Lysis of intracerebral hematoma with stereotactically implanted tissue plasminogen activator polymers in a rabbit model

Quoc-Anh Thai, Gustavo Pradilla, Federico G. Legnani, Ryan M. Kretzer, Wesley Hsu, Rafael J. Tamargo

Research output: Contribution to journalArticlepeer-review

10 Scopus citations

Abstract

Object. Currently no adequate surgical treatment exists for spontaneous intracerebral hemorrhage (ICH). Implantable polymers can be used effectively to deliver therapeutic agents to the local site of the pathological process, thus reducing adverse systemic effects. The authors report the use of stereotactically implanted polymers loaded with tissue plasminogen activator (tPA) to induce lysis of ICH in a rabbit model. Methods. Ethylene vinyl acetate (EVAc) polymers were loaded with bovine serum albumin (BSA) only or with BSA plus tPA. In vitro pharmacokinetic (three polymers) and thrombolysis (12 polymers) studies were performed. For the in vivo study, 12 rabbits were fixed in a stereotactic frame, and 0.2 ml of clotted autologous blood was injected into the right frontal lobe parenchyma. After 20 minutes, control BSA polymers were stereotactically implanted at the hemorrhage site in six rabbits, and experimental BSA plus tPA polymers were implanted in six rabbits. Animals were killed at 3 days, and blood clot volume was assessed. The pharmacokinetic study showed release of 146 ng of tPA over 3 days. The tPA activity correlated with in vitro thrombolysis. In the in vivo study, the six animals treated with tPA polymers had a mean (± standard error of the mean [SEM]) thrombus volume of 1.43 ± 0.29 mm3 at 3 days, whereas the six animals treated with blank (BSA-only) polymers had a mean (± SEM) thrombus volume of 19.99 ± 3.74 mm3 (p < 0.001). Conclusions. Ethylene vinyl acetate polymers release tPA over the course of 3 days. Stereotactic implantation of tPA-loaded EVAc polymers significantly reduced ICH volume. Polymers loaded with tPA may be useful clinically for lysis of ICH without the side effects of systemic administration of tPA.

Original languageEnglish (US)
Pages (from-to)424-429
Number of pages6
JournalJournal of neurosurgery
Volume105
Issue number3
DOIs
StatePublished - 2006

Keywords

  • Controlled-release polymer
  • Intracerebral hematoma
  • Intracerebral hemorrhage
  • Rabbit
  • Stereotactic targeting
  • Tissue plasminogen activator

ASJC Scopus subject areas

  • Surgery
  • Clinical Neurology

Fingerprint

Dive into the research topics of 'Lysis of intracerebral hematoma with stereotactically implanted tissue plasminogen activator polymers in a rabbit model'. Together they form a unique fingerprint.

Cite this