TY - JOUR
T1 - Swept source optical coherence tomography measurement of the iris-trabecular contact (ITC) index
T2 - A new parameter for angle closure
AU - Ho, Sue Wei
AU - Baskaran, Mani
AU - Zheng, Ce
AU - Tun, Tin A.
AU - Perera, Shamira A.
AU - Narayanaswamy, Arun K.
AU - Friedman, David S.
AU - Aung, Tin
N1 - Funding Information:
Financial Support The study was supported by a Translational Clinical Research Program grant, Biomedical Research Council (BMRC), Singapore S.-W.Ho.M.Baskaran.C.Zheng.T.A.Tun.S.A.Perera. A. K. Narayanaswamy.T. Aung Singapore Eye Research Institute and Singapore National Eye Centre, Singapore, Singapore
PY - 2013/4
Y1 - 2013/4
N2 - Purpose: To evaluate the inter- and intra-observer agreement of measurement of the iris-trabecular contact (ITC) index, a measure of the degree of angle closure, using swept source optical coherence tomography (SSOCT, CASIA SS-1000, Tomey Corporation, Nagoya, Japan). Methods: One randomly selected eye of 60 subjects was imaged under dark room conditions. The SSOCT 3-dimensional angle scan simultaneously obtains 128 radial scans of the anterior chamber for the entire circumference of the angle. Post-imaging analysis estimated the ITC index using in-built software. For intra-observer agreement for image grading, one examiner performed the grading twice in a masked fashion and random order after a 1-week interval. A second examiner graded images to assess inter-observer agreement for image grading. For intra-observer agreement for image acquisition, a single operator imaged patients twice. For inter-observer agreement for image acquisition, a single observer graded two sets of images acquired by two different operators on the same patient. Bland-Altman plots and 95 % limits of agreement (LOA) were reported. Results: Study subjects were predominantly Chinese (54/60, 90 %) and female (42/60, 70 %), with a mean age of 65.5 years. The median ITC index for eyes with open angles (31/60) and closed angles was 20 % (95 % confidence interval [CI] - 13.6, 27.8) and 49 % (95%CI - 35.5, 69.2) respectively. The mean difference (95 % LOA) for intra-observer agreement for image grading and image acquisition were -0.8 % (-8.2, 6.5) and 0.6 % (-10.9, 9.7); corresponding inter- observer agreement were 0.1 % (-10, 10.1) and -0.3 % (-11.1, 10.5) respectively. Conclusions: The inter- and intra-observer agreement of the ITC index, as a measure of extent of angle closure using SSOCT, was good.
AB - Purpose: To evaluate the inter- and intra-observer agreement of measurement of the iris-trabecular contact (ITC) index, a measure of the degree of angle closure, using swept source optical coherence tomography (SSOCT, CASIA SS-1000, Tomey Corporation, Nagoya, Japan). Methods: One randomly selected eye of 60 subjects was imaged under dark room conditions. The SSOCT 3-dimensional angle scan simultaneously obtains 128 radial scans of the anterior chamber for the entire circumference of the angle. Post-imaging analysis estimated the ITC index using in-built software. For intra-observer agreement for image grading, one examiner performed the grading twice in a masked fashion and random order after a 1-week interval. A second examiner graded images to assess inter-observer agreement for image grading. For intra-observer agreement for image acquisition, a single operator imaged patients twice. For inter-observer agreement for image acquisition, a single observer graded two sets of images acquired by two different operators on the same patient. Bland-Altman plots and 95 % limits of agreement (LOA) were reported. Results: Study subjects were predominantly Chinese (54/60, 90 %) and female (42/60, 70 %), with a mean age of 65.5 years. The median ITC index for eyes with open angles (31/60) and closed angles was 20 % (95 % confidence interval [CI] - 13.6, 27.8) and 49 % (95%CI - 35.5, 69.2) respectively. The mean difference (95 % LOA) for intra-observer agreement for image grading and image acquisition were -0.8 % (-8.2, 6.5) and 0.6 % (-10.9, 9.7); corresponding inter- observer agreement were 0.1 % (-10, 10.1) and -0.3 % (-11.1, 10.5) respectively. Conclusions: The inter- and intra-observer agreement of the ITC index, as a measure of extent of angle closure using SSOCT, was good.
KW - Agreement
KW - Angle closure glaucoma
KW - Gonioscopy
KW - Iris
KW - Swept source optical coherence tomography
UR - http://www.scopus.com/inward/record.url?scp=84876685902&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=84876685902&partnerID=8YFLogxK
U2 - 10.1007/s00417-012-2158-6
DO - 10.1007/s00417-012-2158-6
M3 - Article
C2 - 23001586
AN - SCOPUS:84876685902
SN - 0721-832X
VL - 251
SP - 1205
EP - 1211
JO - Albrecht von Graefes Archiv für Klinische und Experimentelle Ophthalmologie
JF - Albrecht von Graefes Archiv für Klinische und Experimentelle Ophthalmologie
IS - 4
ER -