Ultimate intrinsic signal-to-noise ratio in MRI

Ogan Ocali, Ergin Atalar

Research output: Contribution to journalArticle

Abstract

A method to calculate the ultimate intrinsic signal-to-noise ratio (SNR) in a magnetic resonance experiment for a point inside an arbitrarily shaped object is presented. The ultimate intrinsic SNR is determined by body noise. A solution is obtained by optimizing the electromagnetic field to minimize total power deposition while maintaining a constant right-hand circularly polarized component of the magnetic filed at the point interest. A numerical approximation for the optimal field is found by assuming a superposition of a image number of plane waves. This simulation allowed estimation of the ultimate intrinsic SNR attainable in a human torso model. The performance of six coil configurations was evaluated by comparing the SNR of images obtained by the coils with the ultimate values. In addition, the behaviour of ultimate intrinsic SNR was investigated as a function of main field strength. It was found that the ultimate intrinsic SNR increases better than linearly with the main magnetic filed up to 10 T for our model. It was observed that for field strengths of 4 T or higher, focusing is required to reach the ultimate intrinsic SNR.

Original languageEnglish (US)
Pages (from-to)462-473
Number of pages12
JournalMagnetic Resonance in Medicine
Volume39
Issue number3
DOIs
StatePublished - Mar 1998

Fingerprint

Signal-To-Noise Ratio
Torso
Electromagnetic Fields
Noise
Magnetic Resonance Spectroscopy
Hand

Keywords

  • Focusing
  • RF coil design
  • Skin effect
  • SNR optimization

ASJC Scopus subject areas

  • Radiology Nuclear Medicine and imaging
  • Radiological and Ultrasound Technology

Cite this

Ultimate intrinsic signal-to-noise ratio in MRI. / Ocali, Ogan; Atalar, Ergin.

In: Magnetic Resonance in Medicine, Vol. 39, No. 3, 03.1998, p. 462-473.

Research output: Contribution to journalArticle

Ocali, Ogan ; Atalar, Ergin. / Ultimate intrinsic signal-to-noise ratio in MRI. In: Magnetic Resonance in Medicine. 1998 ; Vol. 39, No. 3. pp. 462-473.
@article{05cd8cf86a8d4d3fa8a8adc8226cad5a,
title = "Ultimate intrinsic signal-to-noise ratio in MRI",
abstract = "A method to calculate the ultimate intrinsic signal-to-noise ratio (SNR) in a magnetic resonance experiment for a point inside an arbitrarily shaped object is presented. The ultimate intrinsic SNR is determined by body noise. A solution is obtained by optimizing the electromagnetic field to minimize total power deposition while maintaining a constant right-hand circularly polarized component of the magnetic filed at the point interest. A numerical approximation for the optimal field is found by assuming a superposition of a image number of plane waves. This simulation allowed estimation of the ultimate intrinsic SNR attainable in a human torso model. The performance of six coil configurations was evaluated by comparing the SNR of images obtained by the coils with the ultimate values. In addition, the behaviour of ultimate intrinsic SNR was investigated as a function of main field strength. It was found that the ultimate intrinsic SNR increases better than linearly with the main magnetic filed up to 10 T for our model. It was observed that for field strengths of 4 T or higher, focusing is required to reach the ultimate intrinsic SNR.",
keywords = "Focusing, RF coil design, Skin effect, SNR optimization",
author = "Ogan Ocali and Ergin Atalar",
year = "1998",
month = "3",
doi = "10.1002/mrm.1910390317",
language = "English (US)",
volume = "39",
pages = "462--473",
journal = "Magnetic Resonance in Medicine",
issn = "0740-3194",
publisher = "John Wiley and Sons Inc.",
number = "3",

}

TY - JOUR

T1 - Ultimate intrinsic signal-to-noise ratio in MRI

AU - Ocali, Ogan

AU - Atalar, Ergin

PY - 1998/3

Y1 - 1998/3

N2 - A method to calculate the ultimate intrinsic signal-to-noise ratio (SNR) in a magnetic resonance experiment for a point inside an arbitrarily shaped object is presented. The ultimate intrinsic SNR is determined by body noise. A solution is obtained by optimizing the electromagnetic field to minimize total power deposition while maintaining a constant right-hand circularly polarized component of the magnetic filed at the point interest. A numerical approximation for the optimal field is found by assuming a superposition of a image number of plane waves. This simulation allowed estimation of the ultimate intrinsic SNR attainable in a human torso model. The performance of six coil configurations was evaluated by comparing the SNR of images obtained by the coils with the ultimate values. In addition, the behaviour of ultimate intrinsic SNR was investigated as a function of main field strength. It was found that the ultimate intrinsic SNR increases better than linearly with the main magnetic filed up to 10 T for our model. It was observed that for field strengths of 4 T or higher, focusing is required to reach the ultimate intrinsic SNR.

AB - A method to calculate the ultimate intrinsic signal-to-noise ratio (SNR) in a magnetic resonance experiment for a point inside an arbitrarily shaped object is presented. The ultimate intrinsic SNR is determined by body noise. A solution is obtained by optimizing the electromagnetic field to minimize total power deposition while maintaining a constant right-hand circularly polarized component of the magnetic filed at the point interest. A numerical approximation for the optimal field is found by assuming a superposition of a image number of plane waves. This simulation allowed estimation of the ultimate intrinsic SNR attainable in a human torso model. The performance of six coil configurations was evaluated by comparing the SNR of images obtained by the coils with the ultimate values. In addition, the behaviour of ultimate intrinsic SNR was investigated as a function of main field strength. It was found that the ultimate intrinsic SNR increases better than linearly with the main magnetic filed up to 10 T for our model. It was observed that for field strengths of 4 T or higher, focusing is required to reach the ultimate intrinsic SNR.

KW - Focusing

KW - RF coil design

KW - Skin effect

KW - SNR optimization

UR - http://www.scopus.com/inward/record.url?scp=0031884051&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=0031884051&partnerID=8YFLogxK

U2 - 10.1002/mrm.1910390317

DO - 10.1002/mrm.1910390317

M3 - Article

C2 - 9498603

AN - SCOPUS:0031884051

VL - 39

SP - 462

EP - 473

JO - Magnetic Resonance in Medicine

JF - Magnetic Resonance in Medicine

SN - 0740-3194

IS - 3

ER -