Because of the concerns associated with radiation exposure at a young age, there is an increased interest in pediatric absorbed dose estimates for imaging agents. Almost all reported pediatric absorbed dose estimates, however, have been determined using adult pharmacokinetic data with radionuclide S values that take into account the anatomical differences between adults and children based upon the older Cristy-Eckerman (C-E) stylized phantoms. In this work, we use pediatric model-derived pharmacokinetics to compare absorbed dose and effective dose estimates for 18F-FDG in pediatric patients using S values generated from two different geometries of computational phantoms. Time-integrated activity coefficients of 18F-FDG in brain, lungs, heart wall, kidneys and liver, retrospectively, calculated from 35 pediatric patients at the Boston's Children Hospital were used. The absorbed dose calculation was performed in accordance with the Medical Internal Radiation Dose method using S values generated from the University of Florida/National Cancer Institute (UF/NCI) hybrid phantoms, as well as those from C-E stylized computational phantoms. The effective dose was computed using tissue-weighting factors from ICRP Publication 60 and ICRP Publication 103 for the C-E and UF/NCI, respectively. Substantial differences in the absorbed dose estimates between UF/NCI hybrid pediatric phantoms and the C-E stylized phantoms were found for the lungs, ovaries, red bone marrow and urinary bladder wall. Large discrepancies in the calculated dose values were observed in the bone marrow; ranging between -26% to +199%. The effective doses computed by the UF/NCI hybrid phantom S values were slightly different than those seen using the C-E stylized phantoms with percent differences of -0.7%, 2.9% and 2.5% for a newborn, 1 year old and 5 year old, respectively. Differences in anatomical modeling features among computational phantoms used to perform Monte Carlo-based photon and electron transport simulations for 18F, and very likely for other radionuclides, impact internal organ dosimetry computations for pediatric nuclear medicine studies.

Original languageEnglish (US)
Article number165012
JournalPhysics in Medicine and Biology
Volume63
Issue number16
DOIs
StatePublished - Aug 14 2018

Fingerprint

National Cancer Institute (U.S.)
Fluorodeoxyglucose F18
Pediatrics
Bone Marrow
Radioisotopes
Publications
Pharmacokinetics
Lung
Nuclear Medicine
Thromboplastin
Electron Transport
Photons
Ovary
Urinary Bladder
Newborn Infant
Radiation
Kidney
Liver
Brain

Keywords

  • F-FDG
  • computational phantoms
  • Medical Internal Radiation Dose (MIRD)
  • Monte Carlo calculations
  • pediatric dosimetry

ASJC Scopus subject areas

  • Radiological and Ultrasound Technology
  • Radiology Nuclear Medicine and imaging

Cite this

Re-evaluation of pediatric 18F-FDG dosimetry : Cristy-Eckerman versus UF/NCI hybrid computational phantoms. / Khamwan, Kitiwat; O'Reilly, Shannon E.; Plyku, Donika; Goodkind, Alison; Josefsson, Nils Anders Mauritz; Cao, Xinhua; Fahey, Frederic H.; Treves, S. Ted; Bolch, Wesley E.; Sgouros, George.

In: Physics in Medicine and Biology, Vol. 63, No. 16, 165012, 14.08.2018.

Research output: Contribution to journalArticle

Khamwan, Kitiwat ; O'Reilly, Shannon E. ; Plyku, Donika ; Goodkind, Alison ; Josefsson, Nils Anders Mauritz ; Cao, Xinhua ; Fahey, Frederic H. ; Treves, S. Ted ; Bolch, Wesley E. ; Sgouros, George. / Re-evaluation of pediatric 18F-FDG dosimetry : Cristy-Eckerman versus UF/NCI hybrid computational phantoms. In: Physics in Medicine and Biology. 2018 ; Vol. 63, No. 16.
@article{ed80aab92d5746b3987814001b239b4a,
title = "Re-evaluation of pediatric 18F-FDG dosimetry: Cristy-Eckerman versus UF/NCI hybrid computational phantoms",
abstract = "Because of the concerns associated with radiation exposure at a young age, there is an increased interest in pediatric absorbed dose estimates for imaging agents. Almost all reported pediatric absorbed dose estimates, however, have been determined using adult pharmacokinetic data with radionuclide S values that take into account the anatomical differences between adults and children based upon the older Cristy-Eckerman (C-E) stylized phantoms. In this work, we use pediatric model-derived pharmacokinetics to compare absorbed dose and effective dose estimates for 18F-FDG in pediatric patients using S values generated from two different geometries of computational phantoms. Time-integrated activity coefficients of 18F-FDG in brain, lungs, heart wall, kidneys and liver, retrospectively, calculated from 35 pediatric patients at the Boston's Children Hospital were used. The absorbed dose calculation was performed in accordance with the Medical Internal Radiation Dose method using S values generated from the University of Florida/National Cancer Institute (UF/NCI) hybrid phantoms, as well as those from C-E stylized computational phantoms. The effective dose was computed using tissue-weighting factors from ICRP Publication 60 and ICRP Publication 103 for the C-E and UF/NCI, respectively. Substantial differences in the absorbed dose estimates between UF/NCI hybrid pediatric phantoms and the C-E stylized phantoms were found for the lungs, ovaries, red bone marrow and urinary bladder wall. Large discrepancies in the calculated dose values were observed in the bone marrow; ranging between -26{\%} to +199{\%}. The effective doses computed by the UF/NCI hybrid phantom S values were slightly different than those seen using the C-E stylized phantoms with percent differences of -0.7{\%}, 2.9{\%} and 2.5{\%} for a newborn, 1 year old and 5 year old, respectively. Differences in anatomical modeling features among computational phantoms used to perform Monte Carlo-based photon and electron transport simulations for 18F, and very likely for other radionuclides, impact internal organ dosimetry computations for pediatric nuclear medicine studies.",
keywords = "F-FDG, computational phantoms, Medical Internal Radiation Dose (MIRD), Monte Carlo calculations, pediatric dosimetry",
author = "Kitiwat Khamwan and O'Reilly, {Shannon E.} and Donika Plyku and Alison Goodkind and Josefsson, {Nils Anders Mauritz} and Xinhua Cao and Fahey, {Frederic H.} and Treves, {S. Ted} and Bolch, {Wesley E.} and George Sgouros",
year = "2018",
month = "8",
day = "14",
doi = "10.1088/1361-6560/aad47a",
language = "English (US)",
volume = "63",
journal = "Physics in Medicine and Biology",
issn = "0031-9155",
publisher = "IOP Publishing Ltd.",
number = "16",

