N2 - Purpose: To determine the type and distribution of ocular conditions cared for in a clinic dedicated to scleral devices and to report the clinical outcomes afforded by this approach. Methods: Fifty-one charts of patients fitted unilaterally or bilaterally with a scleral device (Prosthetic Replacement of the Ocular Surface Ecosystem - PROSE) in a two year period were retrospectively reviewed. Patient demographics, ocular diagnoses, associated systemic conditions, best corrected visual acuity (BCVA) before and after fitting, Visual Function Questionnaire score (VFQ-25), and ocular surface disease index (OSDI) score were collected. Results: All 51 patients were successfully wearing the PROSE device for a period of anywhere from weeks to years. The most common reasons for fitting were to relieve symptoms of moderate to severe dry eye syndrome ("DES", n=25), management of refractive problems ("refractive", n=23) with keratoconus being the most common (n=14), and to manage other anomalies ("other", n=3). Best corrected visual acuity (logMAR) improved with the wearing of the PROSE device for both the DES (17 letters) and the refractive group (10 letters), but not the "other" group. No serious complications were recorded for any of the patients. Conclusions: The PROSE device is a useful option not only for the management of ocular surface disease and optical imperfections, but also for other ophthalmic conditions. Moderate to severe dry eye was the most common anomaly managed, followed by eyes with irregular corneal astigmatism. DES and refractive patients experienced improvement in visual acuity with wearing of the PROSE device.
AB - Purpose: To determine the type and distribution of ocular conditions cared for in a clinic dedicated to scleral devices and to report the clinical outcomes afforded by this approach. Methods: Fifty-one charts of patients fitted unilaterally or bilaterally with a scleral device (Prosthetic Replacement of the Ocular Surface Ecosystem - PROSE) in a two year period were retrospectively reviewed. Patient demographics, ocular diagnoses, associated systemic conditions, best corrected visual acuity (BCVA) before and after fitting, Visual Function Questionnaire score (VFQ-25), and ocular surface disease index (OSDI) score were collected. Results: All 51 patients were successfully wearing the PROSE device for a period of anywhere from weeks to years. The most common reasons for fitting were to relieve symptoms of moderate to severe dry eye syndrome ("DES", n=25), management of refractive problems ("refractive", n=23) with keratoconus being the most common (n=14), and to manage other anomalies ("other", n=3). Best corrected visual acuity (logMAR) improved with the wearing of the PROSE device for both the DES (17 letters) and the refractive group (10 letters), but not the "other" group. No serious complications were recorded for any of the patients. Conclusions: The PROSE device is a useful option not only for the management of ocular surface disease and optical imperfections, but also for other ophthalmic conditions. Moderate to severe dry eye was the most common anomaly managed, followed by eyes with irregular corneal astigmatism. DES and refractive patients experienced improvement in visual acuity with wearing of the PROSE device.
KW - Dry eye
KW - Keratoconus
KW - Questionnaire
KW - Scleral contact lenses
KW - Visual function
UR - http://www.scopus.com/inward/record.url?scp=84879251444&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=84879251444&partnerID=8YFLogxK
U2 - 10.1016/j.clae.2013.02.004
DO - 10.1016/j.clae.2013.02.004
M3 - Article
C2 - 23499361
AN - SCOPUS:84879251444
SN - 1367-0484
VL - 36
SP - 159
EP - 163
JO - Contact Lens and Anterior Eye
JF - Contact Lens and Anterior Eye
IS - 4
ER -