Time domain removal of irrelevant magnetization in chemical exchange saturation transfer Z-spectra

Nirbhay N. Yadav, Kannie W Y Chan, Craig Jones, Michael T Mcmahon, Peter C Van Zijl

Research output: Contribution to journalArticle

Abstract

Purpose To evaluate the possibility of processing Z-spectra using time domain analysis. Methods An inverse Fourier transform (IFT) is applied on Z-spectra, thus transforming the chemical exchange saturation transfer (CEST) data into the time domain. Here, large interfering signals from solvent and semisolid magnetization transfer can be fit and filtered out. The method is demonstrated on a range of phantoms (creatine, a para-CEST agent, and hen egg white) and also in vivo on a mouse brain. Results Using time domain analysis, signal components in Z-spectra could be fit very well, thus enabling irreverent or nuisance components to be removed. The method worked equally well for samples in a solution or a gel where the large contribution from conventional magnetization transfer contrast (MTC) was easily separated out. Results from egg white and mouse brain in vivo data showed that the large water resonance could easily be removed thus allowing the remaining signal to be analyzed without interference from direct water saturation. Conclusions This method successfully filtered out the large nuisance signals from bulk water and MTC in Z-spectra in a large variety of phantom types and also in vivo. It is expected to be a potentially powerful tool for CEST studies without needing asymmetry analysis.

Original languageEnglish (US)
Pages (from-to)547-555
Number of pages9
JournalMagnetic Resonance in Medicine
Volume70
Issue number2
DOIs
StatePublished - Aug 2013

Fingerprint

Egg White
Water
Creatine
Brain
Fourier Analysis
Gels

Keywords

  • CEST
  • discrete inverse Fourier transform
  • magnetization transfer
  • time domain analysis

ASJC Scopus subject areas

  • Radiology Nuclear Medicine and imaging

Cite this

Time domain removal of irrelevant magnetization in chemical exchange saturation transfer Z-spectra. / Yadav, Nirbhay N.; Chan, Kannie W Y; Jones, Craig; Mcmahon, Michael T; Van Zijl, Peter C.

In: Magnetic Resonance in Medicine, Vol. 70, No. 2, 08.2013, p. 547-555.

Research output: Contribution to journalArticle

@article{f34b46d7f3034202b920e1fbe20e63a0,
title = "Time domain removal of irrelevant magnetization in chemical exchange saturation transfer Z-spectra",
abstract = "Purpose To evaluate the possibility of processing Z-spectra using time domain analysis. Methods An inverse Fourier transform (IFT) is applied on Z-spectra, thus transforming the chemical exchange saturation transfer (CEST) data into the time domain. Here, large interfering signals from solvent and semisolid magnetization transfer can be fit and filtered out. The method is demonstrated on a range of phantoms (creatine, a para-CEST agent, and hen egg white) and also in vivo on a mouse brain. Results Using time domain analysis, signal components in Z-spectra could be fit very well, thus enabling irreverent or nuisance components to be removed. The method worked equally well for samples in a solution or a gel where the large contribution from conventional magnetization transfer contrast (MTC) was easily separated out. Results from egg white and mouse brain in vivo data showed that the large water resonance could easily be removed thus allowing the remaining signal to be analyzed without interference from direct water saturation. Conclusions This method successfully filtered out the large nuisance signals from bulk water and MTC in Z-spectra in a large variety of phantom types and also in vivo. It is expected to be a potentially powerful tool for CEST studies without needing asymmetry analysis.",
keywords = "CEST, discrete inverse Fourier transform, magnetization transfer, time domain analysis",
author = "Yadav, {Nirbhay N.} and Chan, {Kannie W Y} and Craig Jones and Mcmahon, {Michael T} and {Van Zijl}, {Peter C}",
year = "2013",
month = "8",
doi = "10.1002/mrm.24812",
language = "English (US)",
volume = "70",
pages = "547--555",
journal = "Magnetic Resonance in Medicine",
issn = "0740-3194",
publisher = "John Wiley and Sons Inc.",
number = "2",

}

TY - JOUR

T1 - Time domain removal of irrelevant magnetization in chemical exchange saturation transfer Z-spectra

AU - Yadav, Nirbhay N.

AU - Chan, Kannie W Y

AU - Jones, Craig

AU - Mcmahon, Michael T

AU - Van Zijl, Peter C

PY - 2013/8

Y1 - 2013/8

N2 - Purpose To evaluate the possibility of processing Z-spectra using time domain analysis. Methods An inverse Fourier transform (IFT) is applied on Z-spectra, thus transforming the chemical exchange saturation transfer (CEST) data into the time domain. Here, large interfering signals from solvent and semisolid magnetization transfer can be fit and filtered out. The method is demonstrated on a range of phantoms (creatine, a para-CEST agent, and hen egg white) and also in vivo on a mouse brain. Results Using time domain analysis, signal components in Z-spectra could be fit very well, thus enabling irreverent or nuisance components to be removed. The method worked equally well for samples in a solution or a gel where the large contribution from conventional magnetization transfer contrast (MTC) was easily separated out. Results from egg white and mouse brain in vivo data showed that the large water resonance could easily be removed thus allowing the remaining signal to be analyzed without interference from direct water saturation. Conclusions This method successfully filtered out the large nuisance signals from bulk water and MTC in Z-spectra in a large variety of phantom types and also in vivo. It is expected to be a potentially powerful tool for CEST studies without needing asymmetry analysis.

AB - Purpose To evaluate the possibility of processing Z-spectra using time domain analysis. Methods An inverse Fourier transform (IFT) is applied on Z-spectra, thus transforming the chemical exchange saturation transfer (CEST) data into the time domain. Here, large interfering signals from solvent and semisolid magnetization transfer can be fit and filtered out. The method is demonstrated on a range of phantoms (creatine, a para-CEST agent, and hen egg white) and also in vivo on a mouse brain. Results Using time domain analysis, signal components in Z-spectra could be fit very well, thus enabling irreverent or nuisance components to be removed. The method worked equally well for samples in a solution or a gel where the large contribution from conventional magnetization transfer contrast (MTC) was easily separated out. Results from egg white and mouse brain in vivo data showed that the large water resonance could easily be removed thus allowing the remaining signal to be analyzed without interference from direct water saturation. Conclusions This method successfully filtered out the large nuisance signals from bulk water and MTC in Z-spectra in a large variety of phantom types and also in vivo. It is expected to be a potentially powerful tool for CEST studies without needing asymmetry analysis.

KW - CEST

KW - discrete inverse Fourier transform

KW - magnetization transfer

KW - time domain analysis

UR - http://www.scopus.com/inward/record.url?scp=84881130730&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=84881130730&partnerID=8YFLogxK

U2 - 10.1002/mrm.24812

DO - 10.1002/mrm.24812

M3 - Article

C2 - 23798323

AN - SCOPUS:84881130730

VL - 70

SP - 547

EP - 555

JO - Magnetic Resonance in Medicine

JF - Magnetic Resonance in Medicine

SN - 0740-3194

IS - 2

ER -