Single heartbeat cardiac tagging for the evaluation of transient phenomena

Daniel Herzka, J. Andrew Derbyshire, Peter Kellman, Elliot R. McVeigh

Research output: Contribution to journalArticle

Abstract

Many cardiac abnormalities are of a transient nature, creating a beat-to-beat variation in myocardial function. This work presents the cardiac imaging technique for the measurement of regional function during transient cardiac phenomena. All information necessary for the reconstruction of a cine loop is acquired within a single heartbeat, avoiding the temporal blurring introduced by segmented imaging due to the assumption of cardiac cycle periodicity. This method incorporates a gradient-optimized, high-efficiency EPI-SSFP sequence and TSENSE parallel imaging. For acquisitions with readout resolutions of 128,160, 192, and 256 points, the technique produced images with average temporal resolution of 35, 39, 43, and 52 ms and average spatial resolutions of 2.65, 2.12, 1.77, and 1.32 mm in the readout direction, respectively, and 2.88 and 2.08 mm in the phase encode direction for acceleration rates of 3 and 4, respectively. Local apparent strains in the single slice and measurements of ventricular end-systolic and end-diastolic areas were used as quantitative measures to validate the single heart-beat technique. To demonstrate the utility of the sequence, movie loops were acquired for multiple heartbeats in non-breath-held acquisitions as well as during a Valsalva maneuver. A heartbeat-interleaved acquisition allowed for the reconstruction of nonaccelerated images from R contiguous heartbeats. Images reconstructed from such data displayed tag blurring and reduced tag persistence due to motion and interheartbeat variability. Images acquired during the Valsalva maneuver demonstrated apparent beat-to-beat variability, visible both in the images and as changing strain patterns and ventricular volumes.

Original languageEnglish (US)
Pages (from-to)1455-1464
Number of pages10
JournalMagnetic Resonance in Medicine
Volume54
Issue number6
DOIs
StatePublished - Dec 2005

Fingerprint

Valsalva Maneuver
Cardiac Imaging Techniques
Computer-Assisted Image Processing
Periodicity
Motion Pictures
Direction compound

Keywords

  • Fast cardiac imaging
  • Myocardial function
  • Myocardial tagging
  • Parallel imaging
  • Real time imaging
  • Valsalva maneuver

ASJC Scopus subject areas

  • Radiology Nuclear Medicine and imaging
  • Radiological and Ultrasound Technology

Cite this

Single heartbeat cardiac tagging for the evaluation of transient phenomena. / Herzka, Daniel; Derbyshire, J. Andrew; Kellman, Peter; McVeigh, Elliot R.

In: Magnetic Resonance in Medicine, Vol. 54, No. 6, 12.2005, p. 1455-1464.

Research output: Contribution to journalArticle

Herzka, Daniel ; Derbyshire, J. Andrew ; Kellman, Peter ; McVeigh, Elliot R. / Single heartbeat cardiac tagging for the evaluation of transient phenomena. In: Magnetic Resonance in Medicine. 2005 ; Vol. 54, No. 6. pp. 1455-1464.
@article{370b290e3856411ebad6d82c584973c7,
title = "Single heartbeat cardiac tagging for the evaluation of transient phenomena",
abstract = "Many cardiac abnormalities are of a transient nature, creating a beat-to-beat variation in myocardial function. This work presents the cardiac imaging technique for the measurement of regional function during transient cardiac phenomena. All information necessary for the reconstruction of a cine loop is acquired within a single heartbeat, avoiding the temporal blurring introduced by segmented imaging due to the assumption of cardiac cycle periodicity. This method incorporates a gradient-optimized, high-efficiency EPI-SSFP sequence and TSENSE parallel imaging. For acquisitions with readout resolutions of 128,160, 192, and 256 points, the technique produced images with average temporal resolution of 35, 39, 43, and 52 ms and average spatial resolutions of 2.65, 2.12, 1.77, and 1.32 mm in the readout direction, respectively, and 2.88 and 2.08 mm in the phase encode direction for acceleration rates of 3 and 4, respectively. Local apparent strains in the single slice and measurements of ventricular end-systolic and end-diastolic areas were used as quantitative measures to validate the single heart-beat technique. To demonstrate the utility of the sequence, movie loops were acquired for multiple heartbeats in non-breath-held acquisitions as well as during a Valsalva maneuver. A heartbeat-interleaved acquisition allowed for the reconstruction of nonaccelerated images from R contiguous heartbeats. Images reconstructed from such data displayed tag blurring and reduced tag persistence due to motion and interheartbeat variability. Images acquired during the Valsalva maneuver demonstrated apparent beat-to-beat variability, visible both in the images and as changing strain patterns and ventricular volumes.",
keywords = "Fast cardiac imaging, Myocardial function, Myocardial tagging, Parallel imaging, Real time imaging, Valsalva maneuver",
author = "Daniel Herzka and Derbyshire, {J. Andrew} and Peter Kellman and McVeigh, {Elliot R.}",
year = "2005",
month = "12",
doi = "10.1002/mrm.20719",
language = "English (US)",
volume = "54",
pages = "1455--1464",
journal = "Magnetic Resonance in Medicine",
issn = "0740-3194",
publisher = "John Wiley and Sons Inc.",
number = "6",

