Magnetic resonance imaging of children without sedation

Preparation with simulation

David R. Rosenberg, John A. Sweeney, Joseph S Gillen, Jae Kim, Michael J. Varanelli, Kirsten M. O'Hearn, Patricia A. Erb, Denise Davis, Keith R. Thulborn

Research output: Contribution to journalArticle

Abstract

Objective: It was hypothesized that a scanner simulator that replicates the magnetic resonance imaging (MRI) environment could be used to prepare pediatric subjects for successful completion of a diagnostic-quality MRI examination without pharmacological sedation. Method: Sixteen healthy children, 6 to 17 years of age, were matched for age and sex with 16 psychotropic medication-naive children with obsessive-compulsive disorder. Distress was measured throughout simulation and scanning procedures using heart rate and a self-report distress scale. Ten healthy children, 6 to 17 years of age, also underwent the same actual MRI scanning procedure but did not undergo the simulation scanning procedure. Results: Significant decreases in heart rate and self-reported distress level were observed in all subjects during the simulator session that were maintained to the end of the actual scanner experience. All subjects successfully completed MRI examinations without chemical restraint. Subjects who were not trained in the simulator had higher heart rates and self-reported distress levels in the actual scanner than did simulation-trained subjects. Conclusions: Simulation without pharmacological sedation successfully prepared pediatric subjects in this pilot study for high-quality MRI studies. Subject preparation may be an alternative procedure to sedation for routine MRI examination in healthy and anxious children 6 years of age and older.

Original languageEnglish (US)
Pages (from-to)853-859
Number of pages7
JournalJournal of the American Academy of Child and Adolescent Psychiatry
Volume36
Issue number6
DOIs
StatePublished - Jun 1997
Externally publishedYes

Fingerprint

Magnetic Resonance Imaging
Heart Rate
Pharmacology
Pediatrics
Obsessive-Compulsive Disorder
Self Report

Keywords

  • Magnetic resonance imaging
  • Pediatric
  • Pharmacological sedation

ASJC Scopus subject areas

  • Psychiatry and Mental health
  • Developmental and Educational Psychology

Cite this

Magnetic resonance imaging of children without sedation : Preparation with simulation. / Rosenberg, David R.; Sweeney, John A.; Gillen, Joseph S; Kim, Jae; Varanelli, Michael J.; O'Hearn, Kirsten M.; Erb, Patricia A.; Davis, Denise; Thulborn, Keith R.

In: Journal of the American Academy of Child and Adolescent Psychiatry, Vol. 36, No. 6, 06.1997, p. 853-859.

Research output: Contribution to journalArticle

Rosenberg, David R. ; Sweeney, John A. ; Gillen, Joseph S ; Kim, Jae ; Varanelli, Michael J. ; O'Hearn, Kirsten M. ; Erb, Patricia A. ; Davis, Denise ; Thulborn, Keith R. / Magnetic resonance imaging of children without sedation : Preparation with simulation. In: Journal of the American Academy of Child and Adolescent Psychiatry. 1997 ; Vol. 36, No. 6. pp. 853-859.
@article{3283d6b42ebe4cc88f426ba4a6542537,
title = "Magnetic resonance imaging of children without sedation: Preparation with simulation",
abstract = "Objective: It was hypothesized that a scanner simulator that replicates the magnetic resonance imaging (MRI) environment could be used to prepare pediatric subjects for successful completion of a diagnostic-quality MRI examination without pharmacological sedation. Method: Sixteen healthy children, 6 to 17 years of age, were matched for age and sex with 16 psychotropic medication-naive children with obsessive-compulsive disorder. Distress was measured throughout simulation and scanning procedures using heart rate and a self-report distress scale. Ten healthy children, 6 to 17 years of age, also underwent the same actual MRI scanning procedure but did not undergo the simulation scanning procedure. Results: Significant decreases in heart rate and self-reported distress level were observed in all subjects during the simulator session that were maintained to the end of the actual scanner experience. All subjects successfully completed MRI examinations without chemical restraint. Subjects who were not trained in the simulator had higher heart rates and self-reported distress levels in the actual scanner than did simulation-trained subjects. Conclusions: Simulation without pharmacological sedation successfully prepared pediatric subjects in this pilot study for high-quality MRI studies. Subject preparation may be an alternative procedure to sedation for routine MRI examination in healthy and anxious children 6 years of age and older.",
keywords = "Magnetic resonance imaging, Pediatric, Pharmacological sedation",
author = "Rosenberg, {David R.} and Sweeney, {John A.} and Gillen, {Joseph S} and Jae Kim and Varanelli, {Michael J.} and O'Hearn, {Kirsten M.} and Erb, {Patricia A.} and Denise Davis and Thulborn, {Keith R.}",
year = "1997",
month = "6",
doi = "10.1097/00004583-199706000-00024",
language = "English (US)",
volume = "36",
pages = "853--859",
journal = "Journal of the American Academy of Child and Adolescent Psychiatry",
issn = "0890-8567",
publisher = "Elsevier Limited",
number = "6",

