Recombinant human thyroid-stimulating hormone versus thyroid hormone withdrawal in 124I PET/CT-based dosimetry for 131I therapy of metastatic differentiated thyroid cancer

Donika Plyku, Robert F. Hobbs, Kevin Huang, Frank Atkins, Carlos Garcia, George Sgouros, Douglas Van Nostrand

Research output: Contribution to journalArticlepeer-review

18 Scopus citations

Abstract

Patients with metastatic differentiated thyroid cancer (DTC) may be prepared using either thyroid-stimulating hormone withdrawal (THW) or recombinant human thyroid-stimulating hormone (rhTSH) injections before 131I administration for treatment. The objective of this study was to compare the absorbed dose to the critical organs and tumors determined by 124I PET/CT-based dosimetry for 131I therapy of metastatic DTC when the same patient was prepared with and imaged after both THW and rhTSH injections. Methods: Four DTC patients at MedStar Washington Hospital Center were first prepared using the rhTSH method and imaged by 124I PET/CT at 2, 24, 48, 72, and 96 h after administration of approximately 30-63 MBq of 124I. After 5-8 wk, the same patients were prepared using the THW method and imaged as before. The 124I PET/CT images acquired as part of a prospective study were used to perform retrospective dosimetric calculations for 131I therapy for the normal organs with the dosimetry package 3D-RD. The absorbed doses from 131I for the lungs, liver, heart, kidneys, and bone marrow were obtained for each study (rhTSH and THW). Twenty-two lesions in 3 patients were identified. The contours were drawn on each PET image of each study. Time-integrated activity coefficients were calculated and used as input in OLINDA/EXM sphere dose calculator to obtain the absorbed dose to tumors. Results: The THW-to-rhTSH organ absorbed dose ratio averaged over 5 organs for the first 3 patients was 1.5, 2.5, and 0.64, respectively, and averaged over 3 organs for the fourth patient was 1.1. The absorbed dose per unit administered activity to the bone marrow was 0.13, 0.086, 0.33, and 0.068 mGy/MBq after rhTSH and 0.11, 0.14, 0.22, and 0.080 mGy/MBq after THW for each patient, respectively. With the exception of 3 lesions of 1 patient, the absorbed dose per unit administered activity of 131I was higher in the THW study than in the rhTSH study. The ratio of the average tumor absorbed dose after stimulation by THW compared with stimulation by rhTSH injections was 3.9, 27, and 1.4 for patient 1, patient 2, and patient 3, respectively. The ratio of mean tumor to bone marrow absorbed dose per unit administered activity of 131I, after THW and rhTSH, was 232 and 62 (patient 1), 12 and 0.78 (patient 2), and 22 and 11 (patient 3), respectively. Conclusion: The results suggest a high patient variability in the overall absorbed dose to the normal organs per MBq of 131I administered, between the 2 TSH stimulation methods. The tumor-to-dose-limiting-organ (bone marrow) absorbed dose ratio, that is, the therapeutic index, was higher in the THW-aided than rhTSH-aided administrations. Additional comparison for tumor and normal organ absorbed dose in patients prepared using both methods is needed before definitive conclusions may be drawn regarding rhTSH versus THW patient preparation methods for 131I therapy of metastatic DTC.

Original languageEnglish (US)
Pages (from-to)1146-1154
Number of pages9
JournalJournal of Nuclear Medicine
Volume58
Issue number7
DOIs
StatePublished - Jul 1 2017

Keywords

  • Differentiated thyroid cancer
  • Dosimetry
  • Imaging
  • Radionuclide therapy
  • Radiopharmaceuticals

ASJC Scopus subject areas

  • Radiology Nuclear Medicine and imaging

Fingerprint

Dive into the research topics of 'Recombinant human thyroid-stimulating hormone versus thyroid hormone withdrawal in 124I PET/CT-based dosimetry for 131I therapy of metastatic differentiated thyroid cancer'. Together they form a unique fingerprint.

Cite this