AU - Lavender, Steven A.
AU - Trafimow, Jordan H.
AU - Andersson, Gunnar B.J.
PY - 1995/7
Y1 - 1995/7
N2 - Study Design. Repeated measurements were made of lumbar sagittal range of motion by 14 examiners using three different measuroment instruments. Objectives. To determine the reliability of lumber range of motion measurements among examiners, subjects, and instruments, and to datermine whether variance is duo to subject inconsistency, examiner inconsistency, differences between examiners, or differences between instruments. Summary of Background Data. Measurements of lumbar spine range of motion are widely used in research and clinical applications as well as in disability rating systems for patients with low back pain. Methods-Fourteen examiners measured the sagittal range of motion. Using three instruments, 18 healthy subjects were measured twice in a randomized sequence with blinded readings when performing full flexion, and partial flexion to a defined midpoint. None of the examiners routinely used the particular instruments in their practices. Results. The mean test-retest reliability was 4,9°. The intraexaminer reliability did not differ significantly among the examiners. Furthermore, there was no systematic difference resulting from instruments or posture condition. However, there was a statistically significant variance among examiners—i.e., a poor interexarmner reliability. Conclusion. The most likely explanation for these findings is the variability among examiners in locating bony landmarks. The results indicate that range of motion measurements must be interpreted with caution in clinical, research, and disability applications. Test administrator training may improve results, but tills could not be determined from this study.
AB - Study Design. Repeated measurements were made of lumbar sagittal range of motion by 14 examiners using three different measuroment instruments. Objectives. To determine the reliability of lumber range of motion measurements among examiners, subjects, and instruments, and to datermine whether variance is duo to subject inconsistency, examiner inconsistency, differences between examiners, or differences between instruments. Summary of Background Data. Measurements of lumbar spine range of motion are widely used in research and clinical applications as well as in disability rating systems for patients with low back pain. Methods-Fourteen examiners measured the sagittal range of motion. Using three instruments, 18 healthy subjects were measured twice in a randomized sequence with blinded readings when performing full flexion, and partial flexion to a defined midpoint. None of the examiners routinely used the particular instruments in their practices. Results. The mean test-retest reliability was 4,9°. The intraexaminer reliability did not differ significantly among the examiners. Furthermore, there was no systematic difference resulting from instruments or posture condition. However, there was a statistically significant variance among examiners—i.e., a poor interexarmner reliability. Conclusion. The most likely explanation for these findings is the variability among examiners in locating bony landmarks. The results indicate that range of motion measurements must be interpreted with caution in clinical, research, and disability applications. Test administrator training may improve results, but tills could not be determined from this study.
KW - Impairment
KW - Low-back pain
KW - Range of motion
KW - Trunk motion
UR - http://www.scopus.com/inward/record.url?scp=0029062227&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=0029062227&partnerID=8YFLogxK
U2 - 10.1097/00007632-199507000-00008
DO - 10.1097/00007632-199507000-00008
M3 - Article
C2 - 8623068
AN - SCOPUS:0029062227
SN - 0362-2436
VL - 20
SP - 1489
EP - 1493
JO - Spine
JF - Spine
IS - 13
ER -