}

TY - JOUR

T1 - Magnetic resonance imaging of children without sedation

T2 - Preparation with simulation

AU - Rosenberg, David R.

AU - Sweeney, John A.

AU - Gillen, Joseph S

AU - Kim, Jae

AU - Varanelli, Michael J.

AU - O'Hearn, Kirsten M.

AU - Erb, Patricia A.

AU - Davis, Denise

AU - Thulborn, Keith R.

PY - 1997/6

Y1 - 1997/6

N2 - Objective: It was hypothesized that a scanner simulator that replicates the magnetic resonance imaging (MRI) environment could be used to prepare pediatric subjects for successful completion of a diagnostic-quality MRI examination without pharmacological sedation. Method: Sixteen healthy children, 6 to 17 years of age, were matched for age and sex with 16 psychotropic medication-naive children with obsessive-compulsive disorder. Distress was measured throughout simulation and scanning procedures using heart rate and a self-report distress scale. Ten healthy children, 6 to 17 years of age, also underwent the same actual MRI scanning procedure but did not undergo the simulation scanning procedure. Results: Significant decreases in heart rate and self-reported distress level were observed in all subjects during the simulator session that were maintained to the end of the actual scanner experience. All subjects successfully completed MRI examinations without chemical restraint. Subjects who were not trained in the simulator had higher heart rates and self-reported distress levels in the actual scanner than did simulation-trained subjects. Conclusions: Simulation without pharmacological sedation successfully prepared pediatric subjects in this pilot study for high-quality MRI studies. Subject preparation may be an alternative procedure to sedation for routine MRI examination in healthy and anxious children 6 years of age and older.

AB - Objective: It was hypothesized that a scanner simulator that replicates the magnetic resonance imaging (MRI) environment could be used to prepare pediatric subjects for successful completion of a diagnostic-quality MRI examination without pharmacological sedation. Method: Sixteen healthy children, 6 to 17 years of age, were matched for age and sex with 16 psychotropic medication-naive children with obsessive-compulsive disorder. Distress was measured throughout simulation and scanning procedures using heart rate and a self-report distress scale. Ten healthy children, 6 to 17 years of age, also underwent the same actual MRI scanning procedure but did not undergo the simulation scanning procedure. Results: Significant decreases in heart rate and self-reported distress level were observed in all subjects during the simulator session that were maintained to the end of the actual scanner experience. All subjects successfully completed MRI examinations without chemical restraint. Subjects who were not trained in the simulator had higher heart rates and self-reported distress levels in the actual scanner than did simulation-trained subjects. Conclusions: Simulation without pharmacological sedation successfully prepared pediatric subjects in this pilot study for high-quality MRI studies. Subject preparation may be an alternative procedure to sedation for routine MRI examination in healthy and anxious children 6 years of age and older.

KW - Magnetic resonance imaging

KW - Pediatric

KW - Pharmacological sedation

UR - http://www.scopus.com/inward/record.url?scp=0031002399&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=0031002399&partnerID=8YFLogxK

U2 - 10.1097/00004583-199706000-00024

DO - 10.1097/00004583-199706000-00024

M3 - Article

VL - 36

SP - 853

EP - 859

JO - Journal of the American Academy of Child and Adolescent Psychiatry

JF - Journal of the American Academy of Child and Adolescent Psychiatry

SN - 0890-8567

IS - 6

ER -