Sleep and daytime sleepiness of patients with left ventricular assist devices

A longitudinal pilot study

Jesus Casida, Jean E. Davis, Robert J. Brewer, Cheryl Smith, Hossein Yarandi

Research output: Contribution to journalArticle

Abstract

Context: No empirical longitudinal data on sleep and daytime sleepiness patterns in patients with an implantable left ventricular assist device (LVAD) exist. Objective: (1) To describe the sleep patterns (sleep onset latency, sleep efficiency, sleep fragmentation index, total sleep time, and wake after sleep onset), sleep quality, and daytime sleepiness variables and (2) to determine the change in the pattern of these variables before and up to 6 months after LVAD implantation. Design: A longitudinal descriptive repeated-measures design was used. Patients wore wrist actigraphs (AW64 Actiwatch), which objectively measured sleep, for 3 consecutive days and nights before LVAD implant and at the first and second week and first, third, and sixth month after implantation. During these periods, patients also completed questionnaires on sleep quality and daytime sleepiness. Patients: Twelve of 15 patients completed the 6-month data. Data were analyzed by using descriptive statistics and repeated-measures analysis of variance. Results: We found long sleep onset latencies and low sleep efficiency across time periods. High sleep fragmentation index was noted at baseline and 1 week after LVAD. Short total sleep times, long wake-after-sleep-onset durations, and poor sleep quality were evident at baseline and persisted up to 6 months after LVAD implantation. Low alertness level, a manifestation of sleepiness, was common during late morning to early evening hours. However, only sleep efficiency and wake after sleep onset showed significant changes in pattern (P < .05). Conclusion: Sleep disturbance and daytime sleepiness may be prevalent before and up to 6 months after LVAD implantation, warranting further investigation.

Original languageEnglish (US)
Pages (from-to)131-136
Number of pages6
JournalProgress in Transplantation
Volume21
Issue number2
DOIs
StatePublished - Jun 1 2011
Externally publishedYes

Fingerprint

Heart-Assist Devices
Longitudinal Studies
Sleep
Sleep Deprivation

ASJC Scopus subject areas

  • Transplantation

Cite this

Sleep and daytime sleepiness of patients with left ventricular assist devices : A longitudinal pilot study. / Casida, Jesus; Davis, Jean E.; Brewer, Robert J.; Smith, Cheryl; Yarandi, Hossein.

In: Progress in Transplantation, Vol. 21, No. 2, 01.06.2011, p. 131-136.

Research output: Contribution to journalArticle

Casida, Jesus ; Davis, Jean E. ; Brewer, Robert J. ; Smith, Cheryl ; Yarandi, Hossein. / Sleep and daytime sleepiness of patients with left ventricular assist devices : A longitudinal pilot study. In: Progress in Transplantation. 2011 ; Vol. 21, No. 2. pp. 131-136.
@article{95b9af9db3784334978d9ee00fd7c3f1,
title = "Sleep and daytime sleepiness of patients with left ventricular assist devices: A longitudinal pilot study",
abstract = "Context: No empirical longitudinal data on sleep and daytime sleepiness patterns in patients with an implantable left ventricular assist device (LVAD) exist. Objective: (1) To describe the sleep patterns (sleep onset latency, sleep efficiency, sleep fragmentation index, total sleep time, and wake after sleep onset), sleep quality, and daytime sleepiness variables and (2) to determine the change in the pattern of these variables before and up to 6 months after LVAD implantation. Design: A longitudinal descriptive repeated-measures design was used. Patients wore wrist actigraphs (AW64 Actiwatch), which objectively measured sleep, for 3 consecutive days and nights before LVAD implant and at the first and second week and first, third, and sixth month after implantation. During these periods, patients also completed questionnaires on sleep quality and daytime sleepiness. Patients: Twelve of 15 patients completed the 6-month data. Data were analyzed by using descriptive statistics and repeated-measures analysis of variance. Results: We found long sleep onset latencies and low sleep efficiency across time periods. High sleep fragmentation index was noted at baseline and 1 week after LVAD. Short total sleep times, long wake-after-sleep-onset durations, and poor sleep quality were evident at baseline and persisted up to 6 months after LVAD implantation. Low alertness level, a manifestation of sleepiness, was common during late morning to early evening hours. However, only sleep efficiency and wake after sleep onset showed significant changes in pattern (P < .05). Conclusion: Sleep disturbance and daytime sleepiness may be prevalent before and up to 6 months after LVAD implantation, warranting further investigation.",
author = "Jesus Casida and Davis, {Jean E.} and Brewer, {Robert J.} and Cheryl Smith and Hossein Yarandi",
year = "2011",
month = "6",
day = "1",
doi = "10.7182/prtr.21.2.cp5874v2l28g62x6",
language = "English (US)",
volume = "21",
pages = "131--136",
journal = "Progress in Transplantation",
issn = "1526-9248",
publisher = "InnoVision Communications",
number = "2",

