WE‐E‐330D‐05: Investigation of Imaging Performance and Acquisition Technique for a New Dual‐Energy Chest Imaging System

N. Shkumat, Jeff Siewerdsen, A. Dhanantwari, D. Williams, S. Richard, M. Daly, N. Paul, D. Moseley, D. Jaffray, J. Yorkston, R. Vanmetter

Research output: Contribution to journalArticle

Abstract

Purpose: A novel, high‐performance, cardiac‐gated dual‐energy (DE) chest system is under development in our lab. This paper investigates the influence of key image acquisition technique parameters (viz., selection of kVp, filtration, and dose) on DE imaging performance. Method and Materials: Experiments were conducted on a DE imaging bench with a custom‐built phantom containing simulated lung nodules of varying contrast. Performance was quantified in terms of nodule contrast‐noise ratio (CNRDE) in DE ‘tissue‐only’ images. Low‐ and high‐kVp were varied from 60–90 kVp and 120–150 kVp, respectively. Differential added filtration in low‐ and high‐kVp projections was analyzed in terms of soft‐tissue CNRDE both theoretically across the entire Periodic Table (Z=1−92) and experimentally for specific material types (Al, Ce, Cu, and Ag). Allocation of dose (defined A=ESDlow/ESDhigh) between low‐ and high‐energy projections was analyzed at various levels of total entrance surface dose, ESD, over a broad range of allocation. Results: The results provide valuable guidance of technique selection for high‐performance DE imaging. Optimal performance was achieved at a technique of [60/130] kVp, increasing soft‐tissue CNRDE by 32% compared to [90/120] kVp. Differential added filtration [0.2 mm Ce / 0.6 mm Ag] increased soft‐tissue CNRDE by 21% compared to the undifferentiated case ([1 mm Al / 1 mm Al]). Dose allocation was found to have significant influence on performance, with CNRDE increasing by more than ∼30% for A<1 compared to higher A>3 (with optima suggested in the range A∼0.3–0.5). Conclusion: Knowledgeable selection of kVp pairs, differential added filtration, and dose allocation provide significant increase in the soft‐tissue CNR of DE images compared to conventional or sub‐optimal techniques. Quantitative theoretical and experimental evaluation demonstrates the importance of optimized acquisition techniques for high‐performance DE imaging and guides the implementation of a novel DE imaging system under development for pre‐clinical imaging trials.

Original languageEnglish (US)
Pages (from-to)2252
Number of pages1
JournalMedical Physics
Volume33
Issue number6
DOIs
StatePublished - 2006
Externally publishedYes

Fingerprint

Thorax
Lung

ASJC Scopus subject areas

  • Biophysics
  • Radiology Nuclear Medicine and imaging

Cite this

WE‐E‐330D‐05 : Investigation of Imaging Performance and Acquisition Technique for a New Dual‐Energy Chest Imaging System. / Shkumat, N.; Siewerdsen, Jeff; Dhanantwari, A.; Williams, D.; Richard, S.; Daly, M.; Paul, N.; Moseley, D.; Jaffray, D.; Yorkston, J.; Vanmetter, R.

In: Medical Physics, Vol. 33, No. 6, 2006, p. 2252.

