Recent studies have illustrated that motion-related artifacts remain in resting-state fMRI (rs-fMRI) data even after common corrective processing procedures have been applied, but the extent to which head motion distorts the data may be modulated by the corrective approach taken. We compare two different methods for estimating nuisance signals from tissues not expected to exhibit BOLD fMRI signals of neuronal origin: 1) the more commonly used mean signal method and 2) the principal components analysis approach (aCompCor: Behzadi et al., 2007). Further, we investigate the added benefit of "scrubbing" (Power et al., 2012) following both methods. We demonstrate that the use of aCompCor removes motion artifacts more effectively than tissue-mean signal regression. In addition, inclusion of more components from anatomically defined regions of no interest better mitigates motion-related artifacts and improves the specificity of functional connectivity estimates. While scrubbing further attenuates motion-related artifacts when mean signals are used, scrubbing provides no additional benefit in terms of motion artifact reduction or connectivity specificity when using aCompCor.

Original languageEnglish (US)
Pages (from-to)22-35
Number of pages14
JournalNeuroImage
Volume96
DOIs
StatePublished - Aug 1 2014

Fingerprint

Artifacts
Magnetic Resonance Imaging
Principal Component Analysis
Head

Keywords

  • Head motion
  • Nuisance regression
  • Resting state fMRI
  • Specificity

ASJC Scopus subject areas

  • Cognitive Neuroscience
  • Neurology
  • Medicine(all)

Cite this

Reduction of motion-related artifacts in resting state fMRI using aCompCor. / Muschelli, John; Nebel, Mary Beth; Caffo, Brian S; Barber, Anita D.; Pekar, James J; Mostofsky, Stewart H.

In: NeuroImage, Vol. 96, 01.08.2014, p. 22-35.

Research output: Contribution to journalArticle

@article{c045f77762a547ef8cc158c08fc9e73f,
title = "Reduction of motion-related artifacts in resting state fMRI using aCompCor",
abstract = "Recent studies have illustrated that motion-related artifacts remain in resting-state fMRI (rs-fMRI) data even after common corrective processing procedures have been applied, but the extent to which head motion distorts the data may be modulated by the corrective approach taken. We compare two different methods for estimating nuisance signals from tissues not expected to exhibit BOLD fMRI signals of neuronal origin: 1) the more commonly used mean signal method and 2) the principal components analysis approach (aCompCor: Behzadi et al., 2007). Further, we investigate the added benefit of {"}scrubbing{"} (Power et al., 2012) following both methods. We demonstrate that the use of aCompCor removes motion artifacts more effectively than tissue-mean signal regression. In addition, inclusion of more components from anatomically defined regions of no interest better mitigates motion-related artifacts and improves the specificity of functional connectivity estimates. While scrubbing further attenuates motion-related artifacts when mean signals are used, scrubbing provides no additional benefit in terms of motion artifact reduction or connectivity specificity when using aCompCor.",
keywords = "Head motion, Nuisance regression, Resting state fMRI, Specificity",
author = "John Muschelli and Nebel, {Mary Beth} and Caffo, {Brian S} and Barber, {Anita D.} and Pekar, {James J} and Mostofsky, {Stewart H}",
year = "2014",
month = "8",
day = "1",
doi = "10.1016/j.neuroimage.2014.03.028",
language = "English (US)",
volume = "96",
pages = "22--35",
journal = "NeuroImage",
issn = "1053-8119",
publisher = "Academic Press Inc.",

}

TY - JOUR

T1 - Reduction of motion-related artifacts in resting state fMRI using aCompCor

AU - Muschelli, John

AU - Nebel, Mary Beth

AU - Caffo, Brian S

AU - Barber, Anita D.

AU - Pekar, James J

AU - Mostofsky, Stewart H

PY - 2014/8/1

Y1 - 2014/8/1

N2 - Recent studies have illustrated that motion-related artifacts remain in resting-state fMRI (rs-fMRI) data even after common corrective processing procedures have been applied, but the extent to which head motion distorts the data may be modulated by the corrective approach taken. We compare two different methods for estimating nuisance signals from tissues not expected to exhibit BOLD fMRI signals of neuronal origin: 1) the more commonly used mean signal method and 2) the principal components analysis approach (aCompCor: Behzadi et al., 2007). Further, we investigate the added benefit of "scrubbing" (Power et al., 2012) following both methods. We demonstrate that the use of aCompCor removes motion artifacts more effectively than tissue-mean signal regression. In addition, inclusion of more components from anatomically defined regions of no interest better mitigates motion-related artifacts and improves the specificity of functional connectivity estimates. While scrubbing further attenuates motion-related artifacts when mean signals are used, scrubbing provides no additional benefit in terms of motion artifact reduction or connectivity specificity when using aCompCor.

AB - Recent studies have illustrated that motion-related artifacts remain in resting-state fMRI (rs-fMRI) data even after common corrective processing procedures have been applied, but the extent to which head motion distorts the data may be modulated by the corrective approach taken. We compare two different methods for estimating nuisance signals from tissues not expected to exhibit BOLD fMRI signals of neuronal origin: 1) the more commonly used mean signal method and 2) the principal components analysis approach (aCompCor: Behzadi et al., 2007). Further, we investigate the added benefit of "scrubbing" (Power et al., 2012) following both methods. We demonstrate that the use of aCompCor removes motion artifacts more effectively than tissue-mean signal regression. In addition, inclusion of more components from anatomically defined regions of no interest better mitigates motion-related artifacts and improves the specificity of functional connectivity estimates. While scrubbing further attenuates motion-related artifacts when mean signals are used, scrubbing provides no additional benefit in terms of motion artifact reduction or connectivity specificity when using aCompCor.

KW - Head motion

KW - Nuisance regression

KW - Resting state fMRI

KW - Specificity

UR - http://www.scopus.com/inward/record.url?scp=84899895896&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=84899895896&partnerID=8YFLogxK

U2 - 10.1016/j.neuroimage.2014.03.028

DO - 10.1016/j.neuroimage.2014.03.028

M3 - Article

C2 - 24657780

AN - SCOPUS:84899895896

VL - 96

SP - 22

EP - 35

JO - NeuroImage

JF - NeuroImage

SN - 1053-8119

ER -