Tracking the position and rotational orientation of a catheter using a transmit array system

Haydar Celik, Davut I. Mahcicek, Oytunk Senel, Graham A. Wright, Ergin Atalar

Research output: Contribution to journalArticle

Abstract

A new method for detecting the rotational orientation and tracking the position of an inductively coupled radio frequency (ICRF) coil using a transmit array system is proposed. The method employs a conventional body birdcage coil, but the quadrature hybrid is eliminated so that the two excitation channels can be used separately. The transmit array system provides RF excitations such that the body birdcage coil creates linearly polarized and changing RF pulses instead of a conventional rotational forward-polarized excitation. The receive coils and their operations are not modified. Inductively coupled RF coils are constructed on catheters for detecting rotational orientation and for tracking purposes. Signals from the anatomy and from tissue close to the ICRF coil are different due to the new RF excitation scheme: the ICRF coil can be separated from the anatomy in real time, and after doing so, a color-coded image is reconstructed. More importantly, this novel method enables a real-time calculation of the absolute rotational orientation of an ICRF coil constructed on a catheter.

Original languageEnglish (US)
Article number6461415
Pages (from-to)809-817
Number of pages9
JournalIEEE Transactions on Medical Imaging
Volume32
Issue number4
DOIs
StatePublished - 2013
Externally publishedYes

Fingerprint

Catheters
Radio
Anatomy
Color
Tissue

Keywords

  • Catheter tracking
  • inductively coupled radio-frequency (ICRF) coil
  • interventional MRI
  • rotational orientation
  • transmit array

ASJC Scopus subject areas

  • Electrical and Electronic Engineering
  • Computer Science Applications
  • Radiological and Ultrasound Technology
  • Software

Cite this

Tracking the position and rotational orientation of a catheter using a transmit array system. / Celik, Haydar; Mahcicek, Davut I.; Senel, Oytunk; Wright, Graham A.; Atalar, Ergin.

In: IEEE Transactions on Medical Imaging, Vol. 32, No. 4, 6461415, 2013, p. 809-817.

Research output: Contribution to journalArticle

Celik, Haydar ; Mahcicek, Davut I. ; Senel, Oytunk ; Wright, Graham A. ; Atalar, Ergin. / Tracking the position and rotational orientation of a catheter using a transmit array system. In: IEEE Transactions on Medical Imaging. 2013 ; Vol. 32, No. 4. pp. 809-817.
@article{31a4b664dbde4934b111294f8bdbf20a,
title = "Tracking the position and rotational orientation of a catheter using a transmit array system",
abstract = "A new method for detecting the rotational orientation and tracking the position of an inductively coupled radio frequency (ICRF) coil using a transmit array system is proposed. The method employs a conventional body birdcage coil, but the quadrature hybrid is eliminated so that the two excitation channels can be used separately. The transmit array system provides RF excitations such that the body birdcage coil creates linearly polarized and changing RF pulses instead of a conventional rotational forward-polarized excitation. The receive coils and their operations are not modified. Inductively coupled RF coils are constructed on catheters for detecting rotational orientation and for tracking purposes. Signals from the anatomy and from tissue close to the ICRF coil are different due to the new RF excitation scheme: the ICRF coil can be separated from the anatomy in real time, and after doing so, a color-coded image is reconstructed. More importantly, this novel method enables a real-time calculation of the absolute rotational orientation of an ICRF coil constructed on a catheter.",
keywords = "Catheter tracking, inductively coupled radio-frequency (ICRF) coil, interventional MRI, rotational orientation, transmit array",
author = "Haydar Celik and Mahcicek, {Davut I.} and Oytunk Senel and Wright, {Graham A.} and Ergin Atalar",
year = "2013",
doi = "10.1109/TMI.2013.2247047",
language = "English (US)",
volume = "32",
pages = "809--817",
journal = "IEEE Transactions on Medical Imaging",
issn = "0278-0062",
publisher = "Institute of Electrical and Electronics Engineers Inc.",
number = "4",

}

TY - JOUR

T1 - Tracking the position and rotational orientation of a catheter using a transmit array system

AU - Celik, Haydar

AU - Mahcicek, Davut I.

AU - Senel, Oytunk

AU - Wright, Graham A.

AU - Atalar, Ergin

PY - 2013

Y1 - 2013

N2 - A new method for detecting the rotational orientation and tracking the position of an inductively coupled radio frequency (ICRF) coil using a transmit array system is proposed. The method employs a conventional body birdcage coil, but the quadrature hybrid is eliminated so that the two excitation channels can be used separately. The transmit array system provides RF excitations such that the body birdcage coil creates linearly polarized and changing RF pulses instead of a conventional rotational forward-polarized excitation. The receive coils and their operations are not modified. Inductively coupled RF coils are constructed on catheters for detecting rotational orientation and for tracking purposes. Signals from the anatomy and from tissue close to the ICRF coil are different due to the new RF excitation scheme: the ICRF coil can be separated from the anatomy in real time, and after doing so, a color-coded image is reconstructed. More importantly, this novel method enables a real-time calculation of the absolute rotational orientation of an ICRF coil constructed on a catheter.

AB - A new method for detecting the rotational orientation and tracking the position of an inductively coupled radio frequency (ICRF) coil using a transmit array system is proposed. The method employs a conventional body birdcage coil, but the quadrature hybrid is eliminated so that the two excitation channels can be used separately. The transmit array system provides RF excitations such that the body birdcage coil creates linearly polarized and changing RF pulses instead of a conventional rotational forward-polarized excitation. The receive coils and their operations are not modified. Inductively coupled RF coils are constructed on catheters for detecting rotational orientation and for tracking purposes. Signals from the anatomy and from tissue close to the ICRF coil are different due to the new RF excitation scheme: the ICRF coil can be separated from the anatomy in real time, and after doing so, a color-coded image is reconstructed. More importantly, this novel method enables a real-time calculation of the absolute rotational orientation of an ICRF coil constructed on a catheter.

KW - Catheter tracking

KW - inductively coupled radio-frequency (ICRF) coil

KW - interventional MRI

KW - rotational orientation

KW - transmit array

UR - http://www.scopus.com/inward/record.url?scp=84875990405&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=84875990405&partnerID=8YFLogxK

U2 - 10.1109/TMI.2013.2247047

DO - 10.1109/TMI.2013.2247047

M3 - Article

C2 - 23412592

AN - SCOPUS:84875990405

VL - 32

SP - 809

EP - 817

JO - IEEE Transactions on Medical Imaging

JF - IEEE Transactions on Medical Imaging

SN - 0278-0062

IS - 4

M1 - 6461415

ER -