TY - JOUR
T1 - Test-retest reliability of subjective visual vertical measurements with lateral head tilt in virtual reality goggles
AU - Wang, Chia Han
AU - Winnick, Ariel A.
AU - Ko, Yu Hung
AU - Wang, Zheyu
AU - Chang, Tzu Pu
N1 - Publisher Copyright:
© 2020 Tzu Chi Medical Journal | Published by Wolters Kluwer-Medknow.
PY - 2021/7/1
Y1 - 2021/7/1
N2 - Objective: The objective is to investigate the test-retest reliability of subjective visual vertical (SVV) in the upright position and with lateral head tilts through a computerized SVV measuring system using virtual reality (VR) goggles. Materials and Methods: Thirty healthy controls underwent SVV test in upright position, with the head tilted to the right 30°, and with the head tilted to the left 30°. Subjects wore SVV VR goggles, which contained a gyroscope for monitoring the angle of head tilt. Each subject completed 10 adjustments in each head position. The mean value of SVV deviations and SVV imprecision (the intra-individual variability of SVV deviations from the 10 adjustments) were recorded and compared across different head positions. The participants then repeated the same SVV protocol at least 1 week later. The test-retest reliability of SVV deviation and SVV imprecision were analyzed. Results: The SVV deviation (mean ± standard deviation) was 0.22° ± 1.56° in upright position,-9.64° ± 5.91° in right head tilt, and 7.20° ± 6.36° in left head tilt. The test-retest reliability of SVV deviation was excellent in upright position (intra-class correlation coefficient [ICC] = 0.77, P < 0.001), right head tilt (ICC = 0.83, P < 0.001) and left head tilt (ICC = 0.84, P < 0.001). The SVV values from the 10 adjustments made during right and left head tilts were less precise than when measured at upright (P < 0.001). The test-retest reliability of SVV imprecision was poor at upright (ICC = 0.21, P = 0.26) but fair-to-good in right head tilt (ICC = 0.72, P < 0.001) and left head tilt (ICC = 0.44, P = 0.04). Conclusion: The test-retest reliability of SVV deviation during lateral head tilts via VR goggles is excellent, which supports further research into the diagnostic value of head-tilt SVV in various vestibular disorders. In addition, the degree of SVV imprecision during head tilt has fair-to-good test-retest reliability, which suggests SVV imprecision may have clinical applicability.
AB - Objective: The objective is to investigate the test-retest reliability of subjective visual vertical (SVV) in the upright position and with lateral head tilts through a computerized SVV measuring system using virtual reality (VR) goggles. Materials and Methods: Thirty healthy controls underwent SVV test in upright position, with the head tilted to the right 30°, and with the head tilted to the left 30°. Subjects wore SVV VR goggles, which contained a gyroscope for monitoring the angle of head tilt. Each subject completed 10 adjustments in each head position. The mean value of SVV deviations and SVV imprecision (the intra-individual variability of SVV deviations from the 10 adjustments) were recorded and compared across different head positions. The participants then repeated the same SVV protocol at least 1 week later. The test-retest reliability of SVV deviation and SVV imprecision were analyzed. Results: The SVV deviation (mean ± standard deviation) was 0.22° ± 1.56° in upright position,-9.64° ± 5.91° in right head tilt, and 7.20° ± 6.36° in left head tilt. The test-retest reliability of SVV deviation was excellent in upright position (intra-class correlation coefficient [ICC] = 0.77, P < 0.001), right head tilt (ICC = 0.83, P < 0.001) and left head tilt (ICC = 0.84, P < 0.001). The SVV values from the 10 adjustments made during right and left head tilts were less precise than when measured at upright (P < 0.001). The test-retest reliability of SVV imprecision was poor at upright (ICC = 0.21, P = 0.26) but fair-to-good in right head tilt (ICC = 0.72, P < 0.001) and left head tilt (ICC = 0.44, P = 0.04). Conclusion: The test-retest reliability of SVV deviation during lateral head tilts via VR goggles is excellent, which supports further research into the diagnostic value of head-tilt SVV in various vestibular disorders. In addition, the degree of SVV imprecision during head tilt has fair-to-good test-retest reliability, which suggests SVV imprecision may have clinical applicability.
KW - Reliability
KW - Subjective visual vertical
KW - Vestibular perception
KW - Vestibular test
UR - http://www.scopus.com/inward/record.url?scp=85109704534&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=85109704534&partnerID=8YFLogxK
U2 - 10.4103/tcmj.tcmj_207_20
DO - 10.4103/tcmj.tcmj_207_20
M3 - Article
C2 - 34386369
AN - SCOPUS:85109704534
SN - 1016-3190
VL - 33
SP - 294
EP - 300
JO - Tzu Chi Medical Journal
JF - Tzu Chi Medical Journal
IS - 3
ER -