Miniature ball-tip optical fibers for use in thulium fiber laser ablation of kidney stones

Christopher R. Wilson, Luke A. Hardy, Joshua D. Kennedy, Pierce B. Irby, Nathaniel M. Fried

Research output: Contribution to journalArticlepeer-review

16 Scopus citations

Abstract

Optical fibers, consisting of 240-μm-core trunk fibers with rounded, 450-μm-diameter ball tips, are currently used during Holmium:YAG laser lithotripsy to reduce mechanical damage to the inner lining of the ureteroscope working channel during fiber insertion and prolong ureteroscope lifetime. Similarly, this study tests a smaller, 100-μm-core fiber with 300-μm-diameter ball tip during thulium fiber laser (TFL) lithotripsy. TFL was operated at a wavelength of 1908 nm, with 35-mJ pulse energy, 500-μs pulse duration, and 300-Hz pulse rate. Calcium oxalate/phosphate stone samples were weighed, laser procedure times were measured, and ablation rates were calculated for ball tip fibers, with comparison to bare tip fibers. Photographs of ball tips were taken before and after each procedure to track ball tip degradation and determine number of procedures completed before need for replacement. A high speed camera also recorded the cavitation bubble dynamics during TFL lithotripsy. Additionally, saline irrigation rates and ureteroscope deflection were measured with and without the presence of TFL fiber. There was no statistical difference (P > 0.05) between stone ablation rates for single-use ball tip fiber (1.3 ± 0.4 mg/s) (n = 10), multiple-use ball tip fiber (1=3 ± 0=5 mg/s) (n = 44), and conventional single-use bare tip fibers (1=3 ± 0=2 mg/s) (n = 10)= Ball tip durability varied widely, but fibers averaged greater than four stone procedures before failure, defined by rapid decline in stone ablation rates= Mechanical damage at the front surface of the ball tip was the limiting factor in fiber lifetime= The small fiber diameter did not significantly impact ureteroscope deflection or saline flow rates= The miniature ball tip fiber may provide a cost-effective design for safe fiber insertion through the ureteroscope working channel and into the ureter without risk of instrument damage or tissue perforation, and without compromising stone ablation efficiency during TFL lithotripsy.

Original languageEnglish (US)
Article number018003
JournalJournal of Biomedical Optics
Volume21
Issue number1
DOIs
StatePublished - Jan 1 2016
Externally publishedYes

Keywords

  • Ablation
  • Ball-tip fibers
  • Kidney stones
  • Lithotripsy
  • Thulium

ASJC Scopus subject areas

  • Biomedical Engineering
  • Biomaterials
  • Electronic, Optical and Magnetic Materials
  • Atomic and Molecular Physics, and Optics

Fingerprint

Dive into the research topics of 'Miniature ball-tip optical fibers for use in thulium fiber laser ablation of kidney stones'. Together they form a unique fingerprint.

Cite this