Vibration analysis of vessel wall motion with intra vena caval balloon pumping

A. S. Shah, L. W. Lund, F. R. Walters, P. J. Sawzik, G. D. Reeder, H. S. Borovetz, B. G. Hattler

Research output: Contribution to journalArticle

Abstract

The intravenous membrane oxygenator (IMO) incorporates a centrally positioned balloon surrounded by hollow microporous fibers. Previous studies using this configuration have demonstrated that rhythmic pulsation of the balloon enhances gas exchange, presumably by three dimensional convective mixing. This study sought to characterize vessel wall vibrations imparted by intra vena caval balloon pumping. An in vitro flow loop incorporating a current IMO prototype was used for these measurements. The IMO prototype was inserted in a modeled vena cava on which ultrasonic dimension transducers were mounted on the outer surface. The flow loop was operated at physiologic flow rates. The balloon was activated, and dynamic vessel diameter measurements were recorded as the pumping frequency was varied from 40 to 120 beats per minute (bpm). A Fast Fourier Transform algorithm generated a frequency spectrum at each bpm and for two different balloon configurations; a single balloon versus a tripartite arrangement, the authors' results demonstrate that the mean amplitude of vena caval oscillations varied with bpm, and that this variation followed the trends in oxygen transfer rates. This suggests that the motion of the vessel wall may contribute to convective mixing of blood. In addition, this work demonstrated significant differences in the frequency spectra associated with our two balloon configurations.

Original languageEnglish (US)
JournalASAIO Journal
Volume40
Issue number3
StatePublished - Jul 1994
Externally publishedYes

Fingerprint

Membrane Oxygenators
Venae Cavae
Balloons
Vibration analysis
Vibration
Oxygenators
Fourier Analysis
Transducers
Ultrasonics
Membranes
Gases
Oxygen
Fast Fourier transforms
Blood
Flow rate
Fibers

ASJC Scopus subject areas

  • Biophysics
  • Bioengineering

Cite this

Shah, A. S., Lund, L. W., Walters, F. R., Sawzik, P. J., Reeder, G. D., Borovetz, H. S., & Hattler, B. G. (1994). Vibration analysis of vessel wall motion with intra vena caval balloon pumping. ASAIO Journal, 40(3).

Vibration analysis of vessel wall motion with intra vena caval balloon pumping. / Shah, A. S.; Lund, L. W.; Walters, F. R.; Sawzik, P. J.; Reeder, G. D.; Borovetz, H. S.; Hattler, B. G.

In: ASAIO Journal, Vol. 40, No. 3, 07.1994.

Research output: Contribution to journalArticle

Shah, AS, Lund, LW, Walters, FR, Sawzik, PJ, Reeder, GD, Borovetz, HS & Hattler, BG 1994, 'Vibration analysis of vessel wall motion with intra vena caval balloon pumping', ASAIO Journal, vol. 40, no. 3.
Shah AS, Lund LW, Walters FR, Sawzik PJ, Reeder GD, Borovetz HS et al. Vibration analysis of vessel wall motion with intra vena caval balloon pumping. ASAIO Journal. 1994 Jul;40(3).
Shah, A. S. ; Lund, L. W. ; Walters, F. R. ; Sawzik, P. J. ; Reeder, G. D. ; Borovetz, H. S. ; Hattler, B. G. / Vibration analysis of vessel wall motion with intra vena caval balloon pumping. In: ASAIO Journal. 1994 ; Vol. 40, No. 3.
@article{c11a5b5c2ead414c9d814da7de4224e1,
title = "Vibration analysis of vessel wall motion with intra vena caval balloon pumping",
abstract = "The intravenous membrane oxygenator (IMO) incorporates a centrally positioned balloon surrounded by hollow microporous fibers. Previous studies using this configuration have demonstrated that rhythmic pulsation of the balloon enhances gas exchange, presumably by three dimensional convective mixing. This study sought to characterize vessel wall vibrations imparted by intra vena caval balloon pumping. An in vitro flow loop incorporating a current IMO prototype was used for these measurements. The IMO prototype was inserted in a modeled vena cava on which ultrasonic dimension transducers were mounted on the outer surface. The flow loop was operated at physiologic flow rates. The balloon was activated, and dynamic vessel diameter measurements were recorded as the pumping frequency was varied from 40 to 120 beats per minute (bpm). A Fast Fourier Transform algorithm generated a frequency spectrum at each bpm and for two different balloon configurations; a single balloon versus a tripartite arrangement, the authors' results demonstrate that the mean amplitude of vena caval oscillations varied with bpm, and that this variation followed the trends in oxygen transfer rates. This suggests that the motion of the vessel wall may contribute to convective mixing of blood. In addition, this work demonstrated significant differences in the frequency spectra associated with our two balloon configurations.",
author = "Shah, {A. S.} and Lund, {L. W.} and Walters, {F. R.} and Sawzik, {P. J.} and Reeder, {G. D.} and Borovetz, {H. S.} and Hattler, {B. G.}",
year = "1994",
month = "7",
language = "English (US)",
volume = "40",
journal = "ASAIO Journal",
issn = "1058-2916",
publisher = "Lippincott Williams and Wilkins",
number = "3",

