Registration of EMG Electrodes to Reduce Classification Errors due to Electrode Shift

Cynthia R. Steinhardt, Joseph Bettthauser, Christopher Hunt, Nitish V Thakor

Research output: Chapter in Book/Report/Conference proceedingConference contribution

4 Scopus citations

Abstract

Non-invasive recording of EMG signals from the arm of a typical subject or amputee has been popularized in control of a variety of devices, including upper limb prostheses. One of the most difficult challenges of using external recording devices, such as the Myo Armband, is the need to retrain a movement classifier due to the shift in positions and electrode location around the arm. Electrode shift causes distortion of the features to be extracted for classification and makes previous training unusable. For amputees, this means retraining movement classifiers several times per day. In this experiment, the Myo Armband is used to test the ability to predict the degree of electrode shift from the electrode sites used to originally train a classifier in order to correct by the detected shift and continue to use the same classifer, instead of training a new one. The Myo Armband was rotated around the arm of subjects with intact limbs as they performed six commonly used movements. The mean absolute value of each electrode was used to characterize the response at each electrode site. Shifts in orientation between one position and a new position were identified by minimizing the mean-squared error of their characteristic movement profiles. The correct shift was identified across subjects using only 0.25 s of data with over 90% accuracy using the 'open' or 'wrist supinate' grips. New movements at a shifted location were classified using the feature vectors of a previously collected training set and accounting for the shift; classification error averaged 95.7 ± 0.4%, indicating a possibility for real-time correction of electrode shift error.

Original languageEnglish (US)
Title of host publication2018 IEEE Biomedical Circuits and Systems Conference, BioCAS 2018 - Proceedings
PublisherInstitute of Electrical and Electronics Engineers Inc.
ISBN (Electronic)9781538636039
DOIs
StatePublished - Dec 20 2018
Event2018 IEEE Biomedical Circuits and Systems Conference, BioCAS 2018 - Cleveland, United States
Duration: Oct 17 2018Oct 19 2018

Other

Other2018 IEEE Biomedical Circuits and Systems Conference, BioCAS 2018
Country/TerritoryUnited States
CityCleveland
Period10/17/1810/19/18

ASJC Scopus subject areas

  • Electrical and Electronic Engineering
  • Health Informatics
  • Instrumentation
  • Signal Processing
  • Biomedical Engineering

Fingerprint

Dive into the research topics of 'Registration of EMG Electrodes to Reduce Classification Errors due to Electrode Shift'. Together they form a unique fingerprint.

Cite this