Position-dependent image characteristics of a CCD-based full-field digital mammography system

Hangyi Jiang, Wei R. Chen, Hong Liu

Research output: Contribution to journalArticle

Abstract

Full-field digital mammography imaging systems have been investigated extensively. However, most investigations focus on the quality assessment of the entire image. In this article, we present the results of experimental measurements on the position-dependent image characteristics of a CCD array-based digital imaging system. Objective image quality parameters such as noise power spectrum (NPS) and signal-to-noise ratio (SNR), which are also frequency-dependent, are employed for this investigation. The image detector uses 12 CCDs arranged in a 4 × 3 array to cover a field of 18 cm × 24 cm with a single x-ray exposure. Totally 18 sub-areas were chosen as the regions-of-interest (ROIs) for each full-field image to study position-dependent characteristics. Our experimental results indicate that the image quality at different positions of the full-field image exhibit slightly variance due to the characteristic diversity of the CCDs and due to the oblique angle of the ROIs to the x-ray source. The image seams caused by the physical gaps between adjacent CCDs do not increase the noise components significantly to the composite full-field image. The x-ray energy-dependence of NPS and SNR was also studied.

Original languageEnglish (US)
Pages (from-to)101-111
Number of pages11
JournalJournal of X-Ray Science and Technology
Volume9
Issue number3-4
StatePublished - 2001
Externally publishedYes

Fingerprint

digital systems
Mammography
Charge coupled devices
charge coupled devices
X-Rays
Signal-To-Noise Ratio
Power spectrum
X rays
Imaging systems
Image quality
Signal to noise ratio
Noise
noise spectra
power spectra
signal to noise ratios
Detectors
Composite materials
x ray sources
x rays
composite materials

Keywords

  • Digital radiography
  • Full-field mammography systems
  • Image quality
  • Modulation transfer function
  • Noise power spectra
  • Signal-to-noise ratio

ASJC Scopus subject areas

  • Radiology Nuclear Medicine and imaging

Cite this

Position-dependent image characteristics of a CCD-based full-field digital mammography system. / Jiang, Hangyi; Chen, Wei R.; Liu, Hong.

In: Journal of X-Ray Science and Technology, Vol. 9, No. 3-4, 2001, p. 101-111.

Research output: Contribution to journalArticle

@article{7198b54ff3ed4635aeb29c97926d131c,
title = "Position-dependent image characteristics of a CCD-based full-field digital mammography system",
abstract = "Full-field digital mammography imaging systems have been investigated extensively. However, most investigations focus on the quality assessment of the entire image. In this article, we present the results of experimental measurements on the position-dependent image characteristics of a CCD array-based digital imaging system. Objective image quality parameters such as noise power spectrum (NPS) and signal-to-noise ratio (SNR), which are also frequency-dependent, are employed for this investigation. The image detector uses 12 CCDs arranged in a 4 × 3 array to cover a field of 18 cm × 24 cm with a single x-ray exposure. Totally 18 sub-areas were chosen as the regions-of-interest (ROIs) for each full-field image to study position-dependent characteristics. Our experimental results indicate that the image quality at different positions of the full-field image exhibit slightly variance due to the characteristic diversity of the CCDs and due to the oblique angle of the ROIs to the x-ray source. The image seams caused by the physical gaps between adjacent CCDs do not increase the noise components significantly to the composite full-field image. The x-ray energy-dependence of NPS and SNR was also studied.",
keywords = "Digital radiography, Full-field mammography systems, Image quality, Modulation transfer function, Noise power spectra, Signal-to-noise ratio",
author = "Hangyi Jiang and Chen, {Wei R.} and Hong Liu",
year = "2001",
language = "English (US)",
volume = "9",
pages = "101--111",
journal = "Journal of X-Ray Science and Technology",
issn = "0895-3996",
publisher = "IOS Press",
number = "3-4",

}

TY - JOUR

T1 - Position-dependent image characteristics of a CCD-based full-field digital mammography system

AU - Jiang, Hangyi

AU - Chen, Wei R.

AU - Liu, Hong

PY - 2001

Y1 - 2001

N2 - Full-field digital mammography imaging systems have been investigated extensively. However, most investigations focus on the quality assessment of the entire image. In this article, we present the results of experimental measurements on the position-dependent image characteristics of a CCD array-based digital imaging system. Objective image quality parameters such as noise power spectrum (NPS) and signal-to-noise ratio (SNR), which are also frequency-dependent, are employed for this investigation. The image detector uses 12 CCDs arranged in a 4 × 3 array to cover a field of 18 cm × 24 cm with a single x-ray exposure. Totally 18 sub-areas were chosen as the regions-of-interest (ROIs) for each full-field image to study position-dependent characteristics. Our experimental results indicate that the image quality at different positions of the full-field image exhibit slightly variance due to the characteristic diversity of the CCDs and due to the oblique angle of the ROIs to the x-ray source. The image seams caused by the physical gaps between adjacent CCDs do not increase the noise components significantly to the composite full-field image. The x-ray energy-dependence of NPS and SNR was also studied.

AB - Full-field digital mammography imaging systems have been investigated extensively. However, most investigations focus on the quality assessment of the entire image. In this article, we present the results of experimental measurements on the position-dependent image characteristics of a CCD array-based digital imaging system. Objective image quality parameters such as noise power spectrum (NPS) and signal-to-noise ratio (SNR), which are also frequency-dependent, are employed for this investigation. The image detector uses 12 CCDs arranged in a 4 × 3 array to cover a field of 18 cm × 24 cm with a single x-ray exposure. Totally 18 sub-areas were chosen as the regions-of-interest (ROIs) for each full-field image to study position-dependent characteristics. Our experimental results indicate that the image quality at different positions of the full-field image exhibit slightly variance due to the characteristic diversity of the CCDs and due to the oblique angle of the ROIs to the x-ray source. The image seams caused by the physical gaps between adjacent CCDs do not increase the noise components significantly to the composite full-field image. The x-ray energy-dependence of NPS and SNR was also studied.

KW - Digital radiography

KW - Full-field mammography systems

KW - Image quality

KW - Modulation transfer function

KW - Noise power spectra

KW - Signal-to-noise ratio

UR - http://www.scopus.com/inward/record.url?scp=0035556296&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=0035556296&partnerID=8YFLogxK

M3 - Article

VL - 9

SP - 101

EP - 111

JO - Journal of X-Ray Science and Technology

JF - Journal of X-Ray Science and Technology

SN - 0895-3996

IS - 3-4

ER -