Optimal contrast concentration for CT-guided epidural steroid injections

Peter G. Kranz, M. Abbott, D. Abbott, J. K. Hoang

Research output: Contribution to journalArticle

Abstract

BACKGROUND AND PURPOSE: Contrast is used in CT-guided epidural steroid injections to ensure proper needle placement. Once injected, undiluted contrast often obscures the needle, hindering subsequent repositioning. The purpose of this investigation was to establish the optimal contrast dilution for CT-guided epidural steroid injections. MATERIALS AND METHODS: This investigation consisted of an initial phantom study, followed by a prospective, randomized, singlecenter trial assessing a range of contrast dilutions. In the phantom study, a phantom housing a chamber containing a 22-gauge needle and various dilutions of contrast was scanned, and images were evaluated for needle visibility. On the basis of these results, concentrations of 66, 100, 133, and 150 mg/mL iodine were selected for evaluation in a clinical study. Patients presenting for CT-guided epidural steroid injections were randomly assigned to a contrast dilution, and images from the procedure were evaluated by 2 readers blinded to the contrast assignment. Needle visibility was scored by use of a 5-point scale. RESULTS: In the phantom study, the needle was not visible at contrast concentrations of ≥133 mg/mL. In the clinical study, needle visibility was strongly associated with contrast concentration (P < .0001). Significant improvements in visibility were found in 66 mg/mL and 100 mg/mL compared with higher iodine concentrations; no difference was found comparing 66 mg/mL with 100 mg/mL iodine. Neither injection location (cervical versus lumbar) nor technique (interlaminar versus transforaminal) influenced visibility scores. CONCLUSIONS: For CT-guided epidural steroid injections, the optimal contrast concentration is 66-100 mg/mL iodine. Because these concentrations are not commercially available, proceduralists must dilute their contrast for such procedures.

Original languageEnglish (US)
Pages (from-to)191-195
Number of pages5
JournalAmerican Journal of Neuroradiology
Volume35
Issue number1
DOIs
StatePublished - Jan 1 2014
Externally publishedYes

Fingerprint

Epidural Injections
Needles
Steroids
Iodine
Injections

ASJC Scopus subject areas

  • Radiology Nuclear Medicine and imaging
  • Clinical Neurology

Cite this

Optimal contrast concentration for CT-guided epidural steroid injections. / Kranz, Peter G.; Abbott, M.; Abbott, D.; Hoang, J. K.

In: American Journal of Neuroradiology, Vol. 35, No. 1, 01.01.2014, p. 191-195.

Research output: Contribution to journalArticle

Kranz, Peter G. ; Abbott, M. ; Abbott, D. ; Hoang, J. K. / Optimal contrast concentration for CT-guided epidural steroid injections. In: American Journal of Neuroradiology. 2014 ; Vol. 35, No. 1. pp. 191-195.
@article{5f3418d06b294b2294523cc3b3b89bfa,
title = "Optimal contrast concentration for CT-guided epidural steroid injections",
abstract = "BACKGROUND AND PURPOSE: Contrast is used in CT-guided epidural steroid injections to ensure proper needle placement. Once injected, undiluted contrast often obscures the needle, hindering subsequent repositioning. The purpose of this investigation was to establish the optimal contrast dilution for CT-guided epidural steroid injections. MATERIALS AND METHODS: This investigation consisted of an initial phantom study, followed by a prospective, randomized, singlecenter trial assessing a range of contrast dilutions. In the phantom study, a phantom housing a chamber containing a 22-gauge needle and various dilutions of contrast was scanned, and images were evaluated for needle visibility. On the basis of these results, concentrations of 66, 100, 133, and 150 mg/mL iodine were selected for evaluation in a clinical study. Patients presenting for CT-guided epidural steroid injections were randomly assigned to a contrast dilution, and images from the procedure were evaluated by 2 readers blinded to the contrast assignment. Needle visibility was scored by use of a 5-point scale. RESULTS: In the phantom study, the needle was not visible at contrast concentrations of ≥133 mg/mL. In the clinical study, needle visibility was strongly associated with contrast concentration (P < .0001). Significant improvements in visibility were found in 66 mg/mL and 100 mg/mL compared with higher iodine concentrations; no difference was found comparing 66 mg/mL with 100 mg/mL iodine. Neither injection location (cervical versus lumbar) nor technique (interlaminar versus transforaminal) influenced visibility scores. CONCLUSIONS: For CT-guided epidural steroid injections, the optimal contrast concentration is 66-100 mg/mL iodine. Because these concentrations are not commercially available, proceduralists must dilute their contrast for such procedures.",
author = "Kranz, {Peter G.} and M. Abbott and D. Abbott and Hoang, {J. K.}",
year = "2014",
month = "1",
day = "1",
doi = "10.3174/ajnr.A3626",
language = "English (US)",
volume = "35",
pages = "191--195",
journal = "American Journal of Neuroradiology",
issn = "0195-6108",
publisher = "American Society of Neuroradiology",
number = "1",

}

TY - JOUR

T1 - Optimal contrast concentration for CT-guided epidural steroid injections

AU - Kranz, Peter G.