}

TY - JOUR

T1 - Re-evaluation of pediatric 18F-FDG dosimetry

T2 - Cristy-Eckerman versus UF/NCI hybrid computational phantoms

AU - Khamwan, Kitiwat

AU - O'Reilly, Shannon E.

AU - Plyku, Donika

AU - Goodkind, Alison

AU - Josefsson, Nils Anders Mauritz

AU - Cao, Xinhua

AU - Fahey, Frederic H.

AU - Treves, S. Ted

AU - Bolch, Wesley E.

AU - Sgouros, George

PY - 2018/8/14

Y1 - 2018/8/14

N2 - Because of the concerns associated with radiation exposure at a young age, there is an increased interest in pediatric absorbed dose estimates for imaging agents. Almost all reported pediatric absorbed dose estimates, however, have been determined using adult pharmacokinetic data with radionuclide S values that take into account the anatomical differences between adults and children based upon the older Cristy-Eckerman (C-E) stylized phantoms. In this work, we use pediatric model-derived pharmacokinetics to compare absorbed dose and effective dose estimates for 18F-FDG in pediatric patients using S values generated from two different geometries of computational phantoms. Time-integrated activity coefficients of 18F-FDG in brain, lungs, heart wall, kidneys and liver, retrospectively, calculated from 35 pediatric patients at the Boston's Children Hospital were used. The absorbed dose calculation was performed in accordance with the Medical Internal Radiation Dose method using S values generated from the University of Florida/National Cancer Institute (UF/NCI) hybrid phantoms, as well as those from C-E stylized computational phantoms. The effective dose was computed using tissue-weighting factors from ICRP Publication 60 and ICRP Publication 103 for the C-E and UF/NCI, respectively. Substantial differences in the absorbed dose estimates between UF/NCI hybrid pediatric phantoms and the C-E stylized phantoms were found for the lungs, ovaries, red bone marrow and urinary bladder wall. Large discrepancies in the calculated dose values were observed in the bone marrow; ranging between -26% to +199%. The effective doses computed by the UF/NCI hybrid phantom S values were slightly different than those seen using the C-E stylized phantoms with percent differences of -0.7%, 2.9% and 2.5% for a newborn, 1 year old and 5 year old, respectively. Differences in anatomical modeling features among computational phantoms used to perform Monte Carlo-based photon and electron transport simulations for 18F, and very likely for other radionuclides, impact internal organ dosimetry computations for pediatric nuclear medicine studies.

AB - Because of the concerns associated with radiation exposure at a young age, there is an increased interest in pediatric absorbed dose estimates for imaging agents. Almost all reported pediatric absorbed dose estimates, however, have been determined using adult pharmacokinetic data with radionuclide S values that take into account the anatomical differences between adults and children based upon the older Cristy-Eckerman (C-E) stylized phantoms. In this work, we use pediatric model-derived pharmacokinetics to compare absorbed dose and effective dose estimates for 18F-FDG in pediatric patients using S values generated from two different geometries of computational phantoms. Time-integrated activity coefficients of 18F-FDG in brain, lungs, heart wall, kidneys and liver, retrospectively, calculated from 35 pediatric patients at the Boston's Children Hospital were used. The absorbed dose calculation was performed in accordance with the Medical Internal Radiation Dose method using S values generated from the University of Florida/National Cancer Institute (UF/NCI) hybrid phantoms, as well as those from C-E stylized computational phantoms. The effective dose was computed using tissue-weighting factors from ICRP Publication 60 and ICRP Publication 103 for the C-E and UF/NCI, respectively. Substantial differences in the absorbed dose estimates between UF/NCI hybrid pediatric phantoms and the C-E stylized phantoms were found for the lungs, ovaries, red bone marrow and urinary bladder wall. Large discrepancies in the calculated dose values were observed in the bone marrow; ranging between -26% to +199%. The effective doses computed by the UF/NCI hybrid phantom S values were slightly different than those seen using the C-E stylized phantoms with percent differences of -0.7%, 2.9% and 2.5% for a newborn, 1 year old and 5 year old, respectively. Differences in anatomical modeling features among computational phantoms used to perform Monte Carlo-based photon and electron transport simulations for 18F, and very likely for other radionuclides, impact internal organ dosimetry computations for pediatric nuclear medicine studies.

KW - F-FDG

KW - computational phantoms

KW - Medical Internal Radiation Dose (MIRD)

KW - Monte Carlo calculations

KW - pediatric dosimetry

UR - http://www.scopus.com/inward/record.url?scp=85052516073&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=85052516073&partnerID=8YFLogxK

U2 - 10.1088/1361-6560/aad47a

DO - 10.1088/1361-6560/aad47a

M3 - Article

C2 - 30022768

AN - SCOPUS:85052516073

VL - 63

JO - Physics in Medicine and Biology

JF - Physics in Medicine and Biology

SN - 0031-9155

IS - 16

M1 - 165012

ER -