MRI dynamic range and its compatibility with signal transmission media

Refaat E. Gabr, Michael Schar, Arthur D. Edelstein, Dara Kraitchman, Paul A Bottomley, William A. Edelstein

Research output: Contribution to journalArticle

Abstract

As the number of MRI phased array coil elements grows, interactions among cables connecting them to the system receiver become increasingly problematic. Fiber optic or wireless links would reduce electromagnetic interference, but their dynamic range (DR) is generally less than that of coaxial cables. Raw MRI signals, however, have a large DR because of the high signal amplitude near the center of k-space. Here, we study DR in MRI in order to determine the compatibility of MRI multicoil imaging with non-coaxial cable signal transmission. Since raw signal data are routinely discarded, we have developed an improved method for estimating the DR of MRI signals from conventional magnitude images. Our results indicate that the DR of typical surface coil signals at 3 T for human subjects is less than 88 dB, even for three-dimensional acquisition protocols. Cardiac and spine coil arrays had a maximum DR of less than 75 dB and head coil arrays less than 88 dB. The DR derived from magnitude images is in good agreement with that measured from raw data. The results suggest that current analog fiber optic links, with a spurious-free DR of 60-70 dB at 500 kHz bandwidth, are not by themselves adequate for transmitting MRI data from volume or array coils with DR ∼90 dB. However, combining analog links with signal compression might make non-coaxial cable signal transmission viable.

Original languageEnglish (US)
Pages (from-to)137-145
Number of pages9
JournalJournal of Magnetic Resonance
Volume198
Issue number2
DOIs
StatePublished - Jun 2009

Fingerprint

signal transmission
Electromagnetic Phenomena
Magnetic resonance imaging
compatibility
dynamic range
Spine
Head
coils
cables
Cables
Fiber optics
fiber optics
analogs
coaxial cables
Coaxial cables
spine
electromagnetic interference
phased arrays
Signal interference
Telecommunication links

Keywords

  • Dynamic range
  • Fiber optic link
  • Magnetic resonance imaging
  • Magnitude image
  • MRI
  • Signal-to-noise ratio
  • Wireless link

ASJC Scopus subject areas

  • Nuclear and High Energy Physics
  • Biochemistry
  • Biophysics
  • Condensed Matter Physics

Cite this

MRI dynamic range and its compatibility with signal transmission media. / Gabr, Refaat E.; Schar, Michael; Edelstein, Arthur D.; Kraitchman, Dara; Bottomley, Paul A; Edelstein, William A.

In: Journal of Magnetic Resonance, Vol. 198, No. 2, 06.2009, p. 137-145.

Research output: Contribution to journalArticle

Gabr, Refaat E. ; Schar, Michael ; Edelstein, Arthur D. ; Kraitchman, Dara ; Bottomley, Paul A ; Edelstein, William A. / MRI dynamic range and its compatibility with signal transmission media. In: Journal of Magnetic Resonance. 2009 ; Vol. 198, No. 2. pp. 137-145.
@article{db72c995f1e74f7892cd7c95f1deb702,
title = "MRI dynamic range and its compatibility with signal transmission media",
abstract = "As the number of MRI phased array coil elements grows, interactions among cables connecting them to the system receiver become increasingly problematic. Fiber optic or wireless links would reduce electromagnetic interference, but their dynamic range (DR) is generally less than that of coaxial cables. Raw MRI signals, however, have a large DR because of the high signal amplitude near the center of k-space. Here, we study DR in MRI in order to determine the compatibility of MRI multicoil imaging with non-coaxial cable signal transmission. Since raw signal data are routinely discarded, we have developed an improved method for estimating the DR of MRI signals from conventional magnitude images. Our results indicate that the DR of typical surface coil signals at 3 T for human subjects is less than 88 dB, even for three-dimensional acquisition protocols. Cardiac and spine coil arrays had a maximum DR of less than 75 dB and head coil arrays less than 88 dB. The DR derived from magnitude images is in good agreement with that measured from raw data. The results suggest that current analog fiber optic links, with a spurious-free DR of 60-70 dB at 500 kHz bandwidth, are not by themselves adequate for transmitting MRI data from volume or array coils with DR ∼90 dB. However, combining analog links with signal compression might make non-coaxial cable signal transmission viable.",
keywords = "Dynamic range, Fiber optic link, Magnetic resonance imaging, Magnitude image, MRI, Signal-to-noise ratio, Wireless link",
author = "Gabr, {Refaat E.} and Michael Schar and Edelstein, {Arthur D.} and Dara Kraitchman and Bottomley, {Paul A} and Edelstein, {William A.}",
year = "2009",
month = "6",
doi = "10.1016/j.jmr.2009.01.037",
language = "English (US)",
volume = "198",
pages = "137--145",
journal = "Journal of Magnetic Resonance",
issn = "1090-7807",
publisher = "Academic Press Inc.",
number = "2",

