Reduction of RF penetration effects in high field imaging

T. K F Foo, C. E. Hayes, Y. W. Kang

Research output: Contribution to journalArticle

Abstract

A method of correcting for the RF inhomogeneity in the body by dielectric loading of the coil-to-shield space in an RF resonator (coil and shield assembly) is described. The presence of the RF coil and RF shield have significant effects on RF homogeneity. Based on theoretical calculations, a method for adjusting the RF homogeneity by manipulating the axial propagation constant, k(z), is proposed. This is accomplished by loading the coil-to- shield space with dielectric material of suitable relative permittivity so as to increase k(z) and decrease the radial propagation constant, k(ρ). In this manner, the radial wavelength (λ(ρ) = 2π/k(ρ)) can be increased relative to the body dimensions, and the field amplitude variations in the axial plane minimized. Theoretical calculations indicate that a value of between 30 and 40 for the relative permittivity of the dielectric material in the coil-to- shield space would reduce the RF field inhomogeneity from ±15% to about ±3% over a central 30-cm-diameter region of a homogeneous 40-cm-diameter body at both 64 and 170 MHz. The theoretical model was verified in laboratory measurements of the vertical bar |B1| vertical bar field generated in a test coil at 170 MHz which was scaled to correspond to a body at 64 MHz. However, the improved RF field homogeneity would be accompanied by increased RF power requirements and reduced coil sensitivity.

Original languageEnglish (US)
Pages (from-to)287-301
Number of pages15
JournalMagnetic Resonance in Medicine
Volume23
Issue number2
StatePublished - 1992
Externally publishedYes

Fingerprint

Theoretical Models

ASJC Scopus subject areas

  • Radiology Nuclear Medicine and imaging
  • Radiological and Ultrasound Technology

Cite this

Foo, T. K. F., Hayes, C. E., & Kang, Y. W. (1992). Reduction of RF penetration effects in high field imaging. Magnetic Resonance in Medicine, 23(2), 287-301.

Reduction of RF penetration effects in high field imaging. / Foo, T. K F; Hayes, C. E.; Kang, Y. W.

In: Magnetic Resonance in Medicine, Vol. 23, No. 2, 1992, p. 287-301.

Research output: Contribution to journalArticle

Foo, TKF, Hayes, CE & Kang, YW 1992, 'Reduction of RF penetration effects in high field imaging', Magnetic Resonance in Medicine, vol. 23, no. 2, pp. 287-301.
Foo, T. K F ; Hayes, C. E. ; Kang, Y. W. / Reduction of RF penetration effects in high field imaging. In: Magnetic Resonance in Medicine. 1992 ; Vol. 23, No. 2. pp. 287-301.
@article{42fd63b6f0824147abc84ea48bfe1489,
title = "Reduction of RF penetration effects in high field imaging",
abstract = "A method of correcting for the RF inhomogeneity in the body by dielectric loading of the coil-to-shield space in an RF resonator (coil and shield assembly) is described. The presence of the RF coil and RF shield have significant effects on RF homogeneity. Based on theoretical calculations, a method for adjusting the RF homogeneity by manipulating the axial propagation constant, k(z), is proposed. This is accomplished by loading the coil-to- shield space with dielectric material of suitable relative permittivity so as to increase k(z) and decrease the radial propagation constant, k(ρ). In this manner, the radial wavelength (λ(ρ) = 2π/k(ρ)) can be increased relative to the body dimensions, and the field amplitude variations in the axial plane minimized. Theoretical calculations indicate that a value of between 30 and 40 for the relative permittivity of the dielectric material in the coil-to- shield space would reduce the RF field inhomogeneity from ±15{\%} to about ±3{\%} over a central 30-cm-diameter region of a homogeneous 40-cm-diameter body at both 64 and 170 MHz. The theoretical model was verified in laboratory measurements of the vertical bar |B1| vertical bar field generated in a test coil at 170 MHz which was scaled to correspond to a body at 64 MHz. However, the improved RF field homogeneity would be accompanied by increased RF power requirements and reduced coil sensitivity.",
author = "Foo, {T. K F} and Hayes, {C. E.} and Kang, {Y. W.}",
year = "1992",
language = "English (US)",
volume = "23",
pages = "287--301",
journal = "Magnetic Resonance in Medicine",
issn = "0740-3194",
publisher = "John Wiley and Sons Inc.",
number = "2",

}

TY - JOUR

T1 - Reduction of RF penetration effects in high field imaging

AU - Foo, T. K F

AU - Hayes, C. E.

AU - Kang, Y. W.

PY - 1992

Y1 - 1992

N2 - A method of correcting for the RF inhomogeneity in the body by dielectric loading of the coil-to-shield space in an RF resonator (coil and shield assembly) is described. The presence of the RF coil and RF shield have significant effects on RF homogeneity. Based on theoretical calculations, a method for adjusting the RF homogeneity by manipulating the axial propagation constant, k(z), is proposed. This is accomplished by loading the coil-to- shield space with dielectric material of suitable relative permittivity so as to increase k(z) and decrease the radial propagation constant, k(ρ). In this manner, the radial wavelength (λ(ρ) = 2π/k(ρ)) can be increased relative to the body dimensions, and the field amplitude variations in the axial plane minimized. Theoretical calculations indicate that a value of between 30 and 40 for the relative permittivity of the dielectric material in the coil-to- shield space would reduce the RF field inhomogeneity from ±15% to about ±3% over a central 30-cm-diameter region of a homogeneous 40-cm-diameter body at both 64 and 170 MHz. The theoretical model was verified in laboratory measurements of the vertical bar |B1| vertical bar field generated in a test coil at 170 MHz which was scaled to correspond to a body at 64 MHz. However, the improved RF field homogeneity would be accompanied by increased RF power requirements and reduced coil sensitivity.

AB - A method of correcting for the RF inhomogeneity in the body by dielectric loading of the coil-to-shield space in an RF resonator (coil and shield assembly) is described. The presence of the RF coil and RF shield have significant effects on RF homogeneity. Based on theoretical calculations, a method for adjusting the RF homogeneity by manipulating the axial propagation constant, k(z), is proposed. This is accomplished by loading the coil-to- shield space with dielectric material of suitable relative permittivity so as to increase k(z) and decrease the radial propagation constant, k(ρ). In this manner, the radial wavelength (λ(ρ) = 2π/k(ρ)) can be increased relative to the body dimensions, and the field amplitude variations in the axial plane minimized. Theoretical calculations indicate that a value of between 30 and 40 for the relative permittivity of the dielectric material in the coil-to- shield space would reduce the RF field inhomogeneity from ±15% to about ±3% over a central 30-cm-diameter region of a homogeneous 40-cm-diameter body at both 64 and 170 MHz. The theoretical model was verified in laboratory measurements of the vertical bar |B1| vertical bar field generated in a test coil at 170 MHz which was scaled to correspond to a body at 64 MHz. However, the improved RF field homogeneity would be accompanied by increased RF power requirements and reduced coil sensitivity.

UR - http://www.scopus.com/inward/record.url?scp=0026567364&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=0026567364&partnerID=8YFLogxK

M3 - Article

C2 - 1549043

AN - SCOPUS:0026567364

VL - 23

SP - 287

EP - 301

JO - Magnetic Resonance in Medicine

JF - Magnetic Resonance in Medicine

SN - 0740-3194

IS - 2

ER -