Optimization of fast acquisition methods for whole-brain relative cerebral blood volume (rCBV) mapping with susceptibility contrast agents

L. Hou, Y. Yang, Venkata Mattay, J. A. Frank, J. H. Duyn

Research output: Contribution to journalArticle

Abstract

Fast gradient-echo magnetic resonance scan techniques with spiral and rectilinear (echoplanar) k-space trajectories were optimized to perform bolus-tracking studies of human brain. Cerebral hemodynamics were studied with full brain coverage, a spatial resolution of 4 mm, and a temporal resolution of 2 seconds. The sensitivity of the techniques to detect image signal-intensity changes during the first pass of the contrast agent was studied at a range of TEs using dedicated experiments. For single-shot versions of spiral scanning and echoplanar imaging techniques with a 0.1- mmol/kg injection of gadolinium diethylenetriamine pentaacetic acid using a mechanical injector at 10 mL/sec under 1.5 T, the maximum sensitivity was obtained at TEs between 35 and 45 msec. At TEs less than 35 msec, signal- intensity artifacts were observed in the images. Analysis of the point- spread function revealed that susceptibility changes induced by the contrast agent can result in signal shifts to neighboring voxels. These artifacts are attributed to susceptibility-related signal changes during the acquisition window.

Original languageEnglish (US)
Pages (from-to)233-239
Number of pages7
JournalJournal of Magnetic Resonance Imaging
Volume9
Issue number2
DOIs
StatePublished - 1999
Externally publishedYes

Fingerprint

Artifacts
Contrast Media
Echo-Planar Imaging
Pentetic Acid
Gadolinium
Brain
Magnetic Resonance Spectroscopy
Hemodynamics
Injections
Cerebral Blood Volume

Keywords

  • Bolus tracking (BT)
  • CBV
  • EPI
  • Perfusion
  • Spiral imaging

ASJC Scopus subject areas

  • Radiology Nuclear Medicine and imaging
  • Radiological and Ultrasound Technology

Cite this

Optimization of fast acquisition methods for whole-brain relative cerebral blood volume (rCBV) mapping with susceptibility contrast agents. / Hou, L.; Yang, Y.; Mattay, Venkata; Frank, J. A.; Duyn, J. H.

In: Journal of Magnetic Resonance Imaging, Vol. 9, No. 2, 1999, p. 233-239.

Research output: Contribution to journalArticle

@article{2898a84034e34182a149aaaeab8baf0f,
title = "Optimization of fast acquisition methods for whole-brain relative cerebral blood volume (rCBV) mapping with susceptibility contrast agents",
abstract = "Fast gradient-echo magnetic resonance scan techniques with spiral and rectilinear (echoplanar) k-space trajectories were optimized to perform bolus-tracking studies of human brain. Cerebral hemodynamics were studied with full brain coverage, a spatial resolution of 4 mm, and a temporal resolution of 2 seconds. The sensitivity of the techniques to detect image signal-intensity changes during the first pass of the contrast agent was studied at a range of TEs using dedicated experiments. For single-shot versions of spiral scanning and echoplanar imaging techniques with a 0.1- mmol/kg injection of gadolinium diethylenetriamine pentaacetic acid using a mechanical injector at 10 mL/sec under 1.5 T, the maximum sensitivity was obtained at TEs between 35 and 45 msec. At TEs less than 35 msec, signal- intensity artifacts were observed in the images. Analysis of the point- spread function revealed that susceptibility changes induced by the contrast agent can result in signal shifts to neighboring voxels. These artifacts are attributed to susceptibility-related signal changes during the acquisition window.",
keywords = "Bolus tracking (BT), CBV, EPI, Perfusion, Spiral imaging",
author = "L. Hou and Y. Yang and Venkata Mattay and Frank, {J. A.} and Duyn, {J. H.}",
year = "1999",
doi = "10.1002/(SICI)1522-2586(199902)9:2<233::AID-JMRI13>3.0.CO;2-V",
language = "English (US)",
volume = "9",
pages = "233--239",
journal = "Journal of Magnetic Resonance Imaging",
issn = "1053-1807",
publisher = "John Wiley and Sons Inc.",
number = "2",

}

TY - JOUR

T1 - Optimization of fast acquisition methods for whole-brain relative cerebral blood volume (rCBV) mapping with susceptibility contrast agents

AU - Hou, L.

AU - Yang, Y.

AU - Mattay, Venkata

AU - Frank, J. A.

AU - Duyn, J. H.

PY - 1999

Y1 - 1999

N2 - Fast gradient-echo magnetic resonance scan techniques with spiral and rectilinear (echoplanar) k-space trajectories were optimized to perform bolus-tracking studies of human brain. Cerebral hemodynamics were studied with full brain coverage, a spatial resolution of 4 mm, and a temporal resolution of 2 seconds. The sensitivity of the techniques to detect image signal-intensity changes during the first pass of the contrast agent was studied at a range of TEs using dedicated experiments. For single-shot versions of spiral scanning and echoplanar imaging techniques with a 0.1- mmol/kg injection of gadolinium diethylenetriamine pentaacetic acid using a mechanical injector at 10 mL/sec under 1.5 T, the maximum sensitivity was obtained at TEs between 35 and 45 msec. At TEs less than 35 msec, signal- intensity artifacts were observed in the images. Analysis of the point- spread function revealed that susceptibility changes induced by the contrast agent can result in signal shifts to neighboring voxels. These artifacts are attributed to susceptibility-related signal changes during the acquisition window.

AB - Fast gradient-echo magnetic resonance scan techniques with spiral and rectilinear (echoplanar) k-space trajectories were optimized to perform bolus-tracking studies of human brain. Cerebral hemodynamics were studied with full brain coverage, a spatial resolution of 4 mm, and a temporal resolution of 2 seconds. The sensitivity of the techniques to detect image signal-intensity changes during the first pass of the contrast agent was studied at a range of TEs using dedicated experiments. For single-shot versions of spiral scanning and echoplanar imaging techniques with a 0.1- mmol/kg injection of gadolinium diethylenetriamine pentaacetic acid using a mechanical injector at 10 mL/sec under 1.5 T, the maximum sensitivity was obtained at TEs between 35 and 45 msec. At TEs less than 35 msec, signal- intensity artifacts were observed in the images. Analysis of the point- spread function revealed that susceptibility changes induced by the contrast agent can result in signal shifts to neighboring voxels. These artifacts are attributed to susceptibility-related signal changes during the acquisition window.

KW - Bolus tracking (BT)

KW - CBV

KW - EPI

KW - Perfusion

KW - Spiral imaging

UR - http://www.scopus.com/inward/record.url?scp=0032968029&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=0032968029&partnerID=8YFLogxK

U2 - 10.1002/(SICI)1522-2586(199902)9:2<233::AID-JMRI13>3.0.CO;2-V

DO - 10.1002/(SICI)1522-2586(199902)9:2<233::AID-JMRI13>3.0.CO;2-V

M3 - Article

VL - 9

SP - 233

EP - 239

JO - Journal of Magnetic Resonance Imaging

JF - Journal of Magnetic Resonance Imaging

SN - 1053-1807

IS - 2

ER -