Following the first demonstrations of high‐mass analysis using time‐of‐flight matriz‐assisted laser desorption/ionization (MALDI) techniques by Hillenkamp,1,2 Tanaka3 and their co‐workers, there have been significant efforts in a number of laboratories to adapt the new methodology to Fourier‐transform mass Spectrometry (FTMS). The motivation fsor this research is obvious. Namely, it would be desirable to couple the unparalleled high mass resolution of FTMS4 with the extended mass range proveded by MALDI, paricularly for analysis of polymers and biomolecules. Unfortuanately, Prior to the presnt work, attempts to mate FTMS and MALDI have met with limited success. The highest mass matrix‐assisted laser‐desorption‐FTMS result previously obtained appears to be the unpublished low resolution spectrum of bovine insulin recently reported by russell co‐workers.5 We,6 Campana and co‐workes,7 and Hettich and Buchanan8,9 have had some sucess with MALDI‐FTMS of biomolecules with masses lower than 3000 Da.9 Fruthermore, with single exception of Campana's report of obtaining mass resolutiojn of 5000 for the moleculer ion of melittin,7 such spectra have not displayed high resolution. Here, we report successful development of MALDI‐FTMS, demonstrated with spectra obtained from a variety of high‐mass polymer and biomolecule samples, using 355nm radiation from an excimer‐pumped dye laser for desorption/ionization and sinapinic acid as matrix, Some of these spectra are of much higher mass resolution than is possible with current time‐of flight mass spectrometers.

Original languageEnglish (US)
Pages (from-to)239-241
Number of pages3
JournalRapid Communications in Mass Spectrometry
Volume6
Issue number4
DOIs
StatePublished - 1992

Fingerprint

Ionization
Mass spectrometry
Desorption
Biomolecules
Molecules
Lasers
Polymers
Melitten
Dye lasers
Mass spectrometers
Demonstrations
Ions
Insulin
Radiation

ASJC Scopus subject areas

  • Analytical Chemistry
  • Spectroscopy
  • Organic Chemistry

Cite this

Matrix‐assisted laser desorption/ionization of high‐mass molecules by Fourier‐transform mass spectrometry. / Castro, John A.; Köster, Claus; Wilkins, Charles; Cotter, Robert J.

In: Rapid Communications in Mass Spectrometry, Vol. 6, No. 4, 1992, p. 239-241.

Research output: Contribution to journalArticle

@article{6e7e5a99e46e4a49afc0f0c232a46ad8,
title = "Matrix‐assisted laser desorption/ionization of high‐mass molecules by Fourier‐transform mass spectrometry",
abstract = "Following the first demonstrations of high‐mass analysis using time‐of‐flight matriz‐assisted laser desorption/ionization (MALDI) techniques by Hillenkamp,1,2 Tanaka3 and their co‐workers, there have been significant efforts in a number of laboratories to adapt the new methodology to Fourier‐transform mass Spectrometry (FTMS). The motivation fsor this research is obvious. Namely, it would be desirable to couple the unparalleled high mass resolution of FTMS4 with the extended mass range proveded by MALDI, paricularly for analysis of polymers and biomolecules. Unfortuanately, Prior to the presnt work, attempts to mate FTMS and MALDI have met with limited success. The highest mass matrix‐assisted laser‐desorption‐FTMS result previously obtained appears to be the unpublished low resolution spectrum of bovine insulin recently reported by russell co‐workers.5 We,6 Campana and co‐workes,7 and Hettich and Buchanan8,9 have had some sucess with MALDI‐FTMS of biomolecules with masses lower than 3000 Da.9 Fruthermore, with single exception of Campana's report of obtaining mass resolutiojn of 5000 for the moleculer ion of melittin,7 such spectra have not displayed high resolution. Here, we report successful development of MALDI‐FTMS, demonstrated with spectra obtained from a variety of high‐mass polymer and biomolecule samples, using 355nm radiation from an excimer‐pumped dye laser for desorption/ionization and sinapinic acid as matrix, Some of these spectra are of much higher mass resolution than is possible with current time‐of flight mass spectrometers.",
author = "Castro, {John A.} and Claus K{\"o}ster and Charles Wilkins and Cotter, {Robert J.}",
year = "1992",
doi = "10.1002/rcm.1290060403",
language = "English (US)",
volume = "6",
pages = "239--241",
journal = "Rapid Communications in Mass Spectrometry",
issn = "0951-4198",
publisher = "John Wiley and Sons Ltd",
number = "4",

}

TY - JOUR

T1 - Matrix‐assisted laser desorption/ionization of high‐mass molecules by Fourier‐transform mass spectrometry

AU - Castro, John A.