}

TY - JOUR

T1 - MRI dynamic range and its compatibility with signal transmission media

AU - Gabr, Refaat E.

AU - Schar, Michael

AU - Edelstein, Arthur D.

AU - Kraitchman, Dara

AU - Bottomley, Paul A

AU - Edelstein, William A.

PY - 2009/6

Y1 - 2009/6

N2 - As the number of MRI phased array coil elements grows, interactions among cables connecting them to the system receiver become increasingly problematic. Fiber optic or wireless links would reduce electromagnetic interference, but their dynamic range (DR) is generally less than that of coaxial cables. Raw MRI signals, however, have a large DR because of the high signal amplitude near the center of k-space. Here, we study DR in MRI in order to determine the compatibility of MRI multicoil imaging with non-coaxial cable signal transmission. Since raw signal data are routinely discarded, we have developed an improved method for estimating the DR of MRI signals from conventional magnitude images. Our results indicate that the DR of typical surface coil signals at 3 T for human subjects is less than 88 dB, even for three-dimensional acquisition protocols. Cardiac and spine coil arrays had a maximum DR of less than 75 dB and head coil arrays less than 88 dB. The DR derived from magnitude images is in good agreement with that measured from raw data. The results suggest that current analog fiber optic links, with a spurious-free DR of 60-70 dB at 500 kHz bandwidth, are not by themselves adequate for transmitting MRI data from volume or array coils with DR ∼90 dB. However, combining analog links with signal compression might make non-coaxial cable signal transmission viable.

AB - As the number of MRI phased array coil elements grows, interactions among cables connecting them to the system receiver become increasingly problematic. Fiber optic or wireless links would reduce electromagnetic interference, but their dynamic range (DR) is generally less than that of coaxial cables. Raw MRI signals, however, have a large DR because of the high signal amplitude near the center of k-space. Here, we study DR in MRI in order to determine the compatibility of MRI multicoil imaging with non-coaxial cable signal transmission. Since raw signal data are routinely discarded, we have developed an improved method for estimating the DR of MRI signals from conventional magnitude images. Our results indicate that the DR of typical surface coil signals at 3 T for human subjects is less than 88 dB, even for three-dimensional acquisition protocols. Cardiac and spine coil arrays had a maximum DR of less than 75 dB and head coil arrays less than 88 dB. The DR derived from magnitude images is in good agreement with that measured from raw data. The results suggest that current analog fiber optic links, with a spurious-free DR of 60-70 dB at 500 kHz bandwidth, are not by themselves adequate for transmitting MRI data from volume or array coils with DR ∼90 dB. However, combining analog links with signal compression might make non-coaxial cable signal transmission viable.

KW - Dynamic range

KW - Fiber optic link

KW - Magnetic resonance imaging

KW - Magnitude image

KW - MRI

KW - Signal-to-noise ratio

KW - Wireless link

UR - http://www.scopus.com/inward/record.url?scp=67349256377&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=67349256377&partnerID=8YFLogxK

U2 - 10.1016/j.jmr.2009.01.037

DO - 10.1016/j.jmr.2009.01.037

M3 - Article

C2 - 19251444

AN - SCOPUS:67349256377

VL - 198

SP - 137

EP - 145

JO - Journal of Magnetic Resonance

JF - Journal of Magnetic Resonance

SN - 1090-7807

IS - 2

ER -