}

TY - JOUR

T1 - Sleep and daytime sleepiness of patients with left ventricular assist devices

T2 - A longitudinal pilot study

AU - Casida, Jesus

AU - Davis, Jean E.

AU - Brewer, Robert J.

AU - Smith, Cheryl

AU - Yarandi, Hossein

PY - 2011/6/1

Y1 - 2011/6/1

N2 - Context: No empirical longitudinal data on sleep and daytime sleepiness patterns in patients with an implantable left ventricular assist device (LVAD) exist. Objective: (1) To describe the sleep patterns (sleep onset latency, sleep efficiency, sleep fragmentation index, total sleep time, and wake after sleep onset), sleep quality, and daytime sleepiness variables and (2) to determine the change in the pattern of these variables before and up to 6 months after LVAD implantation. Design: A longitudinal descriptive repeated-measures design was used. Patients wore wrist actigraphs (AW64 Actiwatch), which objectively measured sleep, for 3 consecutive days and nights before LVAD implant and at the first and second week and first, third, and sixth month after implantation. During these periods, patients also completed questionnaires on sleep quality and daytime sleepiness. Patients: Twelve of 15 patients completed the 6-month data. Data were analyzed by using descriptive statistics and repeated-measures analysis of variance. Results: We found long sleep onset latencies and low sleep efficiency across time periods. High sleep fragmentation index was noted at baseline and 1 week after LVAD. Short total sleep times, long wake-after-sleep-onset durations, and poor sleep quality were evident at baseline and persisted up to 6 months after LVAD implantation. Low alertness level, a manifestation of sleepiness, was common during late morning to early evening hours. However, only sleep efficiency and wake after sleep onset showed significant changes in pattern (P < .05). Conclusion: Sleep disturbance and daytime sleepiness may be prevalent before and up to 6 months after LVAD implantation, warranting further investigation.

AB - Context: No empirical longitudinal data on sleep and daytime sleepiness patterns in patients with an implantable left ventricular assist device (LVAD) exist. Objective: (1) To describe the sleep patterns (sleep onset latency, sleep efficiency, sleep fragmentation index, total sleep time, and wake after sleep onset), sleep quality, and daytime sleepiness variables and (2) to determine the change in the pattern of these variables before and up to 6 months after LVAD implantation. Design: A longitudinal descriptive repeated-measures design was used. Patients wore wrist actigraphs (AW64 Actiwatch), which objectively measured sleep, for 3 consecutive days and nights before LVAD implant and at the first and second week and first, third, and sixth month after implantation. During these periods, patients also completed questionnaires on sleep quality and daytime sleepiness. Patients: Twelve of 15 patients completed the 6-month data. Data were analyzed by using descriptive statistics and repeated-measures analysis of variance. Results: We found long sleep onset latencies and low sleep efficiency across time periods. High sleep fragmentation index was noted at baseline and 1 week after LVAD. Short total sleep times, long wake-after-sleep-onset durations, and poor sleep quality were evident at baseline and persisted up to 6 months after LVAD implantation. Low alertness level, a manifestation of sleepiness, was common during late morning to early evening hours. However, only sleep efficiency and wake after sleep onset showed significant changes in pattern (P < .05). Conclusion: Sleep disturbance and daytime sleepiness may be prevalent before and up to 6 months after LVAD implantation, warranting further investigation.

UR - http://www.scopus.com/inward/record.url?scp=79961197730&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=79961197730&partnerID=8YFLogxK

U2 - 10.7182/prtr.21.2.cp5874v2l28g62x6

DO - 10.7182/prtr.21.2.cp5874v2l28g62x6

M3 - Article

VL - 21

SP - 131

EP - 136

JO - Progress in Transplantation

JF - Progress in Transplantation

SN - 1526-9248

IS - 2

ER -