16 vs 0.29 6 0.10; P , .001), whereas diffusion-prepared DTI showed higher SNR (5.8 6 1.5 vs 3.8 6 0.7; P = .03) than did conventional EPI methods. Apparent diffusion coefficient and fractional anisotropy were consistent with the literature. Geometric distortion was substantially reduced throughout the brain with the proposed methods (significantly higher Jaccard index, 0.95 6 0.12 vs 0.81 6 0.61; P , .001). Conclusion: T2-prepared functional MRI and diffusion-prepared diffusion tensor imaging can acquire functional and diffusion MRI, respectively, in healthy human participants wearing metallic dental braces with less susceptibility artifacts and geometric distortion than with conventional echo-planar imaging.

Original languageEnglish (US)
Pages (from-to)149-157
Number of pages9
JournalRADIOLOGY
Volume294
Issue number1
DOIs
StatePublished - 2020

ASJC Scopus subject areas

  • Radiology Nuclear Medicine and imaging

Fingerprint

Dive into the research topics of 'Whole-brain functional and diffusion tensor MRI in human participants with metallic orthodontic braces'. Together they form a unique fingerprint.

Cite this