Microdosimetry of negative pions at LAMPF

H. I. Amols, John F Dicello, T. F. Lane

Research output: Contribution to journalArticle

Abstract

Lineal energy distributions and linear energy transfer (LET) spectra are being measured at the biomedical facility of this laboratory for a negative pion beam having an initial momentum of 168 MeV/c. The results show that the fraction of the dose for lineal energies greater than 50 keV/μm is approximately 2% in the plateau and approximately 12% at the Bragg peak. Preliminary data indicate that the high lineal energy (and high LET) component increases significantly in the region slightly downstream from the peak.

Original languageEnglish (US)
Pages (from-to)183-185
Number of pages3
JournalRadiology
Volume116
Issue number1
StatePublished - 1975
Externally publishedYes

Fingerprint

Mesons
Linear Energy Transfer

ASJC Scopus subject areas

  • Radiological and Ultrasound Technology

Cite this

Amols, H. I., Dicello, J. F., & Lane, T. F. (1975). Microdosimetry of negative pions at LAMPF. Radiology, 116(1), 183-185.

Microdosimetry of negative pions at LAMPF. / Amols, H. I.; Dicello, John F; Lane, T. F.

In: Radiology, Vol. 116, No. 1, 1975, p. 183-185.

Research output: Contribution to journalArticle

Amols, HI, Dicello, JF & Lane, TF 1975, 'Microdosimetry of negative pions at LAMPF', Radiology, vol. 116, no. 1, pp. 183-185.
Amols HI, Dicello JF, Lane TF. Microdosimetry of negative pions at LAMPF. Radiology. 1975;116(1):183-185.
Amols, H. I. ; Dicello, John F ; Lane, T. F. / Microdosimetry of negative pions at LAMPF. In: Radiology. 1975 ; Vol. 116, No. 1. pp. 183-185.
@article{7922738e99c341a69944bdab46e0c1e2,
title = "Microdosimetry of negative pions at LAMPF",
abstract = "Lineal energy distributions and linear energy transfer (LET) spectra are being measured at the biomedical facility of this laboratory for a negative pion beam having an initial momentum of 168 MeV/c. The results show that the fraction of the dose for lineal energies greater than 50 keV/μm is approximately 2{\%} in the plateau and approximately 12{\%} at the Bragg peak. Preliminary data indicate that the high lineal energy (and high LET) component increases significantly in the region slightly downstream from the peak.",
author = "Amols, {H. I.} and Dicello, {John F} and Lane, {T. F.}",
year = "1975",
language = "English (US)",
volume = "116",
pages = "183--185",
journal = "Radiology",
issn = "0033-8419",
publisher = "Radiological Society of North America Inc.",
number = "1",

}

TY - JOUR

T1 - Microdosimetry of negative pions at LAMPF

AU - Amols, H. I.

AU - Dicello, John F

AU - Lane, T. F.

PY - 1975

Y1 - 1975

N2 - Lineal energy distributions and linear energy transfer (LET) spectra are being measured at the biomedical facility of this laboratory for a negative pion beam having an initial momentum of 168 MeV/c. The results show that the fraction of the dose for lineal energies greater than 50 keV/μm is approximately 2% in the plateau and approximately 12% at the Bragg peak. Preliminary data indicate that the high lineal energy (and high LET) component increases significantly in the region slightly downstream from the peak.

AB - Lineal energy distributions and linear energy transfer (LET) spectra are being measured at the biomedical facility of this laboratory for a negative pion beam having an initial momentum of 168 MeV/c. The results show that the fraction of the dose for lineal energies greater than 50 keV/μm is approximately 2% in the plateau and approximately 12% at the Bragg peak. Preliminary data indicate that the high lineal energy (and high LET) component increases significantly in the region slightly downstream from the peak.

UR - http://www.scopus.com/inward/record.url?scp=0016593143&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=0016593143&partnerID=8YFLogxK

M3 - Article

C2 - 806097

AN - SCOPUS:0016593143

VL - 116

SP - 183

EP - 185

JO - Radiology

JF - Radiology

SN - 0033-8419

IS - 1