Tissue-integrated prostheses in the rehabilitation of auricular defects: Results with percutaneous mastoid implants

J. K. Niparko, A. W. Langman, D. S. Cutler, W. R. Carroll

Research output: Contribution to journalArticlepeer-review

20 Scopus citations

Abstract

Functional and cosmetic rehabilitation of the severely atretic auricle poses a formidable challenge. Conventional autologous grafts for auricular reconstruction may produce inconsistent results, and revision of failed grafts is often unsatisfactory. Osseointegrated implant systems to retain auricular prostheses provide an alternative approach in rehabilitating patients with severe auricular defects. Fourteen patients were implanted with 30 osseointegrating implants for rehabilitating major auricular defects and were followed for 1 to 3.5 years, yielding 143 implant observations. Symptomatic skin reactions to the percutaneous implant were noted in 3.5 percent of the observations. Implant extrusion did not occur. This evaluation of tissue-integrated prosthetic systems suggests this approach to be an extremely reliable alternative for selected patients with major auricular defects. The technique of implanting the retention unit is readily adapted to atresia repair.

Original languageEnglish (US)
Pages (from-to)343-348
Number of pages6
JournalAmerican Journal of Otology
Volume14
Issue number4
StatePublished - 1993

ASJC Scopus subject areas

  • Otorhinolaryngology

Fingerprint

Dive into the research topics of 'Tissue-integrated prostheses in the rehabilitation of auricular defects: Results with percutaneous mastoid implants'. Together they form a unique fingerprint.

Cite this