T1 - Three-dimensional fast acquisition with sonographically based volume computer-aided analysis for imaging of the fetal heart at 18 to 22 week's gestation
AU - Cohen, Leeber
AU - Mangers, Kristie
AU - Grobman, William A.
AU - Gotteiner, Nina
AU - Julien, Svena
AU - Dungan, Jeffrey
AU - Fonseca, Linda
AU - Platt, Lawrence D.
PY - 2010/5/1
Y1 - 2010/5/1
N2 - Objective. The purpose of this study was to determine how frequently cardiac images derived from 3-dimensional (3D) volume sets, acquired by fast acquisition and evaluated with sonographically based volume computer-aided analysis (sonoVCAD), were satisfactory for prenatal screening at 18 to 22 weeks' gestation. Methods. A prospective study of 100 women with singleton pregnancies was undertaken. Three fast acquisition 3D volume sets were obtained from each patient. Four reviewers independently evaluated the 4-chamber and 5 extracted VCAD views. Factors contributing to unsatisfactory screening were also evaluated. Results. The frequency with which adequate views for cardiac screening could be obtained varied widely; some single views, such as that of the stomach, were well seen frequently, whereas others, such as the ductal arch, were well seen significantly less frequently (P < .05). A satisfactory screening examination, defined as a visualized 4-chamber, left ventricular outflow tract, right ventricular outflow tract, and axial stomach view, was obtained for 43% to 65% of patients (dependent on reviewer). Logistic regression revealed that obesity (odds ratio, 3.0; 95% confidence interval, 1.7-5.0) and a fetus with the spine toward the maternal abdomen (odds ratio, 1.7; 95% confidence interval, 1.1-2.5) were independently associated with an unsatisfactory screening examination Conclusions. Three-dimensional fast acquisition volumes evaluated with sonoVCAD did not allow a satisfactory fetal cardiac screening examination to be obtained a high percentage of the time in a general obstetric population during the second trimester. Certain patient factors, such as body habitus and fetal position, are associated with unsatisfactory 3D imaging.
AB - Objective. The purpose of this study was to determine how frequently cardiac images derived from 3-dimensional (3D) volume sets, acquired by fast acquisition and evaluated with sonographically based volume computer-aided analysis (sonoVCAD), were satisfactory for prenatal screening at 18 to 22 weeks' gestation. Methods. A prospective study of 100 women with singleton pregnancies was undertaken. Three fast acquisition 3D volume sets were obtained from each patient. Four reviewers independently evaluated the 4-chamber and 5 extracted VCAD views. Factors contributing to unsatisfactory screening were also evaluated. Results. The frequency with which adequate views for cardiac screening could be obtained varied widely; some single views, such as that of the stomach, were well seen frequently, whereas others, such as the ductal arch, were well seen significantly less frequently (P < .05). A satisfactory screening examination, defined as a visualized 4-chamber, left ventricular outflow tract, right ventricular outflow tract, and axial stomach view, was obtained for 43% to 65% of patients (dependent on reviewer). Logistic regression revealed that obesity (odds ratio, 3.0; 95% confidence interval, 1.7-5.0) and a fetus with the spine toward the maternal abdomen (odds ratio, 1.7; 95% confidence interval, 1.1-2.5) were independently associated with an unsatisfactory screening examination Conclusions. Three-dimensional fast acquisition volumes evaluated with sonoVCAD did not allow a satisfactory fetal cardiac screening examination to be obtained a high percentage of the time in a general obstetric population during the second trimester. Certain patient factors, such as body habitus and fetal position, are associated with unsatisfactory 3D imaging.
KW - 3-dimensional screening
KW - Computer-aided analysis
KW - Fetal heart
UR - http://www.scopus.com/inward/record.url?scp=77951970594&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=77951970594&partnerID=8YFLogxK
U2 - 10.7863/jum.2010.29.5.751
DO - 10.7863/jum.2010.29.5.751
M3 - Article
C2 - 20427787
AN - SCOPUS:77951970594
SN - 0278-4297
VL - 29
SP - 751
EP - 757
JO - Journal of Ultrasound in Medicine
JF - Journal of Ultrasound in Medicine
IS - 5
ER -