Performance of an automated polysomnography scoring system versus computer-assisted manual scoring

Atul Malhotra, Magdy Younes, Samuel T. Kuna, Ruth Benca, Clete A. Kushida, James Walsh, Alexandra Hanlon, Bethany Staley, Allan I. Pack, Grace W. Pien

Research output: Contribution to journalArticlepeer-review

68 Scopus citations

Abstract

Study Objectives: Manual scoring of polysomnograms (PSG) is labor intensive and has considerable variance between scorers. Automation of scoring could reduce cost and improve reproducibility. The purpose of this study was to compare a new automated scoring system (YST-Limited, Winnipeg, Canada) with computer-assisted manual scoring. Design: Technical assessment. Setting: Five academic medical centers. Participants: N/A. Interventions: N/A. Measurements and Results: Seventy PSG files were selected at University of Pennsylvania (Penn) and distributed to five US academic sleep centers. Two blinded technologists from each center scored each file. Automatic scoring was performed at Penn by a YST Limited technician using a laptop containing the software. Variables examined were sleep stages, arousals, and apnea-hypopnea index (AHI) using three methods of identifying hypopneas. Automatic scores were not edited and were compared to the average scores of the 10 technologists. Intraclass correlation coefficient (ICC) was obtained for the 70 pairs and compared to across-sites ICCs for manually scored results. ICCs for automatic versus manual scoring were > 0.8 for total sleep time, stage N2, and nonrapid eye movement arousals and > 0.9 for AHI scored by primary and secondary American Academy of Sleep Medicine criteria. ICCs for other variables were not as high but were comparable to the across-site ICCs for manually scored results. Conclusion: The automatic system yielded results that were similar to those obtained by experienced technologists. Very good ICCs were obtained for many primary PSG outcome measures. This automated scoring software, particularly if supplemented with manual editing, may increase laboratory efficiency and standardize PSG scoring results within and across sleep centers.

Original languageEnglish (US)
Pages (from-to)573-582
Number of pages10
JournalSleep
Volume36
Issue number4
DOIs
StatePublished - Apr 1 2013
Externally publishedYes

Keywords

  • Apnea-hypopnea index
  • Lung
  • Polysomnography
  • Reliability
  • Scoring
  • Sleep

ASJC Scopus subject areas

  • Clinical Neurology
  • Physiology (medical)

Fingerprint

Dive into the research topics of 'Performance of an automated polysomnography scoring system versus computer-assisted manual scoring'. Together they form a unique fingerprint.

Cite this