Research output: Contribution to journalArticle

Shkumat, N, Siewerdsen, J, Dhanantwari, A, Williams, D, Richard, S, Daly, M, Paul, N, Moseley, D, Jaffray, D, Yorkston, J & Vanmetter, R 2006, 'WE‐E‐330D‐05: Investigation of Imaging Performance and Acquisition Technique for a New Dual‐Energy Chest Imaging System', Medical Physics, vol. 33, no. 6, pp. 2252. https://doi.org/10.1118/1.2241795
Shkumat, N. ; Siewerdsen, Jeff ; Dhanantwari, A. ; Williams, D. ; Richard, S. ; Daly, M. ; Paul, N. ; Moseley, D. ; Jaffray, D. ; Yorkston, J. ; Vanmetter, R. / WE‐E‐330D‐05 : Investigation of Imaging Performance and Acquisition Technique for a New Dual‐Energy Chest Imaging System. In: Medical Physics. 2006 ; Vol. 33, No. 6. pp. 2252.
@article{a138f0521acb4fea8c27aa8551a0142d,
title = "WE‐E‐330D‐05: Investigation of Imaging Performance and Acquisition Technique for a New Dual‐Energy Chest Imaging System",
abstract = "Purpose: A novel, high‐performance, cardiac‐gated dual‐energy (DE) chest system is under development in our lab. This paper investigates the influence of key image acquisition technique parameters (viz., selection of kVp, filtration, and dose) on DE imaging performance. Method and Materials: Experiments were conducted on a DE imaging bench with a custom‐built phantom containing simulated lung nodules of varying contrast. Performance was quantified in terms of nodule contrast‐noise ratio (CNRDE) in DE ‘tissue‐only’ images. Low‐ and high‐kVp were varied from 60–90 kVp and 120–150 kVp, respectively. Differential added filtration in low‐ and high‐kVp projections was analyzed in terms of soft‐tissue CNRDE both theoretically across the entire Periodic Table (Z=1−92) and experimentally for specific material types (Al, Ce, Cu, and Ag). Allocation of dose (defined A=ESDlow/ESDhigh) between low‐ and high‐energy projections was analyzed at various levels of total entrance surface dose, ESD, over a broad range of allocation. Results: The results provide valuable guidance of technique selection for high‐performance DE imaging. Optimal performance was achieved at a technique of [60/130] kVp, increasing soft‐tissue CNRDE by 32{\%} compared to [90/120] kVp. Differential added filtration [0.2 mm Ce / 0.6 mm Ag] increased soft‐tissue CNRDE by 21{\%} compared to the undifferentiated case ([1 mm Al / 1 mm Al]). Dose allocation was found to have significant influence on performance, with CNRDE increasing by more than ∼30{\%} for A<1 compared to higher A>3 (with optima suggested in the range A∼0.3–0.5). Conclusion: Knowledgeable selection of kVp pairs, differential added filtration, and dose allocation provide significant increase in the soft‐tissue CNR of DE images compared to conventional or sub‐optimal techniques. Quantitative theoretical and experimental evaluation demonstrates the importance of optimized acquisition techniques for high‐performance DE imaging and guides the implementation of a novel DE imaging system under development for pre‐clinical imaging trials.",
author = "N. Shkumat and Jeff Siewerdsen and A. Dhanantwari and D. Williams and S. Richard and M. Daly and N. Paul and D. Moseley and D. Jaffray and J. Yorkston and R. Vanmetter",
year = "2006",
doi = "10.1118/1.2241795",
language = "English (US)",
volume = "33",
pages = "2252",
journal = "Medical Physics",
issn = "0094-2405",
publisher = "AAPM - American Association of Physicists in Medicine",
number = "6",

}

TY - JOUR

T1 - WE‐E‐330D‐05

T2 - Investigation of Imaging Performance and Acquisition Technique for a New Dual‐Energy Chest Imaging System

AU - Shkumat, N.

AU - Siewerdsen, Jeff

AU - Dhanantwari, A.

AU - Williams, D.

AU - Richard, S.

AU - Daly, M.

AU - Paul, N.

AU - Moseley, D.

AU - Jaffray, D.

AU - Yorkston, J.

AU - Vanmetter, R.

