Temperature measurements during laser skin welding

Nathaniel M. Fried, Bernard Choi, Ashley J. Welch, Joseph T. Walsh

Research output: Chapter in Book/Report/Conference proceedingChapter

Abstract

A thermal camera was used to measure surface temperatures during laser skin welding to provide feedback for optimization of the laser parameters. Two-cm-long, full-thickness incisions were made in guinea pig skin. India ink was used as an absorber. Continuous-wave, 1.06-μm, Nd:YAG laser radiation was scanned over the incisions, producing a pulse duration of approximately 100 ms. Cooling durations between scans of 1.6, 4.0, and 8.0 s were studied with total operation times of 3, 5, and 10 min, respectively. A laser spot diameter of 5 mm was used with the power constant at 10 W. Thermal images were obtained at 30 frames per second with a thermal camera detecting 3-5 μm radiation. Surface temperatures were recorded at 0, 1, and 6 mm from the center line of the incision. Cooling durations between scans of 1.6 s and 4.0 s in vitro resulted in temperatures at the weld site remaining above approximately 65 °C for prolonged periods of time. Cooling durations between scans as long as 8.0 s were sufficient both in vitro and in vivo to prevent a significant rise in baseline temperatures at the weld site over time.

Original languageEnglish (US)
Title of host publicationProceedings of SPIE - The International Society for Optical Engineering
PublisherSociety of Photo-Optical Instrumentation Engineers
Pages120-127
Number of pages8
Volume3590
StatePublished - 1999
EventProceedings of the 1999 Lasers in Surgery: Advanced Characterization, Therapeutics, and Systems IX - San Jose, CA, USA
Duration: Jan 23 1999Jan 24 1999

Other

OtherProceedings of the 1999 Lasers in Surgery: Advanced Characterization, Therapeutics, and Systems IX
CitySan Jose, CA, USA
Period1/23/991/24/99

Fingerprint

welding
Temperature measurement
temperature measurement
Skin
Welding
Lasers
Cooling
lasers
Welds
Cameras
cooling
Temperature
surface temperature
Laser radiation
cameras
Ink
guinea pigs
inks
Feedback
India

ASJC Scopus subject areas

  • Electrical and Electronic Engineering
  • Condensed Matter Physics

Cite this

Fried, N. M., Choi, B., Welch, A. J., & Walsh, J. T. (1999). Temperature measurements during laser skin welding. In Proceedings of SPIE - The International Society for Optical Engineering (Vol. 3590, pp. 120-127). Society of Photo-Optical Instrumentation Engineers.

Temperature measurements during laser skin welding. / Fried, Nathaniel M.; Choi, Bernard; Welch, Ashley J.; Walsh, Joseph T.

Proceedings of SPIE - The International Society for Optical Engineering. Vol. 3590 Society of Photo-Optical Instrumentation Engineers, 1999. p. 120-127.

