Abstract

Background Some sensation to the breast returns after breast reconstruction, but recovery is variable and unpredictable. We primarily sought to assess the impact of different types of breast reconstruction [deep inferior epigastric artery perforator (DIEP) flaps versus implants] and radiation therapy on the return of sensation. Methods Thirty-seven patients who had unilateral or bilateral breast reconstruction via a DIEP flap or implant-based reconstruction, with or without radiation therapy (minimum follow-up, 18 months; range, 18-61 months) were studied. Of the 74 breasts, 27 had DIEP flaps, 29 had implants, and 18 were nonreconstructed. Eleven breasts with implants and 10 with DIEP flaps had had prereconstruction radiation therapy. The primary outcome was mean patient-perceived static and moving cutaneous pressure threshold in nine areas. We used univariate and multivariate analyses to assess what independent factors affected the return of sensation (significance, P < 0.05). Results Implants provided better static (P = 0.071) and moving sensation (P = 0.041) than did DIEP flaps. However, among irradiated breasts, skin over DIEP flaps had significantly better sensation than did that over implants (static, P = 0.019; moving, P = 0.028). Implant reconstructions with irradiated skin had significantly worse static (P = 0.002) and moving sensation (P = 0.014) than did nonirradiated implant reconstructions. Conclusions Without irradiation, skin overlying implants is associated with better sensation recovery than DIEP flap skin. However, with irradiation, DIEP flap skin had better sensation recovery than did skin over implants. Neurotization trended toward improvement in sensation in DIEP flaps. © 2013 Wiley Periodicals, Inc. Microsurgery 33:421-431, 2013.

Original languageEnglish (US)
Pages (from-to)421-431
Number of pages11
JournalMicrosurgery
Volume33
Issue number6
DOIs
StatePublished - Sep 2013

ASJC Scopus subject areas

  • Surgery

Fingerprint

Dive into the research topics of 'Pilot study of breast sensation after breast reconstruction: Evaluating the effects of radiation therapy and perforator flap neurotization on sensory recovery'. Together they form a unique fingerprint.

Cite this