Short echo time proton mr spectroscopic imaging

Stefan Posse, Bernhard Schuknecht, Mary E. Smith, Peter C Van Zijl, Norbert Herschkowitz, Chrit T W Moonen

Research output: Contribution to journalArticle

Abstract

Proton spectroscopic imaging at short TEs (20-30 ms) in human brain requires volume preselection inside the brain to suppress overwhelming lipid and water signals from surrounding tissue. In this article we discuss limitations of conventional volume preselection using stimulated echoes that lead to spectral contamination from surrounding tissue. Improved volume preselection was obtained by adding a complete outer volume suppression (presaturation). The performance of the method is illustrated on normal volunteers and on clinical cases with brain tumors and multiple sclerosis (MS) plaques. In normal human brain, we detected resonances with short T2 values and complex J-coupling, including rather broad methyl/methylene resonances in the chemical shift range between 0 and 2 ppm. Spectroscopic images obtained on patients with intracranial tumors and on one patient with several MS plaques demonstrate the possibility of detecting regional distributions of increased methyl/ methylene resonances between 0 and 2 ppm in brain lesions.

Original languageEnglish (US)
Pages (from-to)1-14
Number of pages14
JournalJournal of Computer Assisted Tomography
Volume17
Issue number1
StatePublished - 1993

Fingerprint

Protons
Brain
Multiple Sclerosis
Brain Neoplasms
Healthy Volunteers
Lipids
Water
Neoplasms

Keywords

  • Brain
  • Magnetic resonance imaging
  • Multiple sclerosis
  • Neoplasms
  • Spectroscopy

ASJC Scopus subject areas

  • Radiology Nuclear Medicine and imaging
  • Radiological and Ultrasound Technology

Cite this

Posse, S., Schuknecht, B., Smith, M. E., Van Zijl, P. C., Herschkowitz, N., & Moonen, C. T. W. (1993). Short echo time proton mr spectroscopic imaging. Journal of Computer Assisted Tomography, 17(1), 1-14.

Short echo time proton mr spectroscopic imaging. / Posse, Stefan; Schuknecht, Bernhard; Smith, Mary E.; Van Zijl, Peter C; Herschkowitz, Norbert; Moonen, Chrit T W.

In: Journal of Computer Assisted Tomography, Vol. 17, No. 1, 1993, p. 1-14.

Research output: Contribution to journalArticle

Posse, S, Schuknecht, B, Smith, ME, Van Zijl, PC, Herschkowitz, N & Moonen, CTW 1993, 'Short echo time proton mr spectroscopic imaging', Journal of Computer Assisted Tomography, vol. 17, no. 1, pp. 1-14.
Posse S, Schuknecht B, Smith ME, Van Zijl PC, Herschkowitz N, Moonen CTW. Short echo time proton mr spectroscopic imaging. Journal of Computer Assisted Tomography. 1993;17(1):1-14.
Posse, Stefan ; Schuknecht, Bernhard ; Smith, Mary E. ; Van Zijl, Peter C ; Herschkowitz, Norbert ; Moonen, Chrit T W. / Short echo time proton mr spectroscopic imaging. In: Journal of Computer Assisted Tomography. 1993 ; Vol. 17, No. 1. pp. 1-14.
@article{d836ee57b97c4b24aa5549dcafc2248e,
title = "Short echo time proton mr spectroscopic imaging",
abstract = "Proton spectroscopic imaging at short TEs (20-30 ms) in human brain requires volume preselection inside the brain to suppress overwhelming lipid and water signals from surrounding tissue. In this article we discuss limitations of conventional volume preselection using stimulated echoes that lead to spectral contamination from surrounding tissue. Improved volume preselection was obtained by adding a complete outer volume suppression (presaturation). The performance of the method is illustrated on normal volunteers and on clinical cases with brain tumors and multiple sclerosis (MS) plaques. In normal human brain, we detected resonances with short T2 values and complex J-coupling, including rather broad methyl/methylene resonances in the chemical shift range between 0 and 2 ppm. Spectroscopic images obtained on patients with intracranial tumors and on one patient with several MS plaques demonstrate the possibility of detecting regional distributions of increased methyl/ methylene resonances between 0 and 2 ppm in brain lesions.",
keywords = "Brain, Magnetic resonance imaging, Multiple sclerosis, Neoplasms, Spectroscopy",
author = "Stefan Posse and Bernhard Schuknecht and Smith, {Mary E.} and {Van Zijl}, {Peter C} and Norbert Herschkowitz and Moonen, {Chrit T W}",
year = "1993",
language = "English (US)",
volume = "17",
pages = "1--14",
journal = "Journal of Computer Assisted Tomography",
issn = "0363-8715",
publisher = "Lippincott Williams and Wilkins",
number = "1",

}

TY - JOUR

T1 - Short echo time proton mr spectroscopic imaging

AU - Posse, Stefan

AU - Schuknecht, Bernhard

AU - Smith, Mary E.

AU - Van Zijl, Peter C

AU - Herschkowitz, Norbert

AU - Moonen, Chrit T W

PY - 1993

Y1 - 1993

N2 - Proton spectroscopic imaging at short TEs (20-30 ms) in human brain requires volume preselection inside the brain to suppress overwhelming lipid and water signals from surrounding tissue. In this article we discuss limitations of conventional volume preselection using stimulated echoes that lead to spectral contamination from surrounding tissue. Improved volume preselection was obtained by adding a complete outer volume suppression (presaturation). The performance of the method is illustrated on normal volunteers and on clinical cases with brain tumors and multiple sclerosis (MS) plaques. In normal human brain, we detected resonances with short T2 values and complex J-coupling, including rather broad methyl/methylene resonances in the chemical shift range between 0 and 2 ppm. Spectroscopic images obtained on patients with intracranial tumors and on one patient with several MS plaques demonstrate the possibility of detecting regional distributions of increased methyl/ methylene resonances between 0 and 2 ppm in brain lesions.

AB - Proton spectroscopic imaging at short TEs (20-30 ms) in human brain requires volume preselection inside the brain to suppress overwhelming lipid and water signals from surrounding tissue. In this article we discuss limitations of conventional volume preselection using stimulated echoes that lead to spectral contamination from surrounding tissue. Improved volume preselection was obtained by adding a complete outer volume suppression (presaturation). The performance of the method is illustrated on normal volunteers and on clinical cases with brain tumors and multiple sclerosis (MS) plaques. In normal human brain, we detected resonances with short T2 values and complex J-coupling, including rather broad methyl/methylene resonances in the chemical shift range between 0 and 2 ppm. Spectroscopic images obtained on patients with intracranial tumors and on one patient with several MS plaques demonstrate the possibility of detecting regional distributions of increased methyl/ methylene resonances between 0 and 2 ppm in brain lesions.

KW - Brain

KW - Magnetic resonance imaging

KW - Multiple sclerosis

KW - Neoplasms

KW - Spectroscopy

UR - http://www.scopus.com/inward/record.url?scp=0027439537&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=0027439537&partnerID=8YFLogxK

M3 - Article

C2 - 8380426

AN - SCOPUS:0027439537

VL - 17

SP - 1

EP - 14

JO - Journal of Computer Assisted Tomography

JF - Journal of Computer Assisted Tomography

SN - 0363-8715

IS - 1

ER -