TY - JOUR
T1 - Usefulness of Noninvasively Measured Pulse Amplitude Changes During the Valsalva Maneuver to Identify Hospitalized Heart Failure Patients at Risk of 30-Day Heart Failure Events (from the PRESSURE-HF Study)
AU - Gilotra, Nisha A.
AU - Wanamaker, Brett L.
AU - Rahim, Hussein
AU - Kunkel, Katherine
AU - Yenokyan, Gayane
AU - Schulman, Steven P.
AU - Tedford, Ryan J.
AU - Russell, Stuart D.
AU - Silber, Harry A.
N1 - Publisher Copyright:
© 2019 Elsevier Inc.
PY - 2020/3/15
Y1 - 2020/3/15
N2 - The pulse amplitude ratio (PAR), the ratio of pulse pressure at the end of the Valsalva maneuver to before the onset, correlates with cardiac filling pressure. We have developed a handheld device that uses finger photoplethysmography to measure PAR and estimate left ventricular end diastolic pressure (LVEDP). Patients hospitalized with heart failure (HF) performed three 10-second trials of a standardized Valsalva maneuver (at 20 mm Hg measured via pressure transducer), while photoplethysmography waveforms were recorded, at admission and discharge. Combined primary outcome was 30-day HF hospitalization, intravenous diuresis, or death. Fifty-two subjects had discharge PAR testing; 12 met the primary outcome. Median PAR on admission was 0.55 (interquartile range: 0.40 to 0.70, n = 48) and on discharge was 0.50 (interquartile range: 0.36 to 0.69). Mean PAR-estimated LVEDP was significantly higher in subjects that had an event (20.2 vs 16.9 mm Hg, p = 0.043). Subjects with PAR-estimated LVEDP >19.5 mm Hg had an event rate hazard ratio of 4.57 (95% confidence interval 1.37, 15.19, p = 0.013) compared with patients with LVEDP 19.5 mm Hg or below, with significantly lower 30-day event-free survival (log-rank p = 0.006). In conclusion, noninvasively estimated LVEDP using the pulse amplitude response to a Valsalva maneuver in patients hospitalized for HF changes with diuresis and identifies patients at high risk for 30-day HF events. Detection of elevated filling pressures before hospital discharge may be useful in guiding HF management to reduce HF events.
AB - The pulse amplitude ratio (PAR), the ratio of pulse pressure at the end of the Valsalva maneuver to before the onset, correlates with cardiac filling pressure. We have developed a handheld device that uses finger photoplethysmography to measure PAR and estimate left ventricular end diastolic pressure (LVEDP). Patients hospitalized with heart failure (HF) performed three 10-second trials of a standardized Valsalva maneuver (at 20 mm Hg measured via pressure transducer), while photoplethysmography waveforms were recorded, at admission and discharge. Combined primary outcome was 30-day HF hospitalization, intravenous diuresis, or death. Fifty-two subjects had discharge PAR testing; 12 met the primary outcome. Median PAR on admission was 0.55 (interquartile range: 0.40 to 0.70, n = 48) and on discharge was 0.50 (interquartile range: 0.36 to 0.69). Mean PAR-estimated LVEDP was significantly higher in subjects that had an event (20.2 vs 16.9 mm Hg, p = 0.043). Subjects with PAR-estimated LVEDP >19.5 mm Hg had an event rate hazard ratio of 4.57 (95% confidence interval 1.37, 15.19, p = 0.013) compared with patients with LVEDP 19.5 mm Hg or below, with significantly lower 30-day event-free survival (log-rank p = 0.006). In conclusion, noninvasively estimated LVEDP using the pulse amplitude response to a Valsalva maneuver in patients hospitalized for HF changes with diuresis and identifies patients at high risk for 30-day HF events. Detection of elevated filling pressures before hospital discharge may be useful in guiding HF management to reduce HF events.
UR - http://www.scopus.com/inward/record.url?scp=85077707899&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=85077707899&partnerID=8YFLogxK
U2 - 10.1016/j.amjcard.2019.12.027
DO - 10.1016/j.amjcard.2019.12.027
M3 - Article
C2 - 31928720
AN - SCOPUS:85077707899
SN - 0002-9149
VL - 125
SP - 916
EP - 923
JO - American Journal of Cardiology
JF - American Journal of Cardiology
IS - 6
ER -