PY - 2006

Y1 - 2006

N2 - Purpose: A novel, high‐performance, cardiac‐gated dual‐energy (DE) chest system is under development in our lab. This paper investigates the influence of key image acquisition technique parameters (viz., selection of kVp, filtration, and dose) on DE imaging performance. Method and Materials: Experiments were conducted on a DE imaging bench with a custom‐built phantom containing simulated lung nodules of varying contrast. Performance was quantified in terms of nodule contrast‐noise ratio (CNRDE) in DE ‘tissue‐only’ images. Low‐ and high‐kVp were varied from 60–90 kVp and 120–150 kVp, respectively. Differential added filtration in low‐ and high‐kVp projections was analyzed in terms of soft‐tissue CNRDE both theoretically across the entire Periodic Table (Z=1−92) and experimentally for specific material types (Al, Ce, Cu, and Ag). Allocation of dose (defined A=ESDlow/ESDhigh) between low‐ and high‐energy projections was analyzed at various levels of total entrance surface dose, ESD, over a broad range of allocation. Results: The results provide valuable guidance of technique selection for high‐performance DE imaging. Optimal performance was achieved at a technique of [60/130] kVp, increasing soft‐tissue CNRDE by 32% compared to [90/120] kVp. Differential added filtration [0.2 mm Ce / 0.6 mm Ag] increased soft‐tissue CNRDE by 21% compared to the undifferentiated case ([1 mm Al / 1 mm Al]). Dose allocation was found to have significant influence on performance, with CNRDE increasing by more than ∼30% for A<1 compared to higher A>3 (with optima suggested in the range A∼0.3–0.5). Conclusion: Knowledgeable selection of kVp pairs, differential added filtration, and dose allocation provide significant increase in the soft‐tissue CNR of DE images compared to conventional or sub‐optimal techniques. Quantitative theoretical and experimental evaluation demonstrates the importance of optimized acquisition techniques for high‐performance DE imaging and guides the implementation of a novel DE imaging system under development for pre‐clinical imaging trials.

AB - Purpose: A novel, high‐performance, cardiac‐gated dual‐energy (DE) chest system is under development in our lab. This paper investigates the influence of key image acquisition technique parameters (viz., selection of kVp, filtration, and dose) on DE imaging performance. Method and Materials: Experiments were conducted on a DE imaging bench with a custom‐built phantom containing simulated lung nodules of varying contrast. Performance was quantified in terms of nodule contrast‐noise ratio (CNRDE) in DE ‘tissue‐only’ images. Low‐ and high‐kVp were varied from 60–90 kVp and 120–150 kVp, respectively. Differential added filtration in low‐ and high‐kVp projections was analyzed in terms of soft‐tissue CNRDE both theoretically across the entire Periodic Table (Z=1−92) and experimentally for specific material types (Al, Ce, Cu, and Ag). Allocation of dose (defined A=ESDlow/ESDhigh) between low‐ and high‐energy projections was analyzed at various levels of total entrance surface dose, ESD, over a broad range of allocation. Results: The results provide valuable guidance of technique selection for high‐performance DE imaging. Optimal performance was achieved at a technique of [60/130] kVp, increasing soft‐tissue CNRDE by 32% compared to [90/120] kVp. Differential added filtration [0.2 mm Ce / 0.6 mm Ag] increased soft‐tissue CNRDE by 21% compared to the undifferentiated case ([1 mm Al / 1 mm Al]). Dose allocation was found to have significant influence on performance, with CNRDE increasing by more than ∼30% for A<1 compared to higher A>3 (with optima suggested in the range A∼0.3–0.5). Conclusion: Knowledgeable selection of kVp pairs, differential added filtration, and dose allocation provide significant increase in the soft‐tissue CNR of DE images compared to conventional or sub‐optimal techniques. Quantitative theoretical and experimental evaluation demonstrates the importance of optimized acquisition techniques for high‐performance DE imaging and guides the implementation of a novel DE imaging system under development for pre‐clinical imaging trials.

UR - http://www.scopus.com/inward/record.url?scp=85024780583&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=85024780583&partnerID=8YFLogxK

U2 - 10.1118/1.2241795

DO - 10.1118/1.2241795

M3 - Article

AN - SCOPUS:85024780583

VL - 33

SP - 2252

JO - Medical Physics

JF - Medical Physics

SN - 0094-2405

IS - 6

ER -