Photothermal bundle measurement of phantoms and blood as a proof of concept for oxygenation saturation measurement

Yonat Milstein, Michal Tepper, Moshe Ben David, James A. Harrington, Israel Gannot

Research output: Contribution to journalLetter

Abstract

This study objective is to validate a method for the measurement of two compound phantoms as a proof of concept for oxygen saturation level measurement via a thermal imaging bundle. The method consists of a thermal imaging system and an algorithm which estimates the compound concentration according to temperature rise. A temperature rise is obtained by illuminating the tissue with a laser with different wavelengths in the NIR range and measured using a thermal camera. A coherent thermal imaging bundle was used for image transmittance for minimal invasive transendoscopic use. The algorithm's estimation ability was evaluated using agar phantoms of varying Methylene Blue and ICG ratios as well as blood samples The Methylene Blue ratio in each phantom was estimated and the calculated average RMS of the error was 9.38%, a satisfying value for this stage, verifying the algorithm's and bundle's suitability for the use in a minimal invasive system.

Original languageEnglish (US)
Pages (from-to)219-223
Number of pages5
JournalJournal of biophotonics
Volume4
Issue number4
DOIs
StatePublished - Apr 1 2011
Externally publishedYes

Fingerprint

Oxygenation
oxygenation
Infrared imaging
bundles
blood
Blood
Hot Temperature
Methylene Blue
methylene blue
saturation
Level measurement
Imaging systems
illuminating
Temperature
Agar
transmittance
Cameras
cameras
Tissue
Oxygen

Keywords

  • Coherent fiber bundle
  • Coherent optical systems
  • Infrared imaging
  • Photothermal spectroscopy
  • Thermal imaging
  • Tissue oxygenation

ASJC Scopus subject areas

  • Chemistry(all)
  • Materials Science(all)
  • Biochemistry, Genetics and Molecular Biology(all)
  • Engineering(all)
  • Physics and Astronomy(all)

Cite this

Photothermal bundle measurement of phantoms and blood as a proof of concept for oxygenation saturation measurement. / Milstein, Yonat; Tepper, Michal; David, Moshe Ben; Harrington, James A.; Gannot, Israel.

In: Journal of biophotonics, Vol. 4, No. 4, 01.04.2011, p. 219-223.

Research output: Contribution to journalLetter

Milstein, Yonat ; Tepper, Michal ; David, Moshe Ben ; Harrington, James A. ; Gannot, Israel. / Photothermal bundle measurement of phantoms and blood as a proof of concept for oxygenation saturation measurement. In: Journal of biophotonics. 2011 ; Vol. 4, No. 4. pp. 219-223.
@article{e9044957353347b1b77dfd068a9beb5f,
title = "Photothermal bundle measurement of phantoms and blood as a proof of concept for oxygenation saturation measurement",
abstract = "This study objective is to validate a method for the measurement of two compound phantoms as a proof of concept for oxygen saturation level measurement via a thermal imaging bundle. The method consists of a thermal imaging system and an algorithm which estimates the compound concentration according to temperature rise. A temperature rise is obtained by illuminating the tissue with a laser with different wavelengths in the NIR range and measured using a thermal camera. A coherent thermal imaging bundle was used for image transmittance for minimal invasive transendoscopic use. The algorithm's estimation ability was evaluated using agar phantoms of varying Methylene Blue and ICG ratios as well as blood samples The Methylene Blue ratio in each phantom was estimated and the calculated average RMS of the error was 9.38{\%}, a satisfying value for this stage, verifying the algorithm's and bundle's suitability for the use in a minimal invasive system.",
keywords = "Coherent fiber bundle, Coherent optical systems, Infrared imaging, Photothermal spectroscopy, Thermal imaging, Tissue oxygenation",
author = "Yonat Milstein and Michal Tepper and David, {Moshe Ben} and Harrington, {James A.} and Israel Gannot",
year = "2011",
month = "4",
day = "1",
doi = "10.1002/jbio.201000055",
language = "English (US)",
volume = "4",
pages = "219--223",
journal = "Journal of Biophotonics",
issn = "1864-063X",
publisher = "Wiley-VCH Verlag",
number = "4",

}

TY - JOUR

T1 - Photothermal bundle measurement of phantoms and blood as a proof of concept for oxygenation saturation measurement

AU - Milstein, Yonat

AU - Tepper, Michal

AU - David, Moshe Ben

AU - Harrington, James A.

AU - Gannot, Israel

PY - 2011/4/1

Y1 - 2011/4/1

N2 - This study objective is to validate a method for the measurement of two compound phantoms as a proof of concept for oxygen saturation level measurement via a thermal imaging bundle. The method consists of a thermal imaging system and an algorithm which estimates the compound concentration according to temperature rise. A temperature rise is obtained by illuminating the tissue with a laser with different wavelengths in the NIR range and measured using a thermal camera. A coherent thermal imaging bundle was used for image transmittance for minimal invasive transendoscopic use. The algorithm's estimation ability was evaluated using agar phantoms of varying Methylene Blue and ICG ratios as well as blood samples The Methylene Blue ratio in each phantom was estimated and the calculated average RMS of the error was 9.38%, a satisfying value for this stage, verifying the algorithm's and bundle's suitability for the use in a minimal invasive system.

AB - This study objective is to validate a method for the measurement of two compound phantoms as a proof of concept for oxygen saturation level measurement via a thermal imaging bundle. The method consists of a thermal imaging system and an algorithm which estimates the compound concentration according to temperature rise. A temperature rise is obtained by illuminating the tissue with a laser with different wavelengths in the NIR range and measured using a thermal camera. A coherent thermal imaging bundle was used for image transmittance for minimal invasive transendoscopic use. The algorithm's estimation ability was evaluated using agar phantoms of varying Methylene Blue and ICG ratios as well as blood samples The Methylene Blue ratio in each phantom was estimated and the calculated average RMS of the error was 9.38%, a satisfying value for this stage, verifying the algorithm's and bundle's suitability for the use in a minimal invasive system.

KW - Coherent fiber bundle

KW - Coherent optical systems

KW - Infrared imaging

KW - Photothermal spectroscopy

KW - Thermal imaging

KW - Tissue oxygenation

UR - http://www.scopus.com/inward/record.url?scp=79953096272&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=79953096272&partnerID=8YFLogxK

U2 - 10.1002/jbio.201000055

DO - 10.1002/jbio.201000055

M3 - Letter

C2 - 20635429

AN - SCOPUS:79953096272

VL - 4

SP - 219

EP - 223

JO - Journal of Biophotonics

JF - Journal of Biophotonics

SN - 1864-063X

IS - 4

ER -