The aortic bodice: A life-saving maneuver

Juan Sanchez, J. A. Elefteriades, G. L. Hammond

Research output: Contribution to journalArticle

Abstract

A technique is described for control of bleeding from the site of aortic cannulation after removal of the cannula. The technique employs a Dacron graft wrapped under some tension around the site.

Original languageEnglish (US)
Pages (from-to)252-253
Number of pages2
JournalAnnals of Thoracic Surgery
Volume58
Issue number1
StatePublished - 1994
Externally publishedYes

Fingerprint

Polyethylene Terephthalates
Catheterization
Hemorrhage
Transplants
Cannula

ASJC Scopus subject areas

  • Cardiology and Cardiovascular Medicine
  • Surgery

Cite this

Sanchez, J., Elefteriades, J. A., & Hammond, G. L. (1994). The aortic bodice: A life-saving maneuver. Annals of Thoracic Surgery, 58(1), 252-253.

The aortic bodice : A life-saving maneuver. / Sanchez, Juan; Elefteriades, J. A.; Hammond, G. L.

In: Annals of Thoracic Surgery, Vol. 58, No. 1, 1994, p. 252-253.

Research output: Contribution to journalArticle

Sanchez, J, Elefteriades, JA & Hammond, GL 1994, 'The aortic bodice: A life-saving maneuver', Annals of Thoracic Surgery, vol. 58, no. 1, pp. 252-253.
Sanchez J, Elefteriades JA, Hammond GL. The aortic bodice: A life-saving maneuver. Annals of Thoracic Surgery. 1994;58(1):252-253.
Sanchez, Juan ; Elefteriades, J. A. ; Hammond, G. L. / The aortic bodice : A life-saving maneuver. In: Annals of Thoracic Surgery. 1994 ; Vol. 58, No. 1. pp. 252-253.
@article{7cc503910fe94370a06e4d1875bde9f6,
title = "The aortic bodice: A life-saving maneuver",
abstract = "A technique is described for control of bleeding from the site of aortic cannulation after removal of the cannula. The technique employs a Dacron graft wrapped under some tension around the site.",
author = "Juan Sanchez and Elefteriades, {J. A.} and Hammond, {G. L.}",
year = "1994",
language = "English (US)",
volume = "58",
pages = "252--253",
journal = "Annals of Thoracic Surgery",
issn = "0003-4975",
publisher = "Elsevier USA",
number = "1",

}

TY - JOUR

T1 - The aortic bodice

T2 - A life-saving maneuver

AU - Sanchez, Juan

AU - Elefteriades, J. A.

AU - Hammond, G. L.

PY - 1994

Y1 - 1994

N2 - A technique is described for control of bleeding from the site of aortic cannulation after removal of the cannula. The technique employs a Dacron graft wrapped under some tension around the site.

AB - A technique is described for control of bleeding from the site of aortic cannulation after removal of the cannula. The technique employs a Dacron graft wrapped under some tension around the site.

UR - http://www.scopus.com/inward/record.url?scp=0027964903&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=0027964903&partnerID=8YFLogxK

M3 - Article

C2 - 8037542

AN - SCOPUS:0027964903

VL - 58

SP - 252

EP - 253

JO - Annals of Thoracic Surgery

JF - Annals of Thoracic Surgery

SN - 0003-4975

IS - 1

ER -