Quantitative analysis of first-pass contrast-enhanced myocardial perfusion multidetector CT using a patlak plot method and extraction fraction correction during adenosine stress

Takashi Ichihara, Richard George, Joao A.C. Lima, Albert C. Lardo

Research output: Chapter in Book/Report/Conference proceedingConference contribution

7 Scopus citations

Abstract

The purpose of this study was to develop a quantitative method for myocardial blood flow (MBF) measurement that can be used to derive accurate myocardial perfusion measurements from dynamic multidetector computed tomography (MDCT) images by using a compartment model for calculating the first-order transfer constant (K1) with correction for the capillary transit extraction fraction (E). Six canine models of left anterior descending (LAD) artery stenosis were prepared and underwent first-pass contrast-enhanced MDCT perfusion imaging during adenosine infusion (0.14-0.21 mg/kg/min). K1, which is the first-order transfer constant from left ventricular (LV) blood to myocardium, was measured using the Patlak plot method applied to time-density curve data of the LV blood pool and myocardium. The results were compared against microsphere MBF measurements, and the extraction fraction of contrast agent was calculated. K1 is related to the regional MBF as K 1=EF, E=(1-exp(-PS/F)), where PS is the permeability-surface area product and F is myocardial flow. Based on the above relationship, a look-up table from K1 to MBF can be generated and Patlak plot-derived K 1 values can be converted to the calculated MBF. The calculated MBF and microsphere MBF showed a strong linear association. The extraction fraction in dogs as a function of flow (F) was E=(1-exp(-(0.253F+0.7871)/F)). Regional MBF can be measured accurately using the Patlak plot method based on a compartment model and look-up table with extraction fraction correction from K1 to MBF.

Original languageEnglish (US)
Title of host publication2009 IEEE Nuclear Science Symposium Conference Record, NSS/MIC 2009
Pages3849-3852
Number of pages4
DOIs
StatePublished - Dec 1 2009
Event2009 IEEE Nuclear Science Symposium Conference Record, NSS/MIC 2009 - Orlando, FL, United States
Duration: Oct 25 2009Oct 31 2009

Publication series

NameIEEE Nuclear Science Symposium Conference Record
ISSN (Print)1095-7863

Other

Other2009 IEEE Nuclear Science Symposium Conference Record, NSS/MIC 2009
Country/TerritoryUnited States
CityOrlando, FL
Period10/25/0910/31/09

ASJC Scopus subject areas

  • Radiation
  • Nuclear and High Energy Physics
  • Radiology Nuclear Medicine and imaging

Fingerprint

Dive into the research topics of 'Quantitative analysis of first-pass contrast-enhanced myocardial perfusion multidetector CT using a patlak plot method and extraction fraction correction during adenosine stress'. Together they form a unique fingerprint.

Cite this