Ultrasound guidance for medical thoracoscopy: A novel approach

Craig P. Hersh, David Feller-Kopman, Momen Wahidi, Robert Garland, Felix Herth, Armin Ernst

Research output: Contribution to journalArticle

Abstract

Background: Commonly, a pneumothorax is induced before medical thoracoscopy to facilitate safe entry into the pleural space. Objective: Evaluate the use of transthoracic ultrasound to locate a safe entry site for trocar placement during medical thoracoscopy without induction of a preprocedure pneumothorax. Method: The study was designed as a prospective cohort study, performed in the setting of a tertiary care hospital with an active interventional pulmonology program. It included 20 consecutive patients referred for medical thoracoscopy. Results: Ultrasound identified entry sites in all 20 patients. All sites were successfully used, despite the presence of adhesions in 3 patients. There were no complications. Conclusions: Ultrasound could safely and reliably identify entry sites for trocar placement during medical thoracoscopy, even in patients with pleural adhesions. The use of ultrasound may replace the practice of pneumothorax induction before medical thoracoscopy.

Original languageEnglish (US)
Pages (from-to)299-301
Number of pages3
JournalRespiration
Volume70
Issue number3
DOIs
StatePublished - 2003
Externally publishedYes

Fingerprint

Thoracoscopy
Pneumothorax
Surgical Instruments
Pulmonary Medicine
Tertiary Healthcare
Tertiary Care Centers
Cohort Studies
Prospective Studies

Keywords

  • Pleural diseases
  • Pleural effusion
  • Thoracoscopy
  • Ultrasonography

ASJC Scopus subject areas

  • Pulmonary and Respiratory Medicine
  • Physiology

Cite this

Hersh, C. P., Feller-Kopman, D., Wahidi, M., Garland, R., Herth, F., & Ernst, A. (2003). Ultrasound guidance for medical thoracoscopy: A novel approach. Respiration, 70(3), 299-301. https://doi.org/10.1159/000072012

Ultrasound guidance for medical thoracoscopy : A novel approach. / Hersh, Craig P.; Feller-Kopman, David; Wahidi, Momen; Garland, Robert; Herth, Felix; Ernst, Armin.

In: Respiration, Vol. 70, No. 3, 2003, p. 299-301.

Research output: Contribution to journalArticle

Hersh, CP, Feller-Kopman, D, Wahidi, M, Garland, R, Herth, F & Ernst, A 2003, 'Ultrasound guidance for medical thoracoscopy: A novel approach', Respiration, vol. 70, no. 3, pp. 299-301. https://doi.org/10.1159/000072012
Hersh, Craig P. ; Feller-Kopman, David ; Wahidi, Momen ; Garland, Robert ; Herth, Felix ; Ernst, Armin. / Ultrasound guidance for medical thoracoscopy : A novel approach. In: Respiration. 2003 ; Vol. 70, No. 3. pp. 299-301.
@article{4d01f271205d4f509d67bec6f5cf83dc,
title = "Ultrasound guidance for medical thoracoscopy: A novel approach",
abstract = "Background: Commonly, a pneumothorax is induced before medical thoracoscopy to facilitate safe entry into the pleural space. Objective: Evaluate the use of transthoracic ultrasound to locate a safe entry site for trocar placement during medical thoracoscopy without induction of a preprocedure pneumothorax. Method: The study was designed as a prospective cohort study, performed in the setting of a tertiary care hospital with an active interventional pulmonology program. It included 20 consecutive patients referred for medical thoracoscopy. Results: Ultrasound identified entry sites in all 20 patients. All sites were successfully used, despite the presence of adhesions in 3 patients. There were no complications. Conclusions: Ultrasound could safely and reliably identify entry sites for trocar placement during medical thoracoscopy, even in patients with pleural adhesions. The use of ultrasound may replace the practice of pneumothorax induction before medical thoracoscopy.",
keywords = "Pleural diseases, Pleural effusion, Thoracoscopy, Ultrasonography",
author = "Hersh, {Craig P.} and David Feller-Kopman and Momen Wahidi and Robert Garland and Felix Herth and Armin Ernst",
year = "2003",
doi = "10.1159/000072012",
language = "English (US)",
volume = "70",
pages = "299--301",
journal = "Respiration; international review of thoracic diseases",
issn = "0025-7931",
publisher = "S. Karger AG",
number = "3",

}

TY - JOUR

T1 - Ultrasound guidance for medical thoracoscopy

T2 - A novel approach

AU - Hersh, Craig P.

AU - Feller-Kopman, David

AU - Wahidi, Momen

AU - Garland, Robert

AU - Herth, Felix

AU - Ernst, Armin

PY - 2003

Y1 - 2003

N2 - Background: Commonly, a pneumothorax is induced before medical thoracoscopy to facilitate safe entry into the pleural space. Objective: Evaluate the use of transthoracic ultrasound to locate a safe entry site for trocar placement during medical thoracoscopy without induction of a preprocedure pneumothorax. Method: The study was designed as a prospective cohort study, performed in the setting of a tertiary care hospital with an active interventional pulmonology program. It included 20 consecutive patients referred for medical thoracoscopy. Results: Ultrasound identified entry sites in all 20 patients. All sites were successfully used, despite the presence of adhesions in 3 patients. There were no complications. Conclusions: Ultrasound could safely and reliably identify entry sites for trocar placement during medical thoracoscopy, even in patients with pleural adhesions. The use of ultrasound may replace the practice of pneumothorax induction before medical thoracoscopy.

AB - Background: Commonly, a pneumothorax is induced before medical thoracoscopy to facilitate safe entry into the pleural space. Objective: Evaluate the use of transthoracic ultrasound to locate a safe entry site for trocar placement during medical thoracoscopy without induction of a preprocedure pneumothorax. Method: The study was designed as a prospective cohort study, performed in the setting of a tertiary care hospital with an active interventional pulmonology program. It included 20 consecutive patients referred for medical thoracoscopy. Results: Ultrasound identified entry sites in all 20 patients. All sites were successfully used, despite the presence of adhesions in 3 patients. There were no complications. Conclusions: Ultrasound could safely and reliably identify entry sites for trocar placement during medical thoracoscopy, even in patients with pleural adhesions. The use of ultrasound may replace the practice of pneumothorax induction before medical thoracoscopy.

KW - Pleural diseases

KW - Pleural effusion

KW - Thoracoscopy

KW - Ultrasonography

UR - http://www.scopus.com/inward/record.url?scp=0042072740&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=0042072740&partnerID=8YFLogxK

U2 - 10.1159/000072012

DO - 10.1159/000072012

M3 - Article

C2 - 12915750

AN - SCOPUS:0042072740

VL - 70

SP - 299

EP - 301

JO - Respiration; international review of thoracic diseases

JF - Respiration; international review of thoracic diseases

SN - 0025-7931

IS - 3

ER -