Research output: Chapter in Book/Report/Conference proceedingChapter

Fried, NM, Choi, B, Welch, AJ & Walsh, JT 1999, Temperature measurements during laser skin welding. in Proceedings of SPIE - The International Society for Optical Engineering. vol. 3590, Society of Photo-Optical Instrumentation Engineers, pp. 120-127, Proceedings of the 1999 Lasers in Surgery: Advanced Characterization, Therapeutics, and Systems IX, San Jose, CA, USA, 1/23/99.
Fried NM, Choi B, Welch AJ, Walsh JT. Temperature measurements during laser skin welding. In Proceedings of SPIE - The International Society for Optical Engineering. Vol. 3590. Society of Photo-Optical Instrumentation Engineers. 1999. p. 120-127
Fried, Nathaniel M. ; Choi, Bernard ; Welch, Ashley J. ; Walsh, Joseph T. / Temperature measurements during laser skin welding. Proceedings of SPIE - The International Society for Optical Engineering. Vol. 3590 Society of Photo-Optical Instrumentation Engineers, 1999. pp. 120-127
@inbook{942b6f8ef9db47cfb4bd8418c2eea69d,
title = "Temperature measurements during laser skin welding",
abstract = "A thermal camera was used to measure surface temperatures during laser skin welding to provide feedback for optimization of the laser parameters. Two-cm-long, full-thickness incisions were made in guinea pig skin. India ink was used as an absorber. Continuous-wave, 1.06-μm, Nd:YAG laser radiation was scanned over the incisions, producing a pulse duration of approximately 100 ms. Cooling durations between scans of 1.6, 4.0, and 8.0 s were studied with total operation times of 3, 5, and 10 min, respectively. A laser spot diameter of 5 mm was used with the power constant at 10 W. Thermal images were obtained at 30 frames per second with a thermal camera detecting 3-5 μm radiation. Surface temperatures were recorded at 0, 1, and 6 mm from the center line of the incision. Cooling durations between scans of 1.6 s and 4.0 s in vitro resulted in temperatures at the weld site remaining above approximately 65 °C for prolonged periods of time. Cooling durations between scans as long as 8.0 s were sufficient both in vitro and in vivo to prevent a significant rise in baseline temperatures at the weld site over time.",
author = "Fried, {Nathaniel M.} and Bernard Choi and Welch, {Ashley J.} and Walsh, {Joseph T.}",
year = "1999",
language = "English (US)",
volume = "3590",
pages = "120--127",
booktitle = "Proceedings of SPIE - The International Society for Optical Engineering",
publisher = "Society of Photo-Optical Instrumentation Engineers",

}

TY - CHAP

T1 - Temperature measurements during laser skin welding

AU - Fried, Nathaniel M.

AU - Choi, Bernard

AU - Welch, Ashley J.

AU - Walsh, Joseph T.

PY - 1999

Y1 - 1999

N2 - A thermal camera was used to measure surface temperatures during laser skin welding to provide feedback for optimization of the laser parameters. Two-cm-long, full-thickness incisions were made in guinea pig skin. India ink was used as an absorber. Continuous-wave, 1.06-μm, Nd:YAG laser radiation was scanned over the incisions, producing a pulse duration of approximately 100 ms. Cooling durations between scans of 1.6, 4.0, and 8.0 s were studied with total operation times of 3, 5, and 10 min, respectively. A laser spot diameter of 5 mm was used with the power constant at 10 W. Thermal images were obtained at 30 frames per second with a thermal camera detecting 3-5 μm radiation. Surface temperatures were recorded at 0, 1, and 6 mm from the center line of the incision. Cooling durations between scans of 1.6 s and 4.0 s in vitro resulted in temperatures at the weld site remaining above approximately 65 °C for prolonged periods of time. Cooling durations between scans as long as 8.0 s were sufficient both in vitro and in vivo to prevent a significant rise in baseline temperatures at the weld site over time.

AB - A thermal camera was used to measure surface temperatures during laser skin welding to provide feedback for optimization of the laser parameters. Two-cm-long, full-thickness incisions were made in guinea pig skin. India ink was used as an absorber. Continuous-wave, 1.06-μm, Nd:YAG laser radiation was scanned over the incisions, producing a pulse duration of approximately 100 ms. Cooling durations between scans of 1.6, 4.0, and 8.0 s were studied with total operation times of 3, 5, and 10 min, respectively. A laser spot diameter of 5 mm was used with the power constant at 10 W. Thermal images were obtained at 30 frames per second with a thermal camera detecting 3-5 μm radiation. Surface temperatures were recorded at 0, 1, and 6 mm from the center line of the incision. Cooling durations between scans of 1.6 s and 4.0 s in vitro resulted in temperatures at the weld site remaining above approximately 65 °C for prolonged periods of time. Cooling durations between scans as long as 8.0 s were sufficient both in vitro and in vivo to prevent a significant rise in baseline temperatures at the weld site over time.

UR - http://www.scopus.com/inward/record.url?scp=0032640967&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=0032640967&partnerID=8YFLogxK

M3 - Chapter

AN - SCOPUS:0032640967

VL - 3590

SP - 120

EP - 127

BT - Proceedings of SPIE - The International Society for Optical Engineering

PB - Society of Photo-Optical Instrumentation Engineers

ER -