Background: Preoperative quantitative assessment of glenoid bone loss, selection of the glenoid component, and definition of its desired location can be challenging. Placement of the glenoid component in the desired location at the time of surgery is difficult, especially with severe glenoid pathological conditions. Methods: Forty-six patients were randomly assigned to three-dimensional computed tomographic preoperative templating with either standard instrumentation or with patient-specific instrumentation and were compared with a nonrandomized group of seventeen patients with two-dimensional imaging and standard instrumentation used as historical controls. All patients had postoperative three-dimensional computed tomographic metal artifact reduction imaging to measure and to compare implant position with the preoperative plan. Results: Using three-dimensional imaging and templating with or without patient-specific instrumentation, there was a significant improvement achieving the desired implant position within 5° of inclination or 10° of version when compared with two-dimensional imaging and standard instrumentation. Conclusion: Three-dimensional assessment of glenoid anatomy and implant templating and the use of these images at the time of surgery improve the surgeon's ability to place the glenoid implant in the desired location. Level of Evidence: Therapeutic Level III. See Instructions for Authors for a complete description of levels of evidence.

Original languageEnglish (US)
Pages (from-to)651-658
Number of pages8
JournalJournal of Bone and Joint Surgery - American Volume
Volume97
Issue number8
DOIs
StatePublished - Apr 15 2015
Externally publishedYes

Fingerprint

Three-Dimensional Imaging
Artifacts
Anatomy
Metals
Bone and Bones

ASJC Scopus subject areas

  • Surgery
  • Orthopedics and Sports Medicine

Cite this

Iannotti, J. P., Weiner, S., Rodriguez, E., Subhas, N., Patterson, T. E., Jun, B. J., & Ricchetti, E. T. (2015). Three-dimensional imaging and templating improve glenoid implant positioning. Journal of Bone and Joint Surgery - American Volume, 97(8), 651-658. https://doi.org/10.2106/JBJS.N.00493

Three-dimensional imaging and templating improve glenoid implant positioning. / Iannotti, Joseph P.; Weiner, Scott; Rodriguez, Eric; Subhas, Naveen; Patterson, Thomas E.; Jun, Bong Jae; Ricchetti, Eric T.

In: Journal of Bone and Joint Surgery - American Volume, Vol. 97, No. 8, 15.04.2015, p. 651-658.

Research output: Contribution to journalArticle

Iannotti, JP, Weiner, S, Rodriguez, E, Subhas, N, Patterson, TE, Jun, BJ & Ricchetti, ET 2015, 'Three-dimensional imaging and templating improve glenoid implant positioning', Journal of Bone and Joint Surgery - American Volume, vol. 97, no. 8, pp. 651-658. https://doi.org/10.2106/JBJS.N.00493
Iannotti, Joseph P. ; Weiner, Scott ; Rodriguez, Eric ; Subhas, Naveen ; Patterson, Thomas E. ; Jun, Bong Jae ; Ricchetti, Eric T. / Three-dimensional imaging and templating improve glenoid implant positioning. In: Journal of Bone and Joint Surgery - American Volume. 2015 ; Vol. 97, No. 8. pp. 651-658.
@article{113b136ebc6c45d2a097b180db4eed42,
title = "Three-dimensional imaging and templating improve glenoid implant positioning",
abstract = "Background: Preoperative quantitative assessment of glenoid bone loss, selection of the glenoid component, and definition of its desired location can be challenging. Placement of the glenoid component in the desired location at the time of surgery is difficult, especially with severe glenoid pathological conditions. Methods: Forty-six patients were randomly assigned to three-dimensional computed tomographic preoperative templating with either standard instrumentation or with patient-specific instrumentation and were compared with a nonrandomized group of seventeen patients with two-dimensional imaging and standard instrumentation used as historical controls. All patients had postoperative three-dimensional computed tomographic metal artifact reduction imaging to measure and to compare implant position with the preoperative plan. Results: Using three-dimensional imaging and templating with or without patient-specific instrumentation, there was a significant improvement achieving the desired implant position within 5° of inclination or 10° of version when compared with two-dimensional imaging and standard instrumentation. Conclusion: Three-dimensional assessment of glenoid anatomy and implant templating and the use of these images at the time of surgery improve the surgeon's ability to place the glenoid implant in the desired location. Level of Evidence: Therapeutic Level III. See Instructions for Authors for a complete description of levels of evidence.",
author = "Iannotti, {Joseph P.} and Scott Weiner and Eric Rodriguez and Naveen Subhas and Patterson, {Thomas E.} and Jun, {Bong Jae} and Ricchetti, {Eric T.}",
year = "2015",
month = "4",
day = "15",
doi = "10.2106/JBJS.N.00493",
language = "English (US)",
volume = "97",
pages = "651--658",
journal = "Journal of Bone and Joint Surgery - Series A",
issn = "0021-9355",
publisher = "Journal of Bone and Joint Surgery Inc.",
number = "8",

