Musical sound quality impairments in Cochlear Implant (CI) users as a function of limited high-frequency perception

Alexis T. Roy, Patpong Jiradejvong, Courtney Carver, Charles J. Limb

Research output: Contribution to journalArticle

Abstract

The purpose of this study was to (a) apply the musical sound quality assessment method, Cochlear Implant-MUltiple Stimulus with Hidden Reference and Anchor (CI-MUSHRA), to quantify musical sound quality deficits in CI (cochlear implant) users with respect to high-frequency loss, and (b) assess possible correlations between CI-MUSHRA performance and self-reported musical sound quality, as assessed by more traditional rating scales. Five versions of real-world musical stimuli were created: 8-,4-, and 2-kHz low-pass-filtered (LPF) versions with increasing high-frequency removal, a composite stimulus containing a 1-kHz LPF-filtered version and white noise ("anchor"), and an unaltered version ("hidden reference"). Using the CI-MUSHRA methodology, these versions were simultaneously presented to participants in addition to a labeled reference. Participants listened to all versions and provided ratings based on a 100-point scale that reflected perceived sound quality difference among the versions. A total of 25 musical stimuli were tested. As comparison measures, participants completed four Visual Analogue Scales (VAS) to assess musical sound quality. Overall, compared to normal hearing (NH) listeners, CI users demonstrated an impaired ability to discriminate between unaltered and altered musical stimuli with variable amounts of high-frequency information removed. Performance using CI-MUSHRA to evaluate this parameter did not correlate to measurements of musical sound quality, as assessed by VAS. This study identified high-frequency loss as one acoustic parameter contributing to overall CI-mediated musical sound quality limitations. CI-MUSHRA provided a quantitative assessment of musical sound quality. This method offers the potential to quantify CI impairments of many different acoustic parameters related to musical sound quality in the future.

Original languageEnglish (US)
Pages (from-to)191-200
Number of pages10
JournalTrends in Amplification
Volume16
Issue number4
DOIs
StatePublished - Dec 2012

Fingerprint

Cochlear Implants
Visual Analog Scale
Acoustics
Aptitude
Hearing

Keywords

  • cochlear implants
  • music perception
  • sound quality

ASJC Scopus subject areas

  • Speech and Hearing

Cite this

Musical sound quality impairments in Cochlear Implant (CI) users as a function of limited high-frequency perception. / Roy, Alexis T.; Jiradejvong, Patpong; Carver, Courtney; Limb, Charles J.

In: Trends in Amplification, Vol. 16, No. 4, 12.2012, p. 191-200.

Research output: Contribution to journalArticle

@article{b729a3031a7b461abf097d55cf9b81b1,
title = "Musical sound quality impairments in Cochlear Implant (CI) users as a function of limited high-frequency perception",
abstract = "The purpose of this study was to (a) apply the musical sound quality assessment method, Cochlear Implant-MUltiple Stimulus with Hidden Reference and Anchor (CI-MUSHRA), to quantify musical sound quality deficits in CI (cochlear implant) users with respect to high-frequency loss, and (b) assess possible correlations between CI-MUSHRA performance and self-reported musical sound quality, as assessed by more traditional rating scales. Five versions of real-world musical stimuli were created: 8-,4-, and 2-kHz low-pass-filtered (LPF) versions with increasing high-frequency removal, a composite stimulus containing a 1-kHz LPF-filtered version and white noise ({"}anchor{"}), and an unaltered version ({"}hidden reference{"}). Using the CI-MUSHRA methodology, these versions were simultaneously presented to participants in addition to a labeled reference. Participants listened to all versions and provided ratings based on a 100-point scale that reflected perceived sound quality difference among the versions. A total of 25 musical stimuli were tested. As comparison measures, participants completed four Visual Analogue Scales (VAS) to assess musical sound quality. Overall, compared to normal hearing (NH) listeners, CI users demonstrated an impaired ability to discriminate between unaltered and altered musical stimuli with variable amounts of high-frequency information removed. Performance using CI-MUSHRA to evaluate this parameter did not correlate to measurements of musical sound quality, as assessed by VAS. This study identified high-frequency loss as one acoustic parameter contributing to overall CI-mediated musical sound quality limitations. CI-MUSHRA provided a quantitative assessment of musical sound quality. This method offers the potential to quantify CI impairments of many different acoustic parameters related to musical sound quality in the future.",
keywords = "cochlear implants, music perception, sound quality",
author = "Roy, {Alexis T.} and Patpong Jiradejvong and Courtney Carver and Limb, {Charles J.}",
year = "2012",
month = "12",
doi = "10.1177/1084713812465493",
language = "English (US)",
volume = "16",
pages = "191--200",
journal = "Trends in hearing",
issn = "1084-7138",
publisher = "SAGE Publications Inc.",
number = "4",

}

TY - JOUR

T1 - Musical sound quality impairments in Cochlear Implant (CI) users as a function of limited high-frequency perception

AU - Roy, Alexis T.