}

TY - JOUR

T1 - Vibration analysis of vessel wall motion with intra vena caval balloon pumping

AU - Shah, A. S.

AU - Lund, L. W.

AU - Walters, F. R.

AU - Sawzik, P. J.

AU - Reeder, G. D.

AU - Borovetz, H. S.

AU - Hattler, B. G.

PY - 1994/7

Y1 - 1994/7

N2 - The intravenous membrane oxygenator (IMO) incorporates a centrally positioned balloon surrounded by hollow microporous fibers. Previous studies using this configuration have demonstrated that rhythmic pulsation of the balloon enhances gas exchange, presumably by three dimensional convective mixing. This study sought to characterize vessel wall vibrations imparted by intra vena caval balloon pumping. An in vitro flow loop incorporating a current IMO prototype was used for these measurements. The IMO prototype was inserted in a modeled vena cava on which ultrasonic dimension transducers were mounted on the outer surface. The flow loop was operated at physiologic flow rates. The balloon was activated, and dynamic vessel diameter measurements were recorded as the pumping frequency was varied from 40 to 120 beats per minute (bpm). A Fast Fourier Transform algorithm generated a frequency spectrum at each bpm and for two different balloon configurations; a single balloon versus a tripartite arrangement, the authors' results demonstrate that the mean amplitude of vena caval oscillations varied with bpm, and that this variation followed the trends in oxygen transfer rates. This suggests that the motion of the vessel wall may contribute to convective mixing of blood. In addition, this work demonstrated significant differences in the frequency spectra associated with our two balloon configurations.

AB - The intravenous membrane oxygenator (IMO) incorporates a centrally positioned balloon surrounded by hollow microporous fibers. Previous studies using this configuration have demonstrated that rhythmic pulsation of the balloon enhances gas exchange, presumably by three dimensional convective mixing. This study sought to characterize vessel wall vibrations imparted by intra vena caval balloon pumping. An in vitro flow loop incorporating a current IMO prototype was used for these measurements. The IMO prototype was inserted in a modeled vena cava on which ultrasonic dimension transducers were mounted on the outer surface. The flow loop was operated at physiologic flow rates. The balloon was activated, and dynamic vessel diameter measurements were recorded as the pumping frequency was varied from 40 to 120 beats per minute (bpm). A Fast Fourier Transform algorithm generated a frequency spectrum at each bpm and for two different balloon configurations; a single balloon versus a tripartite arrangement, the authors' results demonstrate that the mean amplitude of vena caval oscillations varied with bpm, and that this variation followed the trends in oxygen transfer rates. This suggests that the motion of the vessel wall may contribute to convective mixing of blood. In addition, this work demonstrated significant differences in the frequency spectra associated with our two balloon configurations.

UR - http://www.scopus.com/inward/record.url?scp=0028464248&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=0028464248&partnerID=8YFLogxK

M3 - Article

C2 - 8555613

AN - SCOPUS:0028464248

VL - 40

JO - ASAIO Journal

JF - ASAIO Journal

SN - 1058-2916

IS - 3

ER -