Soft-tissue imaging with C-arm cone-beam CT using statistical reconstruction

Adam S. Wang, Joseph Webster Stayman, Yoshito Otake, Gerhard Kleinszig, Sebastian Vogt, Gary L Gallia, A Jay Khanna, Jeff Siewerdsen

Research output: Contribution to journalArticle

Abstract

The potential for statistical image reconstruction methods such as penalized-likelihood (PL) to improve C-arm cone-beam CT (CBCT) soft-tissue visualization for intraoperative imaging over conventional filtered backprojection (FBP) is assessed in this work by making a fair comparison in relation to soft-tissue performance. A prototype mobile C-arm was used to scan anthropomorphic head and abdomen phantoms as well as a cadaveric torso at doses substantially lower than typical values in diagnostic CT, and the effects of dose reduction via tube current reduction and sparse sampling were also compared. Matched spatial resolution between PL and FBP was determined by the edge spread function of low-contrast (∼40-80 HU) spheres in the phantoms, which were representative of soft-tissue imaging tasks. PL using the non-quadratic Huber penalty was found to substantially reduce noise relative to FBP, especially at lower spatial resolution where PL provides a contrast-to-noise ratio increase up to 1.4-2.2× over FBP at 50% dose reduction across all objects. Comparison of sampling strategies indicates that soft-tissue imaging benefits from fully sampled acquisitions at dose above ∼1.7 mGy and benefits from 50% sparsity at dose below ∼1.0 mGy. Therefore, an appropriate sampling strategy along with the improved low-contrast visualization offered by statistical reconstruction demonstrates the potential for extending intraoperative C-arm CBCT to applications in soft-tissue interventions in neurosurgery as well as thoracic and abdominal surgeries by overcoming conventional tradeoffs in noise, spatial resolution, and dose.

Original languageEnglish (US)
Pages (from-to)1005-1026
Number of pages22
JournalPhysics in Medicine and Biology
Volume59
Issue number4
DOIs
StatePublished - Feb 21 2014

Fingerprint

Arm
Noise
Torso
Cone-Beam Computed Tomography
Computer-Assisted Image Processing
Neurosurgery
Abdomen
Thoracic Surgery
Head

Keywords

  • cone-beam CT
  • image reconstruction
  • image-guided surgery
  • mobile C-arm
  • soft-tissue imaging
  • sparse sampling
  • statistical reconstruction

ASJC Scopus subject areas

  • Radiology Nuclear Medicine and imaging
  • Radiological and Ultrasound Technology

Cite this

Soft-tissue imaging with C-arm cone-beam CT using statistical reconstruction. / Wang, Adam S.; Stayman, Joseph Webster; Otake, Yoshito; Kleinszig, Gerhard; Vogt, Sebastian; Gallia, Gary L; Khanna, A Jay; Siewerdsen, Jeff.

In: Physics in Medicine and Biology, Vol. 59, No. 4, 21.02.2014, p. 1005-1026.

Research output: Contribution to journalArticle

@article{aa4b6b14f7b34c1f9bbeb29e0608fc17,
title = "Soft-tissue imaging with C-arm cone-beam CT using statistical reconstruction",
abstract = "The potential for statistical image reconstruction methods such as penalized-likelihood (PL) to improve C-arm cone-beam CT (CBCT) soft-tissue visualization for intraoperative imaging over conventional filtered backprojection (FBP) is assessed in this work by making a fair comparison in relation to soft-tissue performance. A prototype mobile C-arm was used to scan anthropomorphic head and abdomen phantoms as well as a cadaveric torso at doses substantially lower than typical values in diagnostic CT, and the effects of dose reduction via tube current reduction and sparse sampling were also compared. Matched spatial resolution between PL and FBP was determined by the edge spread function of low-contrast (∼40-80 HU) spheres in the phantoms, which were representative of soft-tissue imaging tasks. PL using the non-quadratic Huber penalty was found to substantially reduce noise relative to FBP, especially at lower spatial resolution where PL provides a contrast-to-noise ratio increase up to 1.4-2.2× over FBP at 50{\%} dose reduction across all objects. Comparison of sampling strategies indicates that soft-tissue imaging benefits from fully sampled acquisitions at dose above ∼1.7 mGy and benefits from 50{\%} sparsity at dose below ∼1.0 mGy. Therefore, an appropriate sampling strategy along with the improved low-contrast visualization offered by statistical reconstruction demonstrates the potential for extending intraoperative C-arm CBCT to applications in soft-tissue interventions in neurosurgery as well as thoracic and abdominal surgeries by overcoming conventional tradeoffs in noise, spatial resolution, and dose.",
keywords = "cone-beam CT, image reconstruction, image-guided surgery, mobile C-arm, soft-tissue imaging, sparse sampling, statistical reconstruction",
author = "Wang, {Adam S.} and Stayman, {Joseph Webster} and Yoshito Otake and Gerhard Kleinszig and Sebastian Vogt and Gallia, {Gary L} and Khanna, {A Jay} and Jeff Siewerdsen",
year = "2014",
month = "2",
day = "21",
doi = "10.1088/0031-9155/59/4/1005",
language = "English (US)",
volume = "59",
pages = "1005--1026",
journal = "Physics in Medicine and Biology",
issn = "0031-9155",
publisher = "IOP Publishing Ltd.",
number = "4",

