Management of Nonmagnetic Intraocular Foreign Bodies: A New Approach With the Aid of Diagnostic X-ray Spectrometry

Michael Belkin, Ran Zeimer, Arye Weinreb, Ezra Loewinger, Zvi Kalman

Research output: Contribution to journalArticle

Abstract

A new approach is suggested for the management of nonmagnetic intraocular foreign bodies. This approach is based on diagnostic x-ray spectrometry, which is capable of detecting noninvasively the dissolution of metallic intraocular foreign bodies. As long as no copper dissolution is observed, foreign bodies of reasonable size are left in the eye and extraction is recommended whenever a persisting copper dissolution is detected. Of the 32 patients examined and followed up, 23 did not show any copper dissolution. The majority of these patients, one of whom has retained a foreign body for 28 years, have satisfactory visual functions. Of the nine patients in whom copper dissolution was observed, five were operated on. In three of the remaining four patients, the operation was delayed and the dissolution was found to be temporary. These patients retained good visual functions.

Original languageEnglish (US)
Pages (from-to)106-108
Number of pages3
JournalArchives of Ophthalmology
Volume97
Issue number1
DOIs
StatePublished - 1979
Externally publishedYes

Fingerprint

Foreign Bodies
Radiography
Spectrum Analysis
Copper
Body Size
X-Rays

ASJC Scopus subject areas

  • Ophthalmology

Cite this

Management of Nonmagnetic Intraocular Foreign Bodies : A New Approach With the Aid of Diagnostic X-ray Spectrometry. / Belkin, Michael; Zeimer, Ran; Weinreb, Arye; Loewinger, Ezra; Kalman, Zvi.

In: Archives of Ophthalmology, Vol. 97, No. 1, 1979, p. 106-108.

Research output: Contribution to journalArticle

Belkin, Michael ; Zeimer, Ran ; Weinreb, Arye ; Loewinger, Ezra ; Kalman, Zvi. / Management of Nonmagnetic Intraocular Foreign Bodies : A New Approach With the Aid of Diagnostic X-ray Spectrometry. In: Archives of Ophthalmology. 1979 ; Vol. 97, No. 1. pp. 106-108.
@article{f3300c4da4e4422fa401735ffa438633,
title = "Management of Nonmagnetic Intraocular Foreign Bodies: A New Approach With the Aid of Diagnostic X-ray Spectrometry",
abstract = "A new approach is suggested for the management of nonmagnetic intraocular foreign bodies. This approach is based on diagnostic x-ray spectrometry, which is capable of detecting noninvasively the dissolution of metallic intraocular foreign bodies. As long as no copper dissolution is observed, foreign bodies of reasonable size are left in the eye and extraction is recommended whenever a persisting copper dissolution is detected. Of the 32 patients examined and followed up, 23 did not show any copper dissolution. The majority of these patients, one of whom has retained a foreign body for 28 years, have satisfactory visual functions. Of the nine patients in whom copper dissolution was observed, five were operated on. In three of the remaining four patients, the operation was delayed and the dissolution was found to be temporary. These patients retained good visual functions.",
author = "Michael Belkin and Ran Zeimer and Arye Weinreb and Ezra Loewinger and Zvi Kalman",
year = "1979",
doi = "10.1001/archopht.1979.01020010046011",
language = "English (US)",
volume = "97",
pages = "106--108",
journal = "JAMA Ophthalmology",
issn = "2168-6165",
publisher = "American Medical Association",
number = "1",

}

TY - JOUR

T1 - Management of Nonmagnetic Intraocular Foreign Bodies

T2 - A New Approach With the Aid of Diagnostic X-ray Spectrometry

AU - Belkin, Michael

AU - Zeimer, Ran

AU - Weinreb, Arye

AU - Loewinger, Ezra

AU - Kalman, Zvi

PY - 1979

Y1 - 1979

N2 - A new approach is suggested for the management of nonmagnetic intraocular foreign bodies. This approach is based on diagnostic x-ray spectrometry, which is capable of detecting noninvasively the dissolution of metallic intraocular foreign bodies. As long as no copper dissolution is observed, foreign bodies of reasonable size are left in the eye and extraction is recommended whenever a persisting copper dissolution is detected. Of the 32 patients examined and followed up, 23 did not show any copper dissolution. The majority of these patients, one of whom has retained a foreign body for 28 years, have satisfactory visual functions. Of the nine patients in whom copper dissolution was observed, five were operated on. In three of the remaining four patients, the operation was delayed and the dissolution was found to be temporary. These patients retained good visual functions.

AB - A new approach is suggested for the management of nonmagnetic intraocular foreign bodies. This approach is based on diagnostic x-ray spectrometry, which is capable of detecting noninvasively the dissolution of metallic intraocular foreign bodies. As long as no copper dissolution is observed, foreign bodies of reasonable size are left in the eye and extraction is recommended whenever a persisting copper dissolution is detected. Of the 32 patients examined and followed up, 23 did not show any copper dissolution. The majority of these patients, one of whom has retained a foreign body for 28 years, have satisfactory visual functions. Of the nine patients in whom copper dissolution was observed, five were operated on. In three of the remaining four patients, the operation was delayed and the dissolution was found to be temporary. These patients retained good visual functions.

UR - http://www.scopus.com/inward/record.url?scp=0018304370&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=0018304370&partnerID=8YFLogxK

U2 - 10.1001/archopht.1979.01020010046011

DO - 10.1001/archopht.1979.01020010046011

M3 - Article

C2 - 758886

AN - SCOPUS:0018304370

VL - 97

SP - 106

EP - 108

JO - JAMA Ophthalmology

JF - JAMA Ophthalmology

SN - 2168-6165

IS - 1