Optimum flip-angles for exciting NMR with uncertain T1 values

Paul A Bottomley, R. Ouwerkerk

Research output: Contribution to journalArticle

Abstract

T1 is often ill-determined. This means that an Ernst angle excitation often cannot be precisely defined for the simple pulse and acquire experiment. Here, published 31P T1 values of metabolites in human muscle, liver, heart, and brain are archived, some new data on heart and brain added, and overall confidence intervals determined. Strategies for setting the flip- angle based on the confidence intervals are examined, and an optimum flip- angle derived which minimizes the signal loss relative to what could have been realized if T1 were precisely known. With such optimized pulses, signal loss can be limited to ≤14% for up to a 10-fold variation in T1, with TR ≤ T1. The effect that an uncertainty in T1 by a factor of two has on the saturation corrected signal is limited to ≤20% in the optimum flip-angle experiment. Adiabatic B1-independent rotation phase-cycled (BIRP) excitation pulses are ideal as optimum flip-angle pulses as they can be prescribed without calibration.

Original languageEnglish (US)
Pages (from-to)137-141
Number of pages5
JournalMagnetic Resonance in Medicine
Volume32
Issue number1
DOIs
StatePublished - 1994

Fingerprint

Confidence Intervals
Brain
Calibration
Uncertainty
Pulse
Myocardium
Liver

ASJC Scopus subject areas

  • Radiology Nuclear Medicine and imaging
  • Radiological and Ultrasound Technology

Cite this

Optimum flip-angles for exciting NMR with uncertain T1 values. / Bottomley, Paul A; Ouwerkerk, R.

In: Magnetic Resonance in Medicine, Vol. 32, No. 1, 1994, p. 137-141.

Research output: Contribution to journalArticle

@article{b18d5f5af74f4b09a9a15bf21b71fe4f,
title = "Optimum flip-angles for exciting NMR with uncertain T1 values",
abstract = "T1 is often ill-determined. This means that an Ernst angle excitation often cannot be precisely defined for the simple pulse and acquire experiment. Here, published 31P T1 values of metabolites in human muscle, liver, heart, and brain are archived, some new data on heart and brain added, and overall confidence intervals determined. Strategies for setting the flip- angle based on the confidence intervals are examined, and an optimum flip- angle derived which minimizes the signal loss relative to what could have been realized if T1 were precisely known. With such optimized pulses, signal loss can be limited to ≤14{\%} for up to a 10-fold variation in T1, with TR ≤ T1. The effect that an uncertainty in T1 by a factor of two has on the saturation corrected signal is limited to ≤20{\%} in the optimum flip-angle experiment. Adiabatic B1-independent rotation phase-cycled (BIRP) excitation pulses are ideal as optimum flip-angle pulses as they can be prescribed without calibration.",
author = "Bottomley, {Paul A} and R. Ouwerkerk",
year = "1994",
doi = "10.1002/mrm.1910320120",
language = "English (US)",
volume = "32",
pages = "137--141",
journal = "Magnetic Resonance in Medicine",
issn = "0740-3194",
publisher = "John Wiley and Sons Inc.",
number = "1",

}

TY - JOUR

T1 - Optimum flip-angles for exciting NMR with uncertain T1 values

AU - Bottomley, Paul A

AU - Ouwerkerk, R.

PY - 1994

Y1 - 1994

N2 - T1 is often ill-determined. This means that an Ernst angle excitation often cannot be precisely defined for the simple pulse and acquire experiment. Here, published 31P T1 values of metabolites in human muscle, liver, heart, and brain are archived, some new data on heart and brain added, and overall confidence intervals determined. Strategies for setting the flip- angle based on the confidence intervals are examined, and an optimum flip- angle derived which minimizes the signal loss relative to what could have been realized if T1 were precisely known. With such optimized pulses, signal loss can be limited to ≤14% for up to a 10-fold variation in T1, with TR ≤ T1. The effect that an uncertainty in T1 by a factor of two has on the saturation corrected signal is limited to ≤20% in the optimum flip-angle experiment. Adiabatic B1-independent rotation phase-cycled (BIRP) excitation pulses are ideal as optimum flip-angle pulses as they can be prescribed without calibration.

AB - T1 is often ill-determined. This means that an Ernst angle excitation often cannot be precisely defined for the simple pulse and acquire experiment. Here, published 31P T1 values of metabolites in human muscle, liver, heart, and brain are archived, some new data on heart and brain added, and overall confidence intervals determined. Strategies for setting the flip- angle based on the confidence intervals are examined, and an optimum flip- angle derived which minimizes the signal loss relative to what could have been realized if T1 were precisely known. With such optimized pulses, signal loss can be limited to ≤14% for up to a 10-fold variation in T1, with TR ≤ T1. The effect that an uncertainty in T1 by a factor of two has on the saturation corrected signal is limited to ≤20% in the optimum flip-angle experiment. Adiabatic B1-independent rotation phase-cycled (BIRP) excitation pulses are ideal as optimum flip-angle pulses as they can be prescribed without calibration.

UR - http://www.scopus.com/inward/record.url?scp=0028365711&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=0028365711&partnerID=8YFLogxK

U2 - 10.1002/mrm.1910320120

DO - 10.1002/mrm.1910320120

M3 - Article

C2 - 8084230

AN - SCOPUS:0028365711

VL - 32

SP - 137

EP - 141

JO - Magnetic Resonance in Medicine

JF - Magnetic Resonance in Medicine

SN - 0740-3194

IS - 1