Parameters for direct cortical electrical stimulation in the human: histopathologic confirmation

Barry Gordon, Ronald P Lesser, Naomi E. Rance, John Hart, William Webber, Sumio Uematsu, Robert S. Fisher

Research output: Contribution to journalArticle

Abstract

Safe parameters for electrical cortical stimulation in humans are difficult to estimate from the animal experimental literature. We therefore examined the light microscopic histology at a total of 11 sites of direct subdural electrical stimulation, taken as part of anterior temporal lobectomies in 3 patients. Stimulations had been done through 3.175 mm diameter electrodes, with 0.3 msec square wave pulses of alternating polarity at 50 pulses/sec. In 2 patients, one site each had been used as a common reference for stimulation, receiving over 251 stimulation trials, most of 2-5 sec duration, at currents of 12.5-15.0 mA, 1 day prior to resection. The maximum charge per phase was 4.0-4.4 μC; the maximum charge density was 52-57 μC per geometric cm2 per pulse at the electrode surfaces. Comparison of hematoxylin and eosin, periodic acid-Schiff, and cresyl violet-stained material from the electrode sites with that from other regions did not show any histologic abnormalities attributable to the electrical stimulation. The relatively brief and intermittent periods utilized for human stimulation testing do not appear to cause strcutural damage at the light microscopic level at charge densities that exceed the threshold for damage established in animal studies with more continuous, chronic stimulation schedules.

Original languageEnglish (US)
Pages (from-to)371-377
Number of pages7
JournalElectroencephalography and Clinical Neurophysiology
Volume75
Issue number5
DOIs
StatePublished - 1990

Fingerprint

Electric Stimulation
Electrodes
Anterior Temporal Lobectomy
Light
Periodic Acid
Hematoxylin
Eosine Yellowish-(YS)
Histology
Appointments and Schedules
cresyl violet

Keywords

  • (Human)
  • Electrical cortical stimulation
  • Histopathology
  • Safety
  • Subdural arrays

ASJC Scopus subject areas

  • Clinical Neurology
  • Neuroscience(all)

Cite this

Parameters for direct cortical electrical stimulation in the human : histopathologic confirmation. / Gordon, Barry; Lesser, Ronald P; Rance, Naomi E.; Hart, John; Webber, William; Uematsu, Sumio; Fisher, Robert S.

In: Electroencephalography and Clinical Neurophysiology, Vol. 75, No. 5, 1990, p. 371-377.

Research output: Contribution to journalArticle

@article{d36438f40aec41fa8690422cd523a04e,
title = "Parameters for direct cortical electrical stimulation in the human: histopathologic confirmation",
abstract = "Safe parameters for electrical cortical stimulation in humans are difficult to estimate from the animal experimental literature. We therefore examined the light microscopic histology at a total of 11 sites of direct subdural electrical stimulation, taken as part of anterior temporal lobectomies in 3 patients. Stimulations had been done through 3.175 mm diameter electrodes, with 0.3 msec square wave pulses of alternating polarity at 50 pulses/sec. In 2 patients, one site each had been used as a common reference for stimulation, receiving over 251 stimulation trials, most of 2-5 sec duration, at currents of 12.5-15.0 mA, 1 day prior to resection. The maximum charge per phase was 4.0-4.4 μC; the maximum charge density was 52-57 μC per geometric cm2 per pulse at the electrode surfaces. Comparison of hematoxylin and eosin, periodic acid-Schiff, and cresyl violet-stained material from the electrode sites with that from other regions did not show any histologic abnormalities attributable to the electrical stimulation. The relatively brief and intermittent periods utilized for human stimulation testing do not appear to cause strcutural damage at the light microscopic level at charge densities that exceed the threshold for damage established in animal studies with more continuous, chronic stimulation schedules.",
keywords = "(Human), Electrical cortical stimulation, Histopathology, Safety, Subdural arrays",
author = "Barry Gordon and Lesser, {Ronald P} and Rance, {Naomi E.} and John Hart and William Webber and Sumio Uematsu and Fisher, {Robert S.}",
year = "1990",
doi = "10.1016/0013-4694(90)90082-U",
language = "English (US)",
volume = "75",
pages = "371--377",
journal = "Electroencephalography and Clinical Neurophysiology",
issn = "0013-4694",
publisher = "Elsevier BV",
number = "5",

}

TY - JOUR

T1 - Parameters for direct cortical electrical stimulation in the human

T2 - histopathologic confirmation

AU - Gordon, Barry

AU - Lesser, Ronald P

AU - Rance, Naomi E.

AU - Hart, John

AU - Webber, William

AU - Uematsu, Sumio

AU - Fisher, Robert S.

PY - 1990

Y1 - 1990

N2 - Safe parameters for electrical cortical stimulation in humans are difficult to estimate from the animal experimental literature. We therefore examined the light microscopic histology at a total of 11 sites of direct subdural electrical stimulation, taken as part of anterior temporal lobectomies in 3 patients. Stimulations had been done through 3.175 mm diameter electrodes, with 0.3 msec square wave pulses of alternating polarity at 50 pulses/sec. In 2 patients, one site each had been used as a common reference for stimulation, receiving over 251 stimulation trials, most of 2-5 sec duration, at currents of 12.5-15.0 mA, 1 day prior to resection. The maximum charge per phase was 4.0-4.4 μC; the maximum charge density was 52-57 μC per geometric cm2 per pulse at the electrode surfaces. Comparison of hematoxylin and eosin, periodic acid-Schiff, and cresyl violet-stained material from the electrode sites with that from other regions did not show any histologic abnormalities attributable to the electrical stimulation. The relatively brief and intermittent periods utilized for human stimulation testing do not appear to cause strcutural damage at the light microscopic level at charge densities that exceed the threshold for damage established in animal studies with more continuous, chronic stimulation schedules.

AB - Safe parameters for electrical cortical stimulation in humans are difficult to estimate from the animal experimental literature. We therefore examined the light microscopic histology at a total of 11 sites of direct subdural electrical stimulation, taken as part of anterior temporal lobectomies in 3 patients. Stimulations had been done through 3.175 mm diameter electrodes, with 0.3 msec square wave pulses of alternating polarity at 50 pulses/sec. In 2 patients, one site each had been used as a common reference for stimulation, receiving over 251 stimulation trials, most of 2-5 sec duration, at currents of 12.5-15.0 mA, 1 day prior to resection. The maximum charge per phase was 4.0-4.4 μC; the maximum charge density was 52-57 μC per geometric cm2 per pulse at the electrode surfaces. Comparison of hematoxylin and eosin, periodic acid-Schiff, and cresyl violet-stained material from the electrode sites with that from other regions did not show any histologic abnormalities attributable to the electrical stimulation. The relatively brief and intermittent periods utilized for human stimulation testing do not appear to cause strcutural damage at the light microscopic level at charge densities that exceed the threshold for damage established in animal studies with more continuous, chronic stimulation schedules.

KW - (Human)

KW - Electrical cortical stimulation

KW - Histopathology

KW - Safety

KW - Subdural arrays

UR - http://www.scopus.com/inward/record.url?scp=0025254540&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=0025254540&partnerID=8YFLogxK

U2 - 10.1016/0013-4694(90)90082-U

DO - 10.1016/0013-4694(90)90082-U

M3 - Article

C2 - 1692272

AN - SCOPUS:0025254540

VL - 75

SP - 371

EP - 377

JO - Electroencephalography and Clinical Neurophysiology

JF - Electroencephalography and Clinical Neurophysiology

SN - 0013-4694

IS - 5

ER -