AU - Abbott, M.

AU - Abbott, D.

AU - Hoang, J. K.

PY - 2014/1/1

Y1 - 2014/1/1

N2 - BACKGROUND AND PURPOSE: Contrast is used in CT-guided epidural steroid injections to ensure proper needle placement. Once injected, undiluted contrast often obscures the needle, hindering subsequent repositioning. The purpose of this investigation was to establish the optimal contrast dilution for CT-guided epidural steroid injections. MATERIALS AND METHODS: This investigation consisted of an initial phantom study, followed by a prospective, randomized, singlecenter trial assessing a range of contrast dilutions. In the phantom study, a phantom housing a chamber containing a 22-gauge needle and various dilutions of contrast was scanned, and images were evaluated for needle visibility. On the basis of these results, concentrations of 66, 100, 133, and 150 mg/mL iodine were selected for evaluation in a clinical study. Patients presenting for CT-guided epidural steroid injections were randomly assigned to a contrast dilution, and images from the procedure were evaluated by 2 readers blinded to the contrast assignment. Needle visibility was scored by use of a 5-point scale. RESULTS: In the phantom study, the needle was not visible at contrast concentrations of ≥133 mg/mL. In the clinical study, needle visibility was strongly associated with contrast concentration (P < .0001). Significant improvements in visibility were found in 66 mg/mL and 100 mg/mL compared with higher iodine concentrations; no difference was found comparing 66 mg/mL with 100 mg/mL iodine. Neither injection location (cervical versus lumbar) nor technique (interlaminar versus transforaminal) influenced visibility scores. CONCLUSIONS: For CT-guided epidural steroid injections, the optimal contrast concentration is 66-100 mg/mL iodine. Because these concentrations are not commercially available, proceduralists must dilute their contrast for such procedures.

AB - BACKGROUND AND PURPOSE: Contrast is used in CT-guided epidural steroid injections to ensure proper needle placement. Once injected, undiluted contrast often obscures the needle, hindering subsequent repositioning. The purpose of this investigation was to establish the optimal contrast dilution for CT-guided epidural steroid injections. MATERIALS AND METHODS: This investigation consisted of an initial phantom study, followed by a prospective, randomized, singlecenter trial assessing a range of contrast dilutions. In the phantom study, a phantom housing a chamber containing a 22-gauge needle and various dilutions of contrast was scanned, and images were evaluated for needle visibility. On the basis of these results, concentrations of 66, 100, 133, and 150 mg/mL iodine were selected for evaluation in a clinical study. Patients presenting for CT-guided epidural steroid injections were randomly assigned to a contrast dilution, and images from the procedure were evaluated by 2 readers blinded to the contrast assignment. Needle visibility was scored by use of a 5-point scale. RESULTS: In the phantom study, the needle was not visible at contrast concentrations of ≥133 mg/mL. In the clinical study, needle visibility was strongly associated with contrast concentration (P < .0001). Significant improvements in visibility were found in 66 mg/mL and 100 mg/mL compared with higher iodine concentrations; no difference was found comparing 66 mg/mL with 100 mg/mL iodine. Neither injection location (cervical versus lumbar) nor technique (interlaminar versus transforaminal) influenced visibility scores. CONCLUSIONS: For CT-guided epidural steroid injections, the optimal contrast concentration is 66-100 mg/mL iodine. Because these concentrations are not commercially available, proceduralists must dilute their contrast for such procedures.

UR - http://www.scopus.com/inward/record.url?scp=84892731078&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=84892731078&partnerID=8YFLogxK

U2 - 10.3174/ajnr.A3626

DO - 10.3174/ajnr.A3626

M3 - Article

C2 - 23886739

AN - SCOPUS:84892731078

VL - 35

SP - 191

EP - 195

JO - American Journal of Neuroradiology

JF - American Journal of Neuroradiology

SN - 0195-6108

IS - 1

ER -