The success of prostate brachytherapy depends on the faithful delivery of a dose plan. In turn, intraoperative localization and visualization of the implanted radioactive brachytherapy seeds enables more proficient and informed adjustments to the executed plan during therapy. Prior work has demonstrated adequate seed reconstructions from uncalibrated mobile c-arms using either external tracking devices or image-based fiducials for c-arm pose determination. These alternatives are either time-consuming or interfere with the clinical flow of the surgery, or both. This paper describes a seed reconstruction approach that avoids both tracking devices and fiducials. Instead, it uses the preoperative dose plan in conjunction with a set of captured images to get initial estimates of the c-arm poses followed by an auto-focus technique using the seeds themselves as fiducials to refine the pose estimates. Intraoperative seed localization is achieved through iteratively solving for poses and seed correspondences across images and reconstructing the 3D implanted seeds. The feasibility of this approach was demonstrated through a series of simulations involving variable noise levels, seed densities, image separability and number of images. Preliminary results indicate mean reconstruction errors within 1.2 mm for noisy plans of 84 seeds or fewer. These are attained for additive noise whose standard deviation of the 3D mean error introduced to the plan to simulate the implant is within 3.2 mm.

Original languageEnglish (US)
Title of host publicationMedical Imaging 2009
Subtitle of host publicationVisualization, Image-Guided Procedures, and Modeling
DOIs
StatePublished - Jun 19 2009
EventMedical Imaging 2009: Biomedical Applications in Molecular, Structural, and Functional Imaging - Lake Buena Vista, FL, United States
Duration: Feb 8 2009Feb 10 2009

Publication series

NameProgress in Biomedical Optics and Imaging - Proceedings of SPIE
Volume7261
ISSN (Print)1605-7422

Other

OtherMedical Imaging 2009: Biomedical Applications in Molecular, Structural, and Functional Imaging
CountryUnited States
CityLake Buena Vista, FL
Period2/8/092/10/09

    Fingerprint

Keywords

  • Image-guided therapy
  • Intraoperative Imaging
  • Pelvic procedures
  • Prostate brachytherapy
  • Reconstruction
  • Registration

ASJC Scopus subject areas

  • Electronic, Optical and Magnetic Materials
  • Biomaterials
  • Atomic and Molecular Physics, and Optics
  • Radiology Nuclear Medicine and imaging

Cite this

Ayada, M. S., Lee, J., Prince, J. L., & Fichtinger, G. (2009). Prostate brachytherapy seed localization using a mobile c-arm without tracking. In Medical Imaging 2009: Visualization, Image-Guided Procedures, and Modeling [72611K] (Progress in Biomedical Optics and Imaging - Proceedings of SPIE; Vol. 7261). https://doi.org/10.1117/12.811225