AU - Köster, Claus

AU - Wilkins, Charles

AU - Cotter, Robert J.

PY - 1992

Y1 - 1992

N2 - Following the first demonstrations of high‐mass analysis using time‐of‐flight matriz‐assisted laser desorption/ionization (MALDI) techniques by Hillenkamp,1,2 Tanaka3 and their co‐workers, there have been significant efforts in a number of laboratories to adapt the new methodology to Fourier‐transform mass Spectrometry (FTMS). The motivation fsor this research is obvious. Namely, it would be desirable to couple the unparalleled high mass resolution of FTMS4 with the extended mass range proveded by MALDI, paricularly for analysis of polymers and biomolecules. Unfortuanately, Prior to the presnt work, attempts to mate FTMS and MALDI have met with limited success. The highest mass matrix‐assisted laser‐desorption‐FTMS result previously obtained appears to be the unpublished low resolution spectrum of bovine insulin recently reported by russell co‐workers.5 We,6 Campana and co‐workes,7 and Hettich and Buchanan8,9 have had some sucess with MALDI‐FTMS of biomolecules with masses lower than 3000 Da.9 Fruthermore, with single exception of Campana's report of obtaining mass resolutiojn of 5000 for the moleculer ion of melittin,7 such spectra have not displayed high resolution. Here, we report successful development of MALDI‐FTMS, demonstrated with spectra obtained from a variety of high‐mass polymer and biomolecule samples, using 355nm radiation from an excimer‐pumped dye laser for desorption/ionization and sinapinic acid as matrix, Some of these spectra are of much higher mass resolution than is possible with current time‐of flight mass spectrometers.

AB - Following the first demonstrations of high‐mass analysis using time‐of‐flight matriz‐assisted laser desorption/ionization (MALDI) techniques by Hillenkamp,1,2 Tanaka3 and their co‐workers, there have been significant efforts in a number of laboratories to adapt the new methodology to Fourier‐transform mass Spectrometry (FTMS). The motivation fsor this research is obvious. Namely, it would be desirable to couple the unparalleled high mass resolution of FTMS4 with the extended mass range proveded by MALDI, paricularly for analysis of polymers and biomolecules. Unfortuanately, Prior to the presnt work, attempts to mate FTMS and MALDI have met with limited success. The highest mass matrix‐assisted laser‐desorption‐FTMS result previously obtained appears to be the unpublished low resolution spectrum of bovine insulin recently reported by russell co‐workers.5 We,6 Campana and co‐workes,7 and Hettich and Buchanan8,9 have had some sucess with MALDI‐FTMS of biomolecules with masses lower than 3000 Da.9 Fruthermore, with single exception of Campana's report of obtaining mass resolutiojn of 5000 for the moleculer ion of melittin,7 such spectra have not displayed high resolution. Here, we report successful development of MALDI‐FTMS, demonstrated with spectra obtained from a variety of high‐mass polymer and biomolecule samples, using 355nm radiation from an excimer‐pumped dye laser for desorption/ionization and sinapinic acid as matrix, Some of these spectra are of much higher mass resolution than is possible with current time‐of flight mass spectrometers.

UR - http://www.scopus.com/inward/record.url?scp=0026842106&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=0026842106&partnerID=8YFLogxK

U2 - 10.1002/rcm.1290060403

DO - 10.1002/rcm.1290060403

M3 - Article

C2 - 1315178

AN - SCOPUS:0026842106

VL - 6

SP - 239

EP - 241

JO - Rapid Communications in Mass Spectrometry

JF - Rapid Communications in Mass Spectrometry

SN - 0951-4198

IS - 4

ER -