On the optimization of imaging protocol for the mapping of cerebrovascular reactivity

Harshan Ravi, Binu P. Thomas, Shin Lei Peng, Hanli Liu, Hanzhang Lu

Research output: Contribution to journalArticlepeer-review

11 Scopus citations

Abstract

Background To devise an improved blood-oxygen-level-dependent (BOLD) imaging protocol for cerebrovascular reactivity (CVR) measurement that can remove a known artifact of negative values. Methods Theoretical and simulation studies were first performed to understand the biophysical mechanism of the negative CVR signals, through which improved BOLD sequence parameters were proposed. This was achieved by equating signal intensities between cerebrospinal fluid and blood, by means of shortening the echo time (TE) of the BOLD sequence. Then, 10 healthy volunteers were recruited to participate in an experimental study, in which we compared the CVR results of two versions of the optimized ("Opt1" and "Opt2") protocols with that of the standard protocol at 3 Tesla. Two sessions were performed for each subject to test the reproducibility of all three protocols. Results Experimental results demonstrated that the optimized protocols resulted in elimination of negative-CVR voxels. Quantitative CVR results were compared across protocols, which show that the optimized protocols yielded smaller CVR values (Opt1: 0.16 ± 0.01 %BOLD/mmHg CO2; Opt2: 0.15 ± 0.01 %BOLD/mmHg CO2) than (P < 0.001) the standard protocol (0.21 ± 0.01 %BOLD/mmHg CO2), but the CNR was comparable (P = 0.1) to the standard protocol. The coefficient-of-variation between repetitions was found to be 5.6 ± 1.4%, 6.3 ± 1.6%, and 6.9 ± 0.9% for the three protocols, but there were no significant differences (P = 0.65). Conclusion Based on the theoretical and experimental results obtained from this study, we suggest that the use of a TE shorter than those used in fMRI is necessary to minimize negative artifact in CVR results. J. MAGN. RESON. IMAGING 2016;43:661-668.

Original languageEnglish (US)
Pages (from-to)661-668
Number of pages8
JournalJournal of Magnetic Resonance Imaging
Volume43
Issue number3
DOIs
StatePublished - Mar 1 2016

Keywords

  • CO
  • blood vessels
  • brain
  • cerebrospinal fluid
  • cerebrovascular reactivity
  • gas inhalation

ASJC Scopus subject areas

  • Radiology Nuclear Medicine and imaging

Fingerprint

Dive into the research topics of 'On the optimization of imaging protocol for the mapping of cerebrovascular reactivity'. Together they form a unique fingerprint.

Cite this