Photoacoustic-based catheter tracking

Simulation, phantom, and in vivo studies

Alexis Cheng, Younsu Kim, Yuttana Itsarachaiyot, Haichong K. Zhang, Clifford Weiss, Russell H Taylor, Emad Boctor

Research output: Contribution to journalArticle

Abstract

Catheters are commonly used in many procedures and tracking and localizing them is critical to patient safety and surgical success. The standard of care for catheter tracking is with the use of fluoroscopy. Alternatives using conventional tracking technologies such as electromagnetic trackers have been previously explored. This work explores the use of an emerging imaging modality, photoacoustics, as a means for tracking. A piezoelectric (PZT) sensor is placed at the tip of the catheter, allowing it to receive the acoustic signals generated from photoacoustic markers due to the photoacoustic effect. The locations of these photoacoustic markers are determined by a stereo-camera and the received acoustic signals are converted into distances between the PZT element and the photoacoustic markers. The location of the PZT sensor can be uniquely determined following a multilateration process. This work validates this photoacoustic tracking method in phantom, simulation, and in vivo scenarios using metrics including reconstruction precision, relative accuracy, estimated accuracy, and leave-out accuracy. Submillimeter tracking results were achieved in phantom experiments. Simulation studies evaluated various physical parameters relating to the photoacoustic source and the PZT sensor. In vivo results showed feasibility for the eventual deployment of this technology.

Original languageEnglish (US)
Article number021223
JournalJournal of Medical Imaging
Volume5
Issue number2
DOIs
StatePublished - Apr 1 2018

Fingerprint

Catheters
Acoustics
Technology
Electromagnetic Phenomena
Fluoroscopy
Standard of Care
Patient Safety

Keywords

  • catheter tracking
  • image-guided procedures
  • interventional tool guidance
  • photoacoustics

ASJC Scopus subject areas

  • Radiology Nuclear Medicine and imaging

Cite this

Photoacoustic-based catheter tracking : Simulation, phantom, and in vivo studies. / Cheng, Alexis; Kim, Younsu; Itsarachaiyot, Yuttana; Zhang, Haichong K.; Weiss, Clifford; Taylor, Russell H; Boctor, Emad.

In: Journal of Medical Imaging, Vol. 5, No. 2, 021223, 01.04.2018.

Research output: Contribution to journalArticle

Cheng, Alexis ; Kim, Younsu ; Itsarachaiyot, Yuttana ; Zhang, Haichong K. ; Weiss, Clifford ; Taylor, Russell H ; Boctor, Emad. / Photoacoustic-based catheter tracking : Simulation, phantom, and in vivo studies. In: Journal of Medical Imaging. 2018 ; Vol. 5, No. 2.
@article{f7f0a7c8bb514c21a2bf1057fce9e14e,
title = "Photoacoustic-based catheter tracking: Simulation, phantom, and in vivo studies",
abstract = "Catheters are commonly used in many procedures and tracking and localizing them is critical to patient safety and surgical success. The standard of care for catheter tracking is with the use of fluoroscopy. Alternatives using conventional tracking technologies such as electromagnetic trackers have been previously explored. This work explores the use of an emerging imaging modality, photoacoustics, as a means for tracking. A piezoelectric (PZT) sensor is placed at the tip of the catheter, allowing it to receive the acoustic signals generated from photoacoustic markers due to the photoacoustic effect. The locations of these photoacoustic markers are determined by a stereo-camera and the received acoustic signals are converted into distances between the PZT element and the photoacoustic markers. The location of the PZT sensor can be uniquely determined following a multilateration process. This work validates this photoacoustic tracking method in phantom, simulation, and in vivo scenarios using metrics including reconstruction precision, relative accuracy, estimated accuracy, and leave-out accuracy. Submillimeter tracking results were achieved in phantom experiments. Simulation studies evaluated various physical parameters relating to the photoacoustic source and the PZT sensor. In vivo results showed feasibility for the eventual deployment of this technology.",
keywords = "catheter tracking, image-guided procedures, interventional tool guidance, photoacoustics",
author = "Alexis Cheng and Younsu Kim and Yuttana Itsarachaiyot and Zhang, {Haichong K.} and Clifford Weiss and Taylor, {Russell H} and Emad Boctor",
year = "2018",
month = "4",
day = "1",
doi = "10.1117/1.JMI.5.2.021223",
language = "English (US)",
volume = "5",
journal = "Journal of Medical Imaging",
issn = "0720-048X",
publisher = "Elsevier Ireland Ltd",
number = "2",

}

TY - JOUR

T1 - Photoacoustic-based catheter tracking

T2 - Simulation, phantom, and in vivo studies

AU - Cheng, Alexis

AU - Kim, Younsu

AU - Itsarachaiyot, Yuttana

AU - Zhang, Haichong K.

AU - Weiss, Clifford

AU - Taylor, Russell H

AU - Boctor, Emad

PY - 2018/4/1

Y1 - 2018/4/1

N2 - Catheters are commonly used in many procedures and tracking and localizing them is critical to patient safety and surgical success. The standard of care for catheter tracking is with the use of fluoroscopy. Alternatives using conventional tracking technologies such as electromagnetic trackers have been previously explored. This work explores the use of an emerging imaging modality, photoacoustics, as a means for tracking. A piezoelectric (PZT) sensor is placed at the tip of the catheter, allowing it to receive the acoustic signals generated from photoacoustic markers due to the photoacoustic effect. The locations of these photoacoustic markers are determined by a stereo-camera and the received acoustic signals are converted into distances between the PZT element and the photoacoustic markers. The location of the PZT sensor can be uniquely determined following a multilateration process. This work validates this photoacoustic tracking method in phantom, simulation, and in vivo scenarios using metrics including reconstruction precision, relative accuracy, estimated accuracy, and leave-out accuracy. Submillimeter tracking results were achieved in phantom experiments. Simulation studies evaluated various physical parameters relating to the photoacoustic source and the PZT sensor. In vivo results showed feasibility for the eventual deployment of this technology.

AB - Catheters are commonly used in many procedures and tracking and localizing them is critical to patient safety and surgical success. The standard of care for catheter tracking is with the use of fluoroscopy. Alternatives using conventional tracking technologies such as electromagnetic trackers have been previously explored. This work explores the use of an emerging imaging modality, photoacoustics, as a means for tracking. A piezoelectric (PZT) sensor is placed at the tip of the catheter, allowing it to receive the acoustic signals generated from photoacoustic markers due to the photoacoustic effect. The locations of these photoacoustic markers are determined by a stereo-camera and the received acoustic signals are converted into distances between the PZT element and the photoacoustic markers. The location of the PZT sensor can be uniquely determined following a multilateration process. This work validates this photoacoustic tracking method in phantom, simulation, and in vivo scenarios using metrics including reconstruction precision, relative accuracy, estimated accuracy, and leave-out accuracy. Submillimeter tracking results were achieved in phantom experiments. Simulation studies evaluated various physical parameters relating to the photoacoustic source and the PZT sensor. In vivo results showed feasibility for the eventual deployment of this technology.

KW - catheter tracking

KW - image-guided procedures

KW - interventional tool guidance

KW - photoacoustics

UR - http://www.scopus.com/inward/record.url?scp=85044791408&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=85044791408&partnerID=8YFLogxK

U2 - 10.1117/1.JMI.5.2.021223

DO - 10.1117/1.JMI.5.2.021223

M3 - Article

VL - 5

JO - Journal of Medical Imaging

JF - Journal of Medical Imaging

SN - 0720-048X

IS - 2

M1 - 021223

ER -