Treatment of patients with prior exit block using a novel steroid-eluting active fixation lead

G. H. Crossley, D. Reynolds, G. N. Kay, T. B. Ferguson, G. Lamas, J. Messenger, M. Zmijewski, Jeffrey A Brinker

Research output: Contribution to journalArticle

Abstract

An increased interest has developed in active fixation leads for several reasons. Exit block is an uncommon complication that is seen with both active and passive fixation leads. Exit block has not been a significant problem with passive fixation steroid-eluting leads and has been treated with these leads. A new steroid-eluting active fixation lead was examined for its performance in patients in whom exit block had previously occurred. The lead function was evaluated prospectively in 24 patients with a history of exit block (15 ventricular and 9 atrial). The results in patients with atrial exit block are encouraging with an average chronic stimulation threshold of 0.19 msecs at 2.5 volts. Results in the ventricle are less encouraging with 3 occurrences of recurrent exit block in 15 patients: however, the remaining patients had a good mean threshold of 0.21 ± 0.11 msecs at 2.5 volts. There were a remarkable number of non-lead related complications suggesting that this is a substantially different group than routine implantations.

Original languageEnglish (US)
Pages (from-to)2042-2046
Number of pages5
JournalPACE - Pacing and Clinical Electrophysiology
Volume17
Issue number11 II
DOIs
StatePublished - 1994

Fingerprint

Steroids
Therapeutics
Lead

ASJC Scopus subject areas

  • Cardiology and Cardiovascular Medicine

Cite this

Treatment of patients with prior exit block using a novel steroid-eluting active fixation lead. / Crossley, G. H.; Reynolds, D.; Kay, G. N.; Ferguson, T. B.; Lamas, G.; Messenger, J.; Zmijewski, M.; Brinker, Jeffrey A.

In: PACE - Pacing and Clinical Electrophysiology, Vol. 17, No. 11 II, 1994, p. 2042-2046.

Research output: Contribution to journalArticle

Crossley, G. H. ; Reynolds, D. ; Kay, G. N. ; Ferguson, T. B. ; Lamas, G. ; Messenger, J. ; Zmijewski, M. ; Brinker, Jeffrey A. / Treatment of patients with prior exit block using a novel steroid-eluting active fixation lead. In: PACE - Pacing and Clinical Electrophysiology. 1994 ; Vol. 17, No. 11 II. pp. 2042-2046.
@article{c2071dcc30b748bea3345606859f7dd6,
title = "Treatment of patients with prior exit block using a novel steroid-eluting active fixation lead",
abstract = "An increased interest has developed in active fixation leads for several reasons. Exit block is an uncommon complication that is seen with both active and passive fixation leads. Exit block has not been a significant problem with passive fixation steroid-eluting leads and has been treated with these leads. A new steroid-eluting active fixation lead was examined for its performance in patients in whom exit block had previously occurred. The lead function was evaluated prospectively in 24 patients with a history of exit block (15 ventricular and 9 atrial). The results in patients with atrial exit block are encouraging with an average chronic stimulation threshold of 0.19 msecs at 2.5 volts. Results in the ventricle are less encouraging with 3 occurrences of recurrent exit block in 15 patients: however, the remaining patients had a good mean threshold of 0.21 ± 0.11 msecs at 2.5 volts. There were a remarkable number of non-lead related complications suggesting that this is a substantially different group than routine implantations.",
author = "Crossley, {G. H.} and D. Reynolds and Kay, {G. N.} and Ferguson, {T. B.} and G. Lamas and J. Messenger and M. Zmijewski and Brinker, {Jeffrey A}",
year = "1994",
doi = "10.1111/j.1540-8159.1994.tb03797.x",
language = "English (US)",
volume = "17",
pages = "2042--2046",
journal = "PACE - Pacing and Clinical Electrophysiology",
issn = "0147-8389",
publisher = "Wiley-Blackwell",
number = "11 II",

}

TY - JOUR

T1 - Treatment of patients with prior exit block using a novel steroid-eluting active fixation lead

AU - Crossley, G. H.

AU - Reynolds, D.

AU - Kay, G. N.

AU - Ferguson, T. B.

AU - Lamas, G.

AU - Messenger, J.

AU - Zmijewski, M.

AU - Brinker, Jeffrey A

PY - 1994

Y1 - 1994

N2 - An increased interest has developed in active fixation leads for several reasons. Exit block is an uncommon complication that is seen with both active and passive fixation leads. Exit block has not been a significant problem with passive fixation steroid-eluting leads and has been treated with these leads. A new steroid-eluting active fixation lead was examined for its performance in patients in whom exit block had previously occurred. The lead function was evaluated prospectively in 24 patients with a history of exit block (15 ventricular and 9 atrial). The results in patients with atrial exit block are encouraging with an average chronic stimulation threshold of 0.19 msecs at 2.5 volts. Results in the ventricle are less encouraging with 3 occurrences of recurrent exit block in 15 patients: however, the remaining patients had a good mean threshold of 0.21 ± 0.11 msecs at 2.5 volts. There were a remarkable number of non-lead related complications suggesting that this is a substantially different group than routine implantations.

AB - An increased interest has developed in active fixation leads for several reasons. Exit block is an uncommon complication that is seen with both active and passive fixation leads. Exit block has not been a significant problem with passive fixation steroid-eluting leads and has been treated with these leads. A new steroid-eluting active fixation lead was examined for its performance in patients in whom exit block had previously occurred. The lead function was evaluated prospectively in 24 patients with a history of exit block (15 ventricular and 9 atrial). The results in patients with atrial exit block are encouraging with an average chronic stimulation threshold of 0.19 msecs at 2.5 volts. Results in the ventricle are less encouraging with 3 occurrences of recurrent exit block in 15 patients: however, the remaining patients had a good mean threshold of 0.21 ± 0.11 msecs at 2.5 volts. There were a remarkable number of non-lead related complications suggesting that this is a substantially different group than routine implantations.

UR - http://www.scopus.com/inward/record.url?scp=0028034018&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=0028034018&partnerID=8YFLogxK

U2 - 10.1111/j.1540-8159.1994.tb03797.x

DO - 10.1111/j.1540-8159.1994.tb03797.x

M3 - Article

VL - 17

SP - 2042

EP - 2046

JO - PACE - Pacing and Clinical Electrophysiology

JF - PACE - Pacing and Clinical Electrophysiology

SN - 0147-8389

IS - 11 II

ER -