AU - Jiradejvong, Patpong

AU - Carver, Courtney

AU - Limb, Charles J.

PY - 2012/12

Y1 - 2012/12

N2 - The purpose of this study was to (a) apply the musical sound quality assessment method, Cochlear Implant-MUltiple Stimulus with Hidden Reference and Anchor (CI-MUSHRA), to quantify musical sound quality deficits in CI (cochlear implant) users with respect to high-frequency loss, and (b) assess possible correlations between CI-MUSHRA performance and self-reported musical sound quality, as assessed by more traditional rating scales. Five versions of real-world musical stimuli were created: 8-,4-, and 2-kHz low-pass-filtered (LPF) versions with increasing high-frequency removal, a composite stimulus containing a 1-kHz LPF-filtered version and white noise ("anchor"), and an unaltered version ("hidden reference"). Using the CI-MUSHRA methodology, these versions were simultaneously presented to participants in addition to a labeled reference. Participants listened to all versions and provided ratings based on a 100-point scale that reflected perceived sound quality difference among the versions. A total of 25 musical stimuli were tested. As comparison measures, participants completed four Visual Analogue Scales (VAS) to assess musical sound quality. Overall, compared to normal hearing (NH) listeners, CI users demonstrated an impaired ability to discriminate between unaltered and altered musical stimuli with variable amounts of high-frequency information removed. Performance using CI-MUSHRA to evaluate this parameter did not correlate to measurements of musical sound quality, as assessed by VAS. This study identified high-frequency loss as one acoustic parameter contributing to overall CI-mediated musical sound quality limitations. CI-MUSHRA provided a quantitative assessment of musical sound quality. This method offers the potential to quantify CI impairments of many different acoustic parameters related to musical sound quality in the future.

AB - The purpose of this study was to (a) apply the musical sound quality assessment method, Cochlear Implant-MUltiple Stimulus with Hidden Reference and Anchor (CI-MUSHRA), to quantify musical sound quality deficits in CI (cochlear implant) users with respect to high-frequency loss, and (b) assess possible correlations between CI-MUSHRA performance and self-reported musical sound quality, as assessed by more traditional rating scales. Five versions of real-world musical stimuli were created: 8-,4-, and 2-kHz low-pass-filtered (LPF) versions with increasing high-frequency removal, a composite stimulus containing a 1-kHz LPF-filtered version and white noise ("anchor"), and an unaltered version ("hidden reference"). Using the CI-MUSHRA methodology, these versions were simultaneously presented to participants in addition to a labeled reference. Participants listened to all versions and provided ratings based on a 100-point scale that reflected perceived sound quality difference among the versions. A total of 25 musical stimuli were tested. As comparison measures, participants completed four Visual Analogue Scales (VAS) to assess musical sound quality. Overall, compared to normal hearing (NH) listeners, CI users demonstrated an impaired ability to discriminate between unaltered and altered musical stimuli with variable amounts of high-frequency information removed. Performance using CI-MUSHRA to evaluate this parameter did not correlate to measurements of musical sound quality, as assessed by VAS. This study identified high-frequency loss as one acoustic parameter contributing to overall CI-mediated musical sound quality limitations. CI-MUSHRA provided a quantitative assessment of musical sound quality. This method offers the potential to quantify CI impairments of many different acoustic parameters related to musical sound quality in the future.

KW - cochlear implants

KW - music perception

KW - sound quality

UR - http://www.scopus.com/inward/record.url?scp=84871599871&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=84871599871&partnerID=8YFLogxK

U2 - 10.1177/1084713812465493

DO - 10.1177/1084713812465493

M3 - Article

VL - 16

SP - 191

EP - 200

JO - Trends in hearing

JF - Trends in hearing

SN - 1084-7138

IS - 4

ER -