}

TY - JOUR

T1 - Soft-tissue imaging with C-arm cone-beam CT using statistical reconstruction

AU - Wang, Adam S.

AU - Stayman, Joseph Webster

AU - Otake, Yoshito

AU - Kleinszig, Gerhard

AU - Vogt, Sebastian

AU - Gallia, Gary L

AU - Khanna, A Jay

AU - Siewerdsen, Jeff

PY - 2014/2/21

Y1 - 2014/2/21

N2 - The potential for statistical image reconstruction methods such as penalized-likelihood (PL) to improve C-arm cone-beam CT (CBCT) soft-tissue visualization for intraoperative imaging over conventional filtered backprojection (FBP) is assessed in this work by making a fair comparison in relation to soft-tissue performance. A prototype mobile C-arm was used to scan anthropomorphic head and abdomen phantoms as well as a cadaveric torso at doses substantially lower than typical values in diagnostic CT, and the effects of dose reduction via tube current reduction and sparse sampling were also compared. Matched spatial resolution between PL and FBP was determined by the edge spread function of low-contrast (∼40-80 HU) spheres in the phantoms, which were representative of soft-tissue imaging tasks. PL using the non-quadratic Huber penalty was found to substantially reduce noise relative to FBP, especially at lower spatial resolution where PL provides a contrast-to-noise ratio increase up to 1.4-2.2× over FBP at 50% dose reduction across all objects. Comparison of sampling strategies indicates that soft-tissue imaging benefits from fully sampled acquisitions at dose above ∼1.7 mGy and benefits from 50% sparsity at dose below ∼1.0 mGy. Therefore, an appropriate sampling strategy along with the improved low-contrast visualization offered by statistical reconstruction demonstrates the potential for extending intraoperative C-arm CBCT to applications in soft-tissue interventions in neurosurgery as well as thoracic and abdominal surgeries by overcoming conventional tradeoffs in noise, spatial resolution, and dose.

AB - The potential for statistical image reconstruction methods such as penalized-likelihood (PL) to improve C-arm cone-beam CT (CBCT) soft-tissue visualization for intraoperative imaging over conventional filtered backprojection (FBP) is assessed in this work by making a fair comparison in relation to soft-tissue performance. A prototype mobile C-arm was used to scan anthropomorphic head and abdomen phantoms as well as a cadaveric torso at doses substantially lower than typical values in diagnostic CT, and the effects of dose reduction via tube current reduction and sparse sampling were also compared. Matched spatial resolution between PL and FBP was determined by the edge spread function of low-contrast (∼40-80 HU) spheres in the phantoms, which were representative of soft-tissue imaging tasks. PL using the non-quadratic Huber penalty was found to substantially reduce noise relative to FBP, especially at lower spatial resolution where PL provides a contrast-to-noise ratio increase up to 1.4-2.2× over FBP at 50% dose reduction across all objects. Comparison of sampling strategies indicates that soft-tissue imaging benefits from fully sampled acquisitions at dose above ∼1.7 mGy and benefits from 50% sparsity at dose below ∼1.0 mGy. Therefore, an appropriate sampling strategy along with the improved low-contrast visualization offered by statistical reconstruction demonstrates the potential for extending intraoperative C-arm CBCT to applications in soft-tissue interventions in neurosurgery as well as thoracic and abdominal surgeries by overcoming conventional tradeoffs in noise, spatial resolution, and dose.

KW - cone-beam CT

KW - image reconstruction

KW - image-guided surgery

KW - mobile C-arm

KW - soft-tissue imaging

KW - sparse sampling

KW - statistical reconstruction

UR - http://www.scopus.com/inward/record.url?scp=84893866716&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=84893866716&partnerID=8YFLogxK

U2 - 10.1088/0031-9155/59/4/1005

DO - 10.1088/0031-9155/59/4/1005

M3 - Article

C2 - 24504126

AN - SCOPUS:84893866716

VL - 59

SP - 1005

EP - 1026

JO - Physics in Medicine and Biology

JF - Physics in Medicine and Biology

SN - 0031-9155

IS - 4

ER -