TY - JOUR
T1 - Qualitative and Quantitative Analysis of the Corneal Endothelium With Smartphone Specular Microscopy
AU - Fliotsos, Michael J.
AU - Deljookorani, Shiva
AU - Dzhaber, Daliya
AU - Chandan, Subhangi
AU - Ighani, Mehrnaz
AU - Eghrari, Allen O.
PY - 2020/7/1
Y1 - 2020/7/1
N2 - PURPOSE: We sought to demonstrate the feasibility of a lower-cost, portable method for qualitative and quantitative analysis of the corneal endothelium using a smartphone and slit-lamp biomicroscope. METHODS: In this study, at a single academic center, we recruited healthy participants to undergo imaging of the corneal endothelium using both a smartphone-based method and a specular microscope. Participants first had their eyes imaged with a CellChek NSP-9900 Specular Microscope (Konan Medical, Inc, Irvine, CA). For image capture on the smartphone, a beam of light approximately 0.2 mm in diameter was directed to the center of the cornea with a slit-lamp biomicroscope to achieve specular reflection. With 40× zoom on the slit-lamp and 4K video mode set on an iPhone 7 Plus held to an ocular, the corneal endothelium was recorded until the hexagonal pattern of cells was identified and the sharpest frame from the video was selected. RESULTS: The videos were analyzed from 14 sets of eyes (average length 2 minutes 40 seconds). The average intraclass correlation coefficient was 0.67 (95% confidence interval, 0.43-0.82). The mean difference between smartphone endothelial cell count and specular endothelial cell count was -209 cells/mm (SD = 483 cells/mm), which did not achieve significance (P = 0.14). A Bland-Altman analysis with simple linear regression showed no proportional bias when comparing the 2 modalities (coefficient = -0.20; t-value = -0.42; P = 0.68). CONCLUSIONS: Smartphone specular microscopy is capable of qualitative and quantitative analysis of the corneal endothelium. Further refinement to standardize the light source and automate analysis will increase feasibility.
AB - PURPOSE: We sought to demonstrate the feasibility of a lower-cost, portable method for qualitative and quantitative analysis of the corneal endothelium using a smartphone and slit-lamp biomicroscope. METHODS: In this study, at a single academic center, we recruited healthy participants to undergo imaging of the corneal endothelium using both a smartphone-based method and a specular microscope. Participants first had their eyes imaged with a CellChek NSP-9900 Specular Microscope (Konan Medical, Inc, Irvine, CA). For image capture on the smartphone, a beam of light approximately 0.2 mm in diameter was directed to the center of the cornea with a slit-lamp biomicroscope to achieve specular reflection. With 40× zoom on the slit-lamp and 4K video mode set on an iPhone 7 Plus held to an ocular, the corneal endothelium was recorded until the hexagonal pattern of cells was identified and the sharpest frame from the video was selected. RESULTS: The videos were analyzed from 14 sets of eyes (average length 2 minutes 40 seconds). The average intraclass correlation coefficient was 0.67 (95% confidence interval, 0.43-0.82). The mean difference between smartphone endothelial cell count and specular endothelial cell count was -209 cells/mm (SD = 483 cells/mm), which did not achieve significance (P = 0.14). A Bland-Altman analysis with simple linear regression showed no proportional bias when comparing the 2 modalities (coefficient = -0.20; t-value = -0.42; P = 0.68). CONCLUSIONS: Smartphone specular microscopy is capable of qualitative and quantitative analysis of the corneal endothelium. Further refinement to standardize the light source and automate analysis will increase feasibility.
UR - http://www.scopus.com/inward/record.url?scp=85086284241&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=85086284241&partnerID=8YFLogxK
U2 - 10.1097/ICO.0000000000002277
DO - 10.1097/ICO.0000000000002277
M3 - Article
C2 - 32068608
AN - SCOPUS:85086284241
SN - 0277-3740
VL - 39
SP - 924
EP - 929
JO - Cornea
JF - Cornea
IS - 7
ER -