Reliability of visual field results over repeated testing

Research output: Contribution to journalArticle

Abstract

Fifty-one normal subjects, 337 with ocular hypertension, and 55 patients with glaucoma underwent C-30-2 testing on the Humphrey Field Analyzer on at least three occasions over a 6-year period. The time between tests was approximately 1 year. Using the manufacturer's standard for a reliable field (false-positive and false-negative rates,

Original languageEnglish (US)
Pages (from-to)70-75
Number of pages6
JournalOphthalmology
Volume98
Issue number1
StatePublished - 1991

Fingerprint

Ocular Hypertension
Visual Fields
Glaucoma

ASJC Scopus subject areas

  • Ophthalmology

Cite this

Reliability of visual field results over repeated testing. / Katz, Joanne; Sommer, Alfred; Witt, K.

In: Ophthalmology, Vol. 98, No. 1, 1991, p. 70-75.

Research output: Contribution to journalArticle

@article{94b7c4aa048b4257a5b05c12dd7e495f,
title = "Reliability of visual field results over repeated testing",
abstract = "Fifty-one normal subjects, 337 with ocular hypertension, and 55 patients with glaucoma underwent C-30-2 testing on the Humphrey Field Analyzer on at least three occasions over a 6-year period. The time between tests was approximately 1 year. Using the manufacturer's standard for a reliable field (false-positive and false-negative rates,",
author = "Joanne Katz and Alfred Sommer and K. Witt",
year = "1991",
language = "English (US)",
volume = "98",
pages = "70--75",
journal = "Ophthalmology",
issn = "0161-6420",
publisher = "Elsevier Inc.",
number = "1",

}

TY - JOUR

T1 - Reliability of visual field results over repeated testing

AU - Katz, Joanne

AU - Sommer, Alfred

AU - Witt, K.

PY - 1991

Y1 - 1991

N2 - Fifty-one normal subjects, 337 with ocular hypertension, and 55 patients with glaucoma underwent C-30-2 testing on the Humphrey Field Analyzer on at least three occasions over a 6-year period. The time between tests was approximately 1 year. Using the manufacturer's standard for a reliable field (false-positive and false-negative rates,

AB - Fifty-one normal subjects, 337 with ocular hypertension, and 55 patients with glaucoma underwent C-30-2 testing on the Humphrey Field Analyzer on at least three occasions over a 6-year period. The time between tests was approximately 1 year. Using the manufacturer's standard for a reliable field (false-positive and false-negative rates,

UR - http://www.scopus.com/inward/record.url?scp=0026027455&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=0026027455&partnerID=8YFLogxK

M3 - Article

C2 - 2023736

AN - SCOPUS:0026027455

VL - 98

SP - 70

EP - 75

JO - Ophthalmology

JF - Ophthalmology

SN - 0161-6420

IS - 1

ER -