Optokinetic afternystagmus in humans: Normal values of amplitude, time constant, and asymmetry

M. A J Tijssen, T. C. Hain, C. S M Straathof, David Samuel Zee

Research output: Contribution to journalArticle

Abstract

It has been suggested that the appearance of directional asymmetry and/or a reduced time constant of optokinetic afternystagmus (OKAN) might be a clinical index of vestibular imbalance. However, we do not know the limits for OKAN parameters in normal humans. Accordingly, we studied OKAN in 30 normal subjects using a 'sampling' method, in which a number of values of OKAN are obtained by turning out the lights periodically during optokinetic stimulation. We found that the initial velocity of OKAN has a large intrasubject variability. Accordingly, if precision is desired so as to obtain 95% confidence that the measured mean of the initial velocity of OKAN is within 25% of the true mean in an individual subject, at least eight measurements of the initial OKAN velocity must be taken. When 12 measurements are made, all subjects had a minimum value of 5°/s initial OKAN, and there was little directional asymmetry (mean of -0.47°/s ± 3.13°/s). The intrasubject variability of the time constant of OKAN was similar to the variability of initial OKAN velocity. However, because it is not possible to obtain repeated measures of the time constant in a short period of time, the time constant of OKAN is less likely to be useful in clinical testing.

Original languageEnglish (US)
Pages (from-to)741-746
Number of pages6
JournalAnnals of Otology, Rhinology and Laryngology
Volume98
Issue number9
StatePublished - 1989

Fingerprint

Reference Values
Light

ASJC Scopus subject areas

  • Otorhinolaryngology

Cite this

Optokinetic afternystagmus in humans : Normal values of amplitude, time constant, and asymmetry. / Tijssen, M. A J; Hain, T. C.; Straathof, C. S M; Zee, David Samuel.

In: Annals of Otology, Rhinology and Laryngology, Vol. 98, No. 9, 1989, p. 741-746.

Research output: Contribution to journalArticle

@article{ab006b63171a4ba3a3ebd777950b3453,
title = "Optokinetic afternystagmus in humans: Normal values of amplitude, time constant, and asymmetry",
abstract = "It has been suggested that the appearance of directional asymmetry and/or a reduced time constant of optokinetic afternystagmus (OKAN) might be a clinical index of vestibular imbalance. However, we do not know the limits for OKAN parameters in normal humans. Accordingly, we studied OKAN in 30 normal subjects using a 'sampling' method, in which a number of values of OKAN are obtained by turning out the lights periodically during optokinetic stimulation. We found that the initial velocity of OKAN has a large intrasubject variability. Accordingly, if precision is desired so as to obtain 95{\%} confidence that the measured mean of the initial velocity of OKAN is within 25{\%} of the true mean in an individual subject, at least eight measurements of the initial OKAN velocity must be taken. When 12 measurements are made, all subjects had a minimum value of 5°/s initial OKAN, and there was little directional asymmetry (mean of -0.47°/s ± 3.13°/s). The intrasubject variability of the time constant of OKAN was similar to the variability of initial OKAN velocity. However, because it is not possible to obtain repeated measures of the time constant in a short period of time, the time constant of OKAN is less likely to be useful in clinical testing.",
author = "Tijssen, {M. A J} and Hain, {T. C.} and Straathof, {C. S M} and Zee, {David Samuel}",
year = "1989",
language = "English (US)",
volume = "98",
pages = "741--746",
journal = "Annals of Otology, Rhinology and Laryngology",
issn = "0003-4894",
publisher = "Annals Publishing Company",
number = "9",

}

TY - JOUR

T1 - Optokinetic afternystagmus in humans

T2 - Normal values of amplitude, time constant, and asymmetry

AU - Tijssen, M. A J

AU - Hain, T. C.

AU - Straathof, C. S M

AU - Zee, David Samuel

PY - 1989

Y1 - 1989

N2 - It has been suggested that the appearance of directional asymmetry and/or a reduced time constant of optokinetic afternystagmus (OKAN) might be a clinical index of vestibular imbalance. However, we do not know the limits for OKAN parameters in normal humans. Accordingly, we studied OKAN in 30 normal subjects using a 'sampling' method, in which a number of values of OKAN are obtained by turning out the lights periodically during optokinetic stimulation. We found that the initial velocity of OKAN has a large intrasubject variability. Accordingly, if precision is desired so as to obtain 95% confidence that the measured mean of the initial velocity of OKAN is within 25% of the true mean in an individual subject, at least eight measurements of the initial OKAN velocity must be taken. When 12 measurements are made, all subjects had a minimum value of 5°/s initial OKAN, and there was little directional asymmetry (mean of -0.47°/s ± 3.13°/s). The intrasubject variability of the time constant of OKAN was similar to the variability of initial OKAN velocity. However, because it is not possible to obtain repeated measures of the time constant in a short period of time, the time constant of OKAN is less likely to be useful in clinical testing.

AB - It has been suggested that the appearance of directional asymmetry and/or a reduced time constant of optokinetic afternystagmus (OKAN) might be a clinical index of vestibular imbalance. However, we do not know the limits for OKAN parameters in normal humans. Accordingly, we studied OKAN in 30 normal subjects using a 'sampling' method, in which a number of values of OKAN are obtained by turning out the lights periodically during optokinetic stimulation. We found that the initial velocity of OKAN has a large intrasubject variability. Accordingly, if precision is desired so as to obtain 95% confidence that the measured mean of the initial velocity of OKAN is within 25% of the true mean in an individual subject, at least eight measurements of the initial OKAN velocity must be taken. When 12 measurements are made, all subjects had a minimum value of 5°/s initial OKAN, and there was little directional asymmetry (mean of -0.47°/s ± 3.13°/s). The intrasubject variability of the time constant of OKAN was similar to the variability of initial OKAN velocity. However, because it is not possible to obtain repeated measures of the time constant in a short period of time, the time constant of OKAN is less likely to be useful in clinical testing.

UR - http://www.scopus.com/inward/record.url?scp=0024461663&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=0024461663&partnerID=8YFLogxK

M3 - Article

C2 - 2782808

AN - SCOPUS:0024461663

VL - 98

SP - 741

EP - 746

JO - Annals of Otology, Rhinology and Laryngology

JF - Annals of Otology, Rhinology and Laryngology

SN - 0003-4894

IS - 9

ER -