}

TY - JOUR

T1 - Three-dimensional imaging and templating improve glenoid implant positioning

AU - Iannotti, Joseph P.

AU - Weiner, Scott

AU - Rodriguez, Eric

AU - Subhas, Naveen

AU - Patterson, Thomas E.

AU - Jun, Bong Jae

AU - Ricchetti, Eric T.

PY - 2015/4/15

Y1 - 2015/4/15

N2 - Background: Preoperative quantitative assessment of glenoid bone loss, selection of the glenoid component, and definition of its desired location can be challenging. Placement of the glenoid component in the desired location at the time of surgery is difficult, especially with severe glenoid pathological conditions. Methods: Forty-six patients were randomly assigned to three-dimensional computed tomographic preoperative templating with either standard instrumentation or with patient-specific instrumentation and were compared with a nonrandomized group of seventeen patients with two-dimensional imaging and standard instrumentation used as historical controls. All patients had postoperative three-dimensional computed tomographic metal artifact reduction imaging to measure and to compare implant position with the preoperative plan. Results: Using three-dimensional imaging and templating with or without patient-specific instrumentation, there was a significant improvement achieving the desired implant position within 5° of inclination or 10° of version when compared with two-dimensional imaging and standard instrumentation. Conclusion: Three-dimensional assessment of glenoid anatomy and implant templating and the use of these images at the time of surgery improve the surgeon's ability to place the glenoid implant in the desired location. Level of Evidence: Therapeutic Level III. See Instructions for Authors for a complete description of levels of evidence.

AB - Background: Preoperative quantitative assessment of glenoid bone loss, selection of the glenoid component, and definition of its desired location can be challenging. Placement of the glenoid component in the desired location at the time of surgery is difficult, especially with severe glenoid pathological conditions. Methods: Forty-six patients were randomly assigned to three-dimensional computed tomographic preoperative templating with either standard instrumentation or with patient-specific instrumentation and were compared with a nonrandomized group of seventeen patients with two-dimensional imaging and standard instrumentation used as historical controls. All patients had postoperative three-dimensional computed tomographic metal artifact reduction imaging to measure and to compare implant position with the preoperative plan. Results: Using three-dimensional imaging and templating with or without patient-specific instrumentation, there was a significant improvement achieving the desired implant position within 5° of inclination or 10° of version when compared with two-dimensional imaging and standard instrumentation. Conclusion: Three-dimensional assessment of glenoid anatomy and implant templating and the use of these images at the time of surgery improve the surgeon's ability to place the glenoid implant in the desired location. Level of Evidence: Therapeutic Level III. See Instructions for Authors for a complete description of levels of evidence.

UR - http://www.scopus.com/inward/record.url?scp=84928194479&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=84928194479&partnerID=8YFLogxK

U2 - 10.2106/JBJS.N.00493

DO - 10.2106/JBJS.N.00493

M3 - Article

C2 - 25878309

AN - SCOPUS:84928194479

VL - 97

SP - 651

EP - 658

JO - Journal of Bone and Joint Surgery - Series A

JF - Journal of Bone and Joint Surgery - Series A

SN - 0021-9355

IS - 8

ER -