}

TY - JOUR

T1 - Single heartbeat cardiac tagging for the evaluation of transient phenomena

AU - Herzka, Daniel

AU - Derbyshire, J. Andrew

AU - Kellman, Peter

AU - McVeigh, Elliot R.

PY - 2005/12

Y1 - 2005/12

N2 - Many cardiac abnormalities are of a transient nature, creating a beat-to-beat variation in myocardial function. This work presents the cardiac imaging technique for the measurement of regional function during transient cardiac phenomena. All information necessary for the reconstruction of a cine loop is acquired within a single heartbeat, avoiding the temporal blurring introduced by segmented imaging due to the assumption of cardiac cycle periodicity. This method incorporates a gradient-optimized, high-efficiency EPI-SSFP sequence and TSENSE parallel imaging. For acquisitions with readout resolutions of 128,160, 192, and 256 points, the technique produced images with average temporal resolution of 35, 39, 43, and 52 ms and average spatial resolutions of 2.65, 2.12, 1.77, and 1.32 mm in the readout direction, respectively, and 2.88 and 2.08 mm in the phase encode direction for acceleration rates of 3 and 4, respectively. Local apparent strains in the single slice and measurements of ventricular end-systolic and end-diastolic areas were used as quantitative measures to validate the single heart-beat technique. To demonstrate the utility of the sequence, movie loops were acquired for multiple heartbeats in non-breath-held acquisitions as well as during a Valsalva maneuver. A heartbeat-interleaved acquisition allowed for the reconstruction of nonaccelerated images from R contiguous heartbeats. Images reconstructed from such data displayed tag blurring and reduced tag persistence due to motion and interheartbeat variability. Images acquired during the Valsalva maneuver demonstrated apparent beat-to-beat variability, visible both in the images and as changing strain patterns and ventricular volumes.

AB - Many cardiac abnormalities are of a transient nature, creating a beat-to-beat variation in myocardial function. This work presents the cardiac imaging technique for the measurement of regional function during transient cardiac phenomena. All information necessary for the reconstruction of a cine loop is acquired within a single heartbeat, avoiding the temporal blurring introduced by segmented imaging due to the assumption of cardiac cycle periodicity. This method incorporates a gradient-optimized, high-efficiency EPI-SSFP sequence and TSENSE parallel imaging. For acquisitions with readout resolutions of 128,160, 192, and 256 points, the technique produced images with average temporal resolution of 35, 39, 43, and 52 ms and average spatial resolutions of 2.65, 2.12, 1.77, and 1.32 mm in the readout direction, respectively, and 2.88 and 2.08 mm in the phase encode direction for acceleration rates of 3 and 4, respectively. Local apparent strains in the single slice and measurements of ventricular end-systolic and end-diastolic areas were used as quantitative measures to validate the single heart-beat technique. To demonstrate the utility of the sequence, movie loops were acquired for multiple heartbeats in non-breath-held acquisitions as well as during a Valsalva maneuver. A heartbeat-interleaved acquisition allowed for the reconstruction of nonaccelerated images from R contiguous heartbeats. Images reconstructed from such data displayed tag blurring and reduced tag persistence due to motion and interheartbeat variability. Images acquired during the Valsalva maneuver demonstrated apparent beat-to-beat variability, visible both in the images and as changing strain patterns and ventricular volumes.

KW - Fast cardiac imaging

KW - Myocardial function

KW - Myocardial tagging

KW - Parallel imaging

KW - Real time imaging

KW - Valsalva maneuver

UR - http://www.scopus.com/inward/record.url?scp=28444498853&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=28444498853&partnerID=8YFLogxK

U2 - 10.1002/mrm.20719

DO - 10.1002/mrm.20719

M3 - Article

C2 - 16265635

AN - SCOPUS:28444498853

VL - 54

SP - 1455

EP - 1464

JO - Magnetic Resonance in Medicine

JF - Magnetic Resonance in Medicine

SN - 0740-3